机组,批次,点位,点位描述,级,缸,异常类型,开始小时,结束小时,持续自然小时数,有效小时数,是否显著,最小值,最大值,中位数,同级基准中位,原因 4号机,56,YSJ_10,一级2#缸排气温度,一级,2#,停机/通道异常,2025-10-20 03:00:00,2025-10-20 04:00:00,2,2,是,0.0,0.0,0.0,106.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_10,一级2#缸排气温度,一级,2#,停机/通道异常,2025-10-21 00:00:00,2025-10-21 01:00:00,2,2,是,0.0,0.0,0.0,106.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-10-22 05:00:00,2025-10-22 07:00:00,3,2,是,0.0,0.0,0.0,108.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2025-10-22 10:00:00,2025-10-22 11:00:00,2,2,是,0.0,0.0,0.0,104.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2025-10-22 21:00:00,2025-10-22 22:00:00,2,2,是,0.0,0.0,0.0,109.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-10-23 04:00:00,2025-10-23 05:00:00,2,2,是,0.0,0.0,0.0,111.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-10-23 15:00:00,2025-10-23 18:00:00,4,2,是,0.0,0.0,0.0,112.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,通道冻值,2025-10-23 20:00:00,2025-10-24 07:00:00,12,12,是,104.0,104.05,104.0,107.9,单通道长期不变而同级其他缸在变化,按冻值处理 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2025-10-24 19:00:00,2025-10-26 08:00:00,38,31,是,0.0,104.07,104.0,107.5,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2025-10-25 05:00:00,2025-10-25 07:00:00,3,2,是,0.0,0.0,0.0,105.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_14,二级2#缸排气温度,二级,2#,停机/通道异常,2025-11-04 21:00:00,2025-11-04 22:00:00,2,2,是,0.0,0.0,0.0,107.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-06 22:00:00,2025-11-06 22:00:00,1,1,是,0.0,0.0,0.0,101.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-07 15:00:00,2025-11-07 17:00:00,3,2,是,0.0,0.0,0.0,102.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-07 17:00:00,2025-11-07 18:00:00,2,2,是,0.0,0.0,0.0,102.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-08 22:00:00,2025-11-08 22:00:00,1,1,是,0.0,0.0,0.0,104.52,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-09 18:00:00,2025-11-09 19:00:00,2,2,是,0.0,0.0,0.0,101.52,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-10 21:00:00,2025-11-10 22:00:00,2,2,是,0.0,0.0,0.0,102.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2025-11-11 11:00:00,2025-11-11 12:00:00,2,2,是,0.0,0.0,0.0,113.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-12 07:00:00,2025-11-12 08:00:00,2,2,是,0.0,0.0,0.0,104.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_10,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-16 05:00:00,2025-11-16 07:00:00,3,2,是,0.0,0.0,0.0,100.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-16 08:00:00,2025-11-16 10:00:00,3,2,是,0.0,0.0,0.0,106.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-17 18:00:00,2025-11-17 19:00:00,2,2,是,0.0,0.0,0.0,100.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2025-11-18 00:00:00,2025-11-18 01:00:00,2,2,是,0.0,0.0,0.0,93.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,101.97,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 4号机,56,YSJ_10,一级2#缸排气温度,一级,2#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,100.92,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,102.68,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,107.44,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 4号机,56,YSJ_14,二级2#缸排气温度,二级,2#,停机/通道异常,2025-11-19 15:00:00,2025-11-19 19:00:00,5,3,是,-0.0,-0.0,0.0,104.71,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,101.55,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-20 08:00:00,2025-11-20 10:00:00,3,2,是,0.0,0.0,0.0,106.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-24 19:00:00,2025-11-24 21:00:00,3,2,是,0.0,0.0,0.0,104.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-12-07 17:00:00,2025-12-07 18:00:00,2,2,是,0.0,0.0,0.0,112.1,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-12-24 12:00:00,2025-12-24 14:00:00,3,2,是,0.0,0.0,0.0,105.34,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2025-12-24 21:00:00,2025-12-24 22:00:00,2,2,是,0.0,0.0,0.0,96.99,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_10,一级2#缸排气温度,一级,2#,停机/通道异常,2025-12-25 21:00:00,2025-12-25 22:00:00,2,2,是,0.0,0.0,0.0,92.94,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2025-12-27 08:00:00,2025-12-27 10:00:00,3,2,是,0.0,0.0,0.0,96.52,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2025-12-27 18:00:00,2025-12-27 19:00:00,2,2,是,0.0,0.0,0.0,97.61,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_14,二级2#缸排气温度,二级,2#,停机/通道异常,2026-01-01 00:00:00,2026-01-01 01:00:00,2,2,是,0.0,0.0,0.0,95.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-01-01 01:00:00,2026-01-01 03:00:00,3,2,是,0.0,0.0,0.0,94.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-01-03 04:00:00,2026-01-03 05:00:00,2,2,是,0.0,0.0,0.0,99.46,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2026-01-04 17:00:00,2026-01-04 18:00:00,2,2,是,0.0,0.0,0.0,97.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_14,二级2#缸排气温度,二级,2#,停机/通道异常,2026-01-06 11:00:00,2026-01-06 12:00:00,2,2,是,0.0,0.0,0.0,98.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-06 21:00:00,2026-01-06 22:00:00,2,2,是,0.0,0.0,0.0,95.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-07 14:00:00,2026-01-07 15:00:00,2,2,是,0.0,0.0,0.0,96.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-01-07 21:00:00,2026-01-08 01:00:00,5,4,是,0.0,0.0,0.0,94.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-08 17:00:00,2026-01-08 18:00:00,2,2,是,0.0,0.0,0.0,96.93,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_14,二级2#缸排气温度,二级,2#,通道骤降,2026-01-09 13:00:00,2026-01-09 13:00:00,1,1,否,86.0,86.0,86.0,106.36,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-01-15 19:00:00,2026-01-15 21:00:00,3,2,是,0.0,0.0,0.0,106.1,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2026-01-16 01:00:00,2026-01-16 03:00:00,3,2,是,0.0,0.0,0.0,96.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_10,一级2#缸排气温度,一级,2#,停机/通道异常,2026-01-17 00:00:00,2026-01-17 07:00:00,8,4,是,0.0,0.0,0.0,98.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2026-01-17 18:00:00,2026-01-18 15:00:00,22,21,是,0.0,96.0,96.0,97.97,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-01-17 21:00:00,2026-01-17 22:00:00,2,2,是,0.0,0.0,0.0,97.5,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,通道冻值,2026-01-18 21:00:00,2026-01-19 08:00:00,12,12,是,97.0,97.09,97.0,98.0,单通道长期不变而同级其他缸在变化,按冻值处理 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-01-19 19:00:00,2026-01-19 21:00:00,3,2,是,0.0,0.0,0.0,92.5,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-01-21 10:00:00,2026-01-21 11:00:00,2,2,是,0.0,0.0,0.0,91.02,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-01-22 11:00:00,2026-01-22 12:00:00,2,2,是,0.0,0.0,0.0,99.84,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,通道冻值,2026-01-25 13:00:00,2026-01-26 08:00:00,20,20,是,94.0,94.0,94.0,99.5,单通道长期不变而同级其他缸在变化,按冻值处理 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-01-29 00:00:00,2026-01-29 01:00:00,2,2,是,0.0,0.0,0.0,104.09,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-02-02 01:00:00,2026-02-02 03:00:00,3,2,是,0.0,0.0,0.0,95.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-02 12:00:00,2026-02-02 14:00:00,3,2,是,0.0,0.0,0.0,106.19,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2026-02-03 01:00:00,2026-02-03 03:00:00,3,2,是,0.0,0.0,0.0,94.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2026-02-05 14:00:00,2026-02-05 15:00:00,2,2,是,0.0,0.0,0.0,104.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,通道骤降,2026-02-13 07:00:00,2026-02-13 08:00:00,2,2,是,100.41,103.87,102.14,111.25,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 4号机,56,YSJ_14,二级2#缸排气温度,二级,2#,通道骤降,2026-02-13 07:00:00,2026-02-13 07:00:00,1,1,否,97.5,97.5,97.5,107.45,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,通道骤降,2026-02-13 07:00:00,2026-02-13 08:00:00,2,2,是,94.8,98.54,96.67,106.03,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-14 15:00:00,2026-02-14 17:00:00,3,2,是,0.0,0.0,0.0,112.41,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2026-02-16 22:00:00,2026-02-16 22:00:00,1,1,是,0.0,0.0,0.0,94.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2026-02-19 04:00:00,2026-02-19 05:00:00,2,2,是,0.0,0.0,0.0,100.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-19 12:00:00,2026-02-19 14:00:00,3,2,是,0.0,0.0,0.0,110.32,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,通道冻值,2026-02-27 13:00:00,2026-02-28 01:00:00,13,13,是,100.97,101.0,101.0,97.72,单通道长期不变而同级其他缸在变化,按冻值处理 4号机,56,YSJ_10,一级2#缸排气温度,一级,2#,通道冻值,2026-02-27 15:00:00,2026-02-28 06:00:00,16,16,是,100.0,100.0,100.0,97.78,单通道长期不变而同级其他缸在变化,按冻值处理 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-02-28 03:00:00,2026-02-28 04:00:00,2,2,是,0.0,0.0,0.0,97.07,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-28 11:00:00,2026-02-28 12:00:00,2,2,是,0.0,0.0,0.0,103.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-03-01 17:00:00,2026-03-01 18:00:00,2,2,是,0.0,0.0,0.0,97.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-03-02 08:00:00,2026-03-02 11:00:00,4,2,是,0.0,0.0,0.0,103.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,通道冻值,2026-03-02 17:00:00,2026-03-03 08:00:00,16,16,是,102.0,102.08,102.0,98.78,单通道长期不变而同级其他缸在变化,按冻值处理 4号机,56,YSJ_14,二级2#缸排气温度,二级,2#,停机/通道异常,2026-03-02 17:00:00,2026-03-02 18:00:00,2,2,是,0.0,0.0,0.0,101.4,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-03-02 18:00:00,2026-03-02 19:00:00,2,2,是,0.0,0.0,0.0,104.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-04-06 21:00:00,2026-04-06 22:00:00,2,2,是,0.0,0.0,0.0,112.58,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-04-07 12:00:00,2026-04-07 14:00:00,3,2,是,0.0,0.0,0.0,115.2,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-04-23 04:00:00,2026-04-23 05:00:00,2,2,是,0.0,0.0,0.0,102.15,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2026-04-30 22:00:00,2026-04-30 22:00:00,1,1,是,0.0,0.0,0.0,110.31,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-05-30 08:00:00,2026-05-30 15:00:00,8,3,是,0.0,0.0,0.0,118.61,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,通道坏道,2026-05-30 15:00:00,2026-05-30 15:00:00,1,1,是,-0.0,-0.0,-0.0,119.6,单通道长期接近环境温度,按坏道处理 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2026-06-07 10:00:00,2026-06-07 11:00:00,2,2,是,0.0,0.0,0.0,111.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-06-08 00:00:00,2026-06-08 01:00:00,2,2,是,0.0,0.0,0.0,112.45,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-06-09 12:00:00,2026-06-09 14:00:00,3,2,是,0.0,0.0,0.0,123.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2026-06-13 18:00:00,2026-06-13 19:00:00,2,2,是,0.0,0.0,0.0,114.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-01-22 05:00:00,2025-01-22 07:00:00,3,2,是,0.0,0.0,0.0,88.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-02-13 10:00:00,2025-02-13 11:00:00,2,2,是,98.65,102.51,100.58,111.79,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-02-13 10:00:00,2025-02-13 11:00:00,2,2,是,99.89,103.78,101.84,113.16,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-02-13 10:00:00,2025-02-13 11:00:00,2,2,是,99.26,103.13,101.19,112.44,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-03-04 22:00:00,2025-03-04 22:00:00,1,1,是,0.0,0.0,0.0,107.19,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-03-11 08:00:00,2025-03-11 10:00:00,3,2,是,0.0,0.0,0.0,108.58,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-03-13 04:00:00,2025-03-13 05:00:00,2,2,是,0.0,0.0,0.0,92.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-03-14 04:00:00,2025-03-14 05:00:00,2,2,是,0.0,0.0,0.0,92.02,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-03-14 07:00:00,2025-03-14 08:00:00,2,2,是,0.0,0.0,0.0,95.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-03-16 01:00:00,2025-03-16 03:00:00,3,2,是,0.0,0.0,0.0,93.27,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-03-16 01:00:00,2025-03-16 03:00:00,3,2,是,0.0,0.0,0.0,90.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-03-16 18:00:00,2025-03-16 19:00:00,2,2,是,0.0,0.0,0.0,96.63,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-03-17 00:00:00,2025-03-17 01:00:00,2,2,是,0.0,0.0,0.0,89.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-03-19 04:00:00,2025-03-19 05:00:00,2,2,是,0.0,0.0,0.0,91.31,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-03-29 11:00:00,2025-03-29 12:00:00,2,2,是,0.0,0.0,0.0,109.83,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-03-31 03:00:00,2025-03-31 04:00:00,2,2,是,0.0,0.0,0.0,90.71,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-04-01 22:00:00,2025-04-01 22:00:00,1,1,是,0.0,0.0,0.0,116.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-04-03 07:00:00,2025-04-03 08:00:00,2,2,是,0.0,0.0,0.0,95.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-04-05 11:00:00,2025-04-05 12:00:00,2,2,是,0.0,0.0,0.0,100.21,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-04-08 00:00:00,2025-04-08 01:00:00,2,2,是,0.0,0.0,0.0,113.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-04-10 10:00:00,2025-04-10 11:00:00,2,2,是,0.0,0.0,0.0,99.93,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-04-14 01:00:00,2025-04-14 03:00:00,3,2,是,0.0,0.0,0.0,96.93,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-04-14 14:00:00,2025-04-14 15:00:00,2,2,是,0.0,0.0,0.0,104.38,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2025-04-17 15:00:00,2025-04-17 15:00:00,1,1,否,9.46,9.46,9.46,110.7,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2025-04-17 15:00:00,2025-04-17 15:00:00,1,1,否,9.46,9.46,9.46,110.64,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2025-04-17 15:00:00,2025-04-17 15:00:00,1,1,否,9.48,9.48,9.48,110.76,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-04-17 15:00:00,2025-04-17 15:00:00,1,1,否,11.38,11.38,11.38,133.71,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-04-17 15:00:00,2025-04-17 15:00:00,1,1,否,11.49,11.49,11.49,135.02,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-04-17 15:00:00,2025-04-17 15:00:00,1,1,否,11.42,11.42,11.42,134.09,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-04-17 22:00:00,2025-04-17 22:00:00,1,1,是,0.0,0.0,0.0,104.43,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2025-04-18 17:00:00,2025-04-18 17:00:00,1,1,否,103.08,103.08,103.08,111.14,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-05-22 01:00:00,2025-05-22 03:00:00,3,2,是,0.0,0.0,0.0,121.23,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-05-24 10:00:00,2025-05-24 11:00:00,2,2,是,0.0,0.0,0.0,106.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-05-25 14:00:00,2025-05-25 15:00:00,2,2,是,0.0,0.0,0.0,102.63,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-05-27 12:00:00,2025-05-27 14:00:00,3,2,是,0.0,0.0,0.0,108.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-05-27 15:00:00,2025-05-27 17:00:00,3,2,是,0.0,0.0,0.0,121.87,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-05-27 19:00:00,2025-05-27 21:00:00,3,2,是,0.0,0.0,0.0,103.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-05-28 19:00:00,2025-05-28 21:00:00,3,2,是,0.0,0.0,0.0,105.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-05-28 21:00:00,2025-05-28 22:00:00,2,2,是,0.0,0.0,0.0,117.45,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-05-29 01:00:00,2025-05-29 03:00:00,3,2,是,0.0,0.0,0.0,101.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-05-30 07:00:00,2025-05-30 14:00:00,8,3,是,0.0,99.72,0.0,120.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-05-30 11:00:00,2025-05-30 14:00:00,4,2,是,0.0,0.0,0.0,105.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-05-30 14:00:00,2025-05-30 14:00:00,1,1,否,97.96,97.96,97.96,122.06,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-05-30 14:00:00,2025-05-30 14:00:00,1,1,否,98.75,98.75,98.75,122.45,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-05-31 05:00:00,2025-05-31 07:00:00,3,2,是,0.0,0.0,0.0,100.84,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-06-12 08:00:00,2025-06-12 10:00:00,3,2,是,0.0,0.0,0.0,112.54,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-07-02 01:00:00,2025-07-02 03:00:00,3,2,是,0.0,0.0,0.0,106.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-07-05 05:00:00,2025-07-05 07:00:00,3,2,是,0.0,0.0,0.0,110.23,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-07-05 17:00:00,2025-07-05 18:00:00,2,2,是,0.0,0.0,0.0,128.85,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-07-06 07:00:00,2025-07-06 08:00:00,2,2,是,0.0,0.0,0.0,123.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-07-10 03:00:00,2025-07-10 04:00:00,2,2,是,0.0,0.0,0.0,125.38,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2025-07-10 16:00:00,2025-07-10 16:00:00,1,1,否,-0.0,-0.0,-0.0,112.43,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2025-07-10 16:00:00,2025-07-10 16:00:00,1,1,否,-0.0,-0.0,-0.0,113.94,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2025-07-10 16:00:00,2025-07-10 16:00:00,1,1,否,-0.0,-0.0,-0.0,114.11,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-07-10 16:00:00,2025-07-10 16:00:00,1,1,否,-0.0,-0.0,-0.0,130.83,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-07-10 16:00:00,2025-07-10 16:00:00,1,1,否,-0.0,-0.0,-0.0,132.58,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-07-10 16:00:00,2025-07-10 16:00:00,1,1,否,-0.0,-0.0,-0.0,131.15,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-07-11 19:00:00,2025-07-11 21:00:00,3,2,是,0.0,0.0,0.0,127.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-08-25 21:00:00,2025-08-25 21:00:00,1,1,是,0.0,0.0,0.0,123.23,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-08-26 12:00:00,2025-08-26 14:00:00,3,2,是,0.0,0.0,0.0,109.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-08-26 21:00:00,2025-08-26 22:00:00,2,2,是,0.0,0.0,0.0,108.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-08-29 11:00:00,2025-08-29 12:00:00,2,2,是,0.0,0.0,0.0,121.04,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-08-30 12:00:00,2025-08-30 14:00:00,3,2,是,0.0,0.0,0.0,107.76,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-09-12 03:00:00,2025-09-12 04:00:00,2,2,是,0.0,0.0,0.0,118.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-09-17 01:00:00,2025-09-17 03:00:00,3,2,是,0.0,0.0,0.0,104.69,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-09-17 11:00:00,2025-09-17 12:00:00,2,2,是,0.0,0.0,0.0,116.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-09-17 21:00:00,2025-09-17 22:00:00,2,2,是,0.0,0.0,0.0,113.95,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-10-27 01:00:00,2025-10-27 03:00:00,3,2,是,0.0,0.0,0.0,106.4,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-01 10:00:00,2025-11-01 11:00:00,2,2,是,0.0,0.0,0.0,102.62,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-15 15:00:00,2025-11-15 16:00:00,2,2,是,-0.0,-0.0,-0.0,103.69,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-15 15:00:00,2025-11-15 16:00:00,2,2,是,-0.0,-0.0,-0.0,101.51,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-15 15:00:00,2025-11-15 16:00:00,2,2,是,-0.0,-0.0,-0.0,105.11,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-15 15:00:00,2025-11-15 16:00:00,2,2,是,-0.0,-0.0,-0.0,117.55,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-11-15 15:00:00,2025-11-15 16:00:00,2,2,是,-0.0,-0.0,-0.0,118.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-11-15 15:00:00,2025-11-15 16:00:00,2,2,是,-0.0,-0.0,-0.0,118.74,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-16 07:00:00,2025-11-16 08:00:00,2,2,是,0.0,0.0,0.0,108.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-16 10:00:00,2025-11-16 11:00:00,2,2,是,0.0,0.0,0.0,102.63,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-16 18:00:00,2025-11-16 19:00:00,2,2,是,0.0,0.0,0.0,101.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2025-11-17 10:00:00,2025-11-17 15:00:00,6,2,是,8.05,8.13,8.09,96.72,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2025-11-17 10:00:00,2025-11-17 15:00:00,6,2,是,7.91,7.97,7.94,94.7,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2025-11-17 10:00:00,2025-11-17 15:00:00,6,2,是,8.22,8.29,8.25,98.44,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-11-17 10:00:00,2025-11-17 15:00:00,6,2,是,8.73,8.9,8.82,105.79,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-11-17 10:00:00,2025-11-17 15:00:00,6,2,是,8.78,8.93,8.85,106.16,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-11-17 10:00:00,2025-11-17 15:00:00,6,2,是,8.84,8.99,8.92,106.97,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-11-19 01:00:00,2025-11-19 03:00:00,3,2,是,0.0,0.0,0.0,105.33,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-25 11:00:00,2025-11-25 12:00:00,2,2,是,0.0,0.0,0.0,108.97,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-30 07:00:00,2025-11-30 08:00:00,2,2,是,0.0,0.0,0.0,95.5,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-30 08:00:00,2025-11-30 10:00:00,3,2,是,0.0,0.0,0.0,105.51,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-12-08 00:00:00,2025-12-08 01:00:00,2,2,是,0.0,0.0,0.0,116.35,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-12-08 01:00:00,2025-12-08 03:00:00,3,2,是,0.0,0.0,0.0,92.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-12-11 15:00:00,2025-12-11 17:00:00,3,2,是,0.0,0.0,0.0,91.76,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-12-12 12:00:00,2025-12-12 14:00:00,3,2,是,0.0,0.0,0.0,95.29,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-12-22 12:00:00,2025-12-22 14:00:00,3,2,是,0.0,0.0,0.0,104.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-12-22 15:00:00,2025-12-22 17:00:00,3,2,是,0.0,0.0,0.0,105.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-12-23 21:00:00,2025-12-23 22:00:00,2,2,是,0.0,0.0,0.0,90.53,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-01-14 21:00:00,2026-01-14 22:00:00,2,2,是,0.0,0.0,0.0,106.8,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-01-15 05:00:00,2026-01-15 07:00:00,3,2,是,0.0,0.0,0.0,105.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-16 17:00:00,2026-01-16 18:00:00,2,2,是,0.0,0.0,0.0,95.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-01-22 11:00:00,2026-01-22 12:00:00,2,2,是,0.0,0.0,0.0,91.46,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-23 14:00:00,2026-01-23 15:00:00,2,2,是,0.0,0.0,0.0,92.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-31 07:00:00,2026-01-31 08:00:00,2,2,是,0.0,0.0,0.0,90.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-02-03 01:00:00,2026-02-03 03:00:00,3,2,是,0.0,0.0,0.0,93.52,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-02-03 10:00:00,2026-02-03 15:00:00,6,4,是,0.0,0.0,0.0,105.02,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-02-06 00:00:00,2026-02-06 01:00:00,2,2,是,0.0,0.0,0.0,104.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-02-07 08:00:00,2026-02-07 10:00:00,3,2,是,0.0,0.0,0.0,102.99,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-02-08 04:00:00,2026-02-08 05:00:00,2,2,是,0.0,0.0,0.0,99.38,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-02-10 12:00:00,2026-02-10 14:00:00,3,2,是,0.0,0.0,0.0,110.69,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-10 21:00:00,2026-02-10 22:00:00,2,2,是,0.0,0.0,0.0,104.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-12 10:00:00,2026-02-12 11:00:00,2,2,是,0.0,0.0,0.0,107.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-02-18 04:00:00,2026-02-18 05:00:00,2,2,是,0.0,0.0,0.0,102.93,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-02-19 07:00:00,2026-02-19 08:00:00,2,2,是,0.0,0.0,0.0,89.54,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-02-24 14:00:00,2026-02-24 15:00:00,2,2,是,0.0,0.0,0.0,92.92,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-02-27 17:00:00,2026-02-27 18:00:00,2,2,是,0.0,0.0,0.0,91.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-02-28 01:00:00,2026-02-28 03:00:00,3,2,是,0.0,0.0,0.0,90.76,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-03-03 21:00:00,2026-03-03 22:00:00,2,2,是,0.0,0.0,0.0,92.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-03-06 18:00:00,2026-03-06 19:00:00,2,2,是,0.0,0.0,0.0,105.04,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-03-06 19:00:00,2026-03-06 21:00:00,3,2,是,0.0,0.0,0.0,89.47,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-03-09 01:00:00,2026-03-09 03:00:00,3,2,是,0.0,0.0,0.0,95.75,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-03-09 14:00:00,2026-03-09 15:00:00,2,2,是,0.0,0.0,0.0,110.83,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-03-10 21:00:00,2026-03-10 22:00:00,2,2,是,0.0,0.0,0.0,108.74,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-03-13 11:00:00,2026-03-13 12:00:00,2,2,是,0.0,0.0,0.0,118.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2026-03-25 10:00:00,2026-03-25 10:00:00,1,1,否,118.07,118.07,118.07,126.08,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2026-03-31 18:00:00,2026-03-31 19:00:00,2,2,是,7.55,7.64,7.6,91.42,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2026-03-31 18:00:00,2026-03-31 19:00:00,2,2,是,8.18,8.27,8.22,98.85,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2026-03-31 18:00:00,2026-03-31 19:00:00,2,2,是,7.55,7.64,7.6,91.35,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2026-03-31 18:00:00,2026-03-31 19:00:00,2,2,是,8.95,9.06,9.01,107.73,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2026-03-31 18:00:00,2026-03-31 19:00:00,2,2,是,9.08,9.2,9.14,109.36,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2026-03-31 18:00:00,2026-03-31 19:00:00,2,2,是,9.02,9.13,9.07,108.54,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-04-14 17:00:00,2026-04-14 18:00:00,2,2,是,0.0,0.0,0.0,98.84,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-04-14 19:00:00,2026-04-14 21:00:00,3,2,是,0.0,0.0,0.0,96.61,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-04-15 18:00:00,2026-04-15 19:00:00,2,2,是,0.0,0.0,0.0,114.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-04-17 01:00:00,2026-04-17 03:00:00,3,2,是,0.0,0.0,0.0,93.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-05-02 08:00:00,2026-05-02 10:00:00,3,2,是,0.0,0.0,0.0,99.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-05-05 07:00:00,2026-05-05 08:00:00,2,2,是,0.0,0.0,0.0,113.25,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-05-05 19:00:00,2026-05-05 21:00:00,3,2,是,0.0,0.0,0.0,100.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-05-05 21:00:00,2026-05-05 22:00:00,2,2,是,0.0,0.0,0.0,99.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-05-07 11:00:00,2026-05-07 12:00:00,2,2,是,0.0,0.0,0.0,103.84,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-05-09 01:00:00,2026-05-09 03:00:00,3,2,是,0.0,0.0,0.0,110.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-06-05 03:00:00,2026-06-05 04:00:00,2,2,是,0.0,0.0,0.0,117.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2026-06-30 19:00:00,2026-06-30 20:00:00,2,2,是,109.24,118.31,113.77,128.75,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2026-06-30 19:00:00,2026-06-30 20:00:00,2,2,是,110.81,119.7,115.26,130.23,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2026-06-30 19:00:00,2026-06-30 20:00:00,2,2,是,118.87,119.04,118.95,129.3,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-01-18 00:00:00,2025-01-18 01:00:00,2,2,是,0.0,0.0,0.0,88.19,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-02-15 08:00:00,2025-02-15 09:00:00,2,2,是,96.31,99.51,97.91,106.96,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-02-15 08:00:00,2025-02-15 09:00:00,2,2,是,96.91,100.11,98.51,107.63,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-02-15 08:00:00,2025-02-15 09:00:00,2,2,是,95.74,99.03,97.39,106.65,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-02-24 22:00:00,2025-02-24 22:00:00,1,1,是,0.0,0.0,0.0,100.62,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-02-27 05:00:00,2025-02-27 07:00:00,3,2,是,0.0,0.0,0.0,100.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-02-27 22:00:00,2025-02-27 22:00:00,1,1,是,0.0,0.0,0.0,91.85,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-03-01 11:00:00,2025-03-01 12:00:00,2,2,是,0.0,0.0,0.0,98.41,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-03-02 05:00:00,2025-03-02 07:00:00,3,2,是,0.0,0.0,0.0,106.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-03-02 18:00:00,2025-03-02 19:00:00,2,2,是,0.0,0.0,0.0,102.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-03-02 19:00:00,2025-03-02 21:00:00,3,2,是,0.0,0.0,0.0,90.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-05-31 14:00:00,2025-05-31 15:00:00,2,2,是,0.0,0.0,0.0,106.35,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-06-01 10:00:00,2025-06-01 11:00:00,2,2,是,0.0,0.0,0.0,116.03,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-06-02 04:00:00,2025-06-02 04:00:00,1,1,否,90.67,90.67,90.67,112.7,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-06-02 04:00:00,2025-06-02 04:00:00,1,1,否,90.88,90.88,90.88,113.23,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-06-02 04:00:00,2025-06-02 04:00:00,1,1,否,89.69,89.69,89.69,112.14,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-06-17 03:00:00,2025-06-17 04:00:00,2,2,是,0.0,0.0,0.0,113.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-06-18 11:00:00,2025-06-18 12:00:00,2,2,是,0.0,0.0,0.0,107.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-06-21 00:00:00,2025-06-21 01:00:00,2,2,是,0.0,0.0,0.0,104.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2025-06-22 09:00:00,2025-06-22 09:00:00,1,1,否,18.45,18.45,18.45,110.48,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2025-06-22 09:00:00,2025-06-22 09:00:00,1,1,否,18.51,18.51,18.51,110.84,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2025-06-22 09:00:00,2025-06-22 09:00:00,1,1,否,18.4,18.4,18.4,110.15,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-06-22 09:00:00,2025-06-22 09:00:00,1,1,否,20.58,20.58,20.58,123.39,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-06-22 09:00:00,2025-06-22 09:00:00,1,1,否,20.68,20.68,20.68,123.91,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-06-22 09:00:00,2025-06-22 09:00:00,1,1,否,20.52,20.52,20.52,123.01,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-06-27 00:00:00,2025-06-27 01:00:00,2,2,是,0.0,0.0,0.0,104.29,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-07-18 00:00:00,2025-07-18 01:00:00,2,2,是,0.0,0.0,0.0,109.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2025-08-01 09:00:00,2025-08-01 09:00:00,1,1,否,18.75,18.75,18.75,113.39,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2025-08-01 09:00:00,2025-08-01 09:00:00,1,1,否,18.77,18.77,18.77,113.54,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2025-08-01 09:00:00,2025-08-01 09:00:00,1,1,否,18.62,18.62,18.62,112.66,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-08-01 09:00:00,2025-08-01 09:00:00,1,1,否,21.01,21.01,21.01,126.82,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-08-01 09:00:00,2025-08-01 09:00:00,1,1,否,21.06,21.06,21.06,127.24,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-08-01 09:00:00,2025-08-01 09:00:00,1,1,否,20.94,20.94,20.94,126.48,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-08-03 19:00:00,2025-08-03 21:00:00,3,2,是,0.0,0.0,0.0,128.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-08-13 03:00:00,2025-08-13 04:00:00,2,2,是,0.0,0.0,0.0,109.74,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-08-23 22:00:00,2025-08-23 22:00:00,1,1,是,0.0,0.0,0.0,108.65,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-08-31 19:00:00,2025-08-31 21:00:00,3,2,是,0.0,0.0,0.0,122.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-09-03 21:00:00,2025-09-03 22:00:00,2,2,是,0.0,0.0,0.0,104.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-09-08 15:00:00,2025-09-08 17:00:00,3,2,是,0.0,0.0,0.0,123.27,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-09-09 03:00:00,2025-09-09 04:00:00,2,2,是,0.0,0.0,0.0,116.53,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-09-19 04:00:00,2025-09-19 05:00:00,2,2,是,0.0,0.0,0.0,109.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-09-21 21:00:00,2025-09-21 22:00:00,2,2,是,0.0,0.0,0.0,108.25,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-09-23 11:00:00,2025-09-23 11:00:00,1,1,否,90.13,90.13,90.13,112.55,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-09-23 11:00:00,2025-09-23 11:00:00,1,1,否,90.18,90.18,90.18,112.94,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-09-23 11:00:00,2025-09-23 11:00:00,1,1,否,89.6,89.6,89.6,112.39,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-10-07 17:00:00,2025-10-07 18:00:00,2,2,是,0.0,0.0,0.0,115.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-10-11 19:00:00,2025-10-11 21:00:00,3,2,是,0.0,0.0,0.0,101.63,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-10-14 15:00:00,2025-10-14 17:00:00,3,2,是,0.0,0.0,0.0,102.21,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-10-16 05:00:00,2025-10-16 07:00:00,3,2,是,0.0,0.0,0.0,113.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-10-20 12:00:00,2025-10-20 14:00:00,3,2,是,0.0,0.0,0.0,98.04,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-10-23 12:00:00,2025-10-23 14:00:00,3,2,是,0.0,0.0,0.0,100.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-10-29 17:00:00,2025-10-29 18:00:00,2,2,是,0.0,0.0,0.0,119.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-10-30 08:00:00,2025-10-30 10:00:00,3,2,是,0.0,0.0,0.0,102.66,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-10-30 08:00:00,2025-10-30 10:00:00,3,2,是,0.0,0.0,0.0,104.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-10-31 04:00:00,2025-10-31 05:00:00,2,2,是,0.0,0.0,0.0,100.37,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-03 18:00:00,2025-11-03 19:00:00,2,2,是,0.0,0.0,0.0,98.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-11-06 04:00:00,2025-11-06 05:00:00,2,2,是,0.0,0.0,0.0,110.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-07 08:00:00,2025-11-07 10:00:00,3,2,是,0.0,0.0,0.0,110.32,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-08 22:00:00,2025-11-08 22:00:00,1,1,是,0.0,0.0,0.0,95.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-10 09:00:00,2025-11-10 15:00:00,7,2,是,-0.0,-0.0,-0.0,97.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-10 09:00:00,2025-11-10 15:00:00,7,2,是,-0.0,-0.0,-0.0,97.23,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-10 09:00:00,2025-11-10 15:00:00,7,2,是,-0.0,-0.0,-0.0,98.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-10 09:00:00,2025-11-10 15:00:00,7,2,是,-0.0,-0.0,-0.0,109.15,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-11-10 09:00:00,2025-11-10 15:00:00,7,2,是,-0.0,-0.0,-0.0,109.15,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-11-10 09:00:00,2025-11-10 15:00:00,7,2,是,-0.0,-0.0,-0.0,108.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-11 17:00:00,2025-11-11 17:00:00,1,1,是,-0.0,-0.0,-0.0,106.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-11 17:00:00,2025-11-11 17:00:00,1,1,是,-0.0,-0.0,-0.0,105.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-11 17:00:00,2025-11-11 17:00:00,1,1,是,-0.0,-0.0,-0.0,107.41,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-11 17:00:00,2025-11-11 17:00:00,1,1,是,-0.0,-0.0,-0.0,124.23,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-11-11 17:00:00,2025-11-11 17:00:00,1,1,是,-0.0,-0.0,-0.0,124.34,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-11-11 17:00:00,2025-11-11 17:00:00,1,1,是,-0.0,-0.0,-0.0,130.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-12 11:00:00,2025-11-12 11:00:00,1,1,是,-0.0,-0.0,-0.0,104.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-12 11:00:00,2025-11-12 11:00:00,1,1,是,-0.0,-0.0,-0.0,103.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-12 11:00:00,2025-11-12 11:00:00,1,1,是,-0.0,-0.0,-0.0,105.46,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-12 11:00:00,2025-11-12 11:00:00,1,1,是,-0.0,-0.0,-0.0,118.97,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-11-12 11:00:00,2025-11-12 11:00:00,1,1,是,-0.0,-0.0,-0.0,118.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-11-12 11:00:00,2025-11-12 11:00:00,1,1,是,-0.0,-0.0,-0.0,124.12,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,97.29,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,96.27,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,97.71,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,110.94,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,111.06,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,110.51,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-22 22:00:00,2025-11-22 22:00:00,1,1,是,0.0,0.0,0.0,97.99,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-11-22 22:00:00,2025-11-22 22:00:00,1,1,否,84.24,84.24,84.24,110.51,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-11-22 22:00:00,2025-11-22 22:00:00,1,1,否,84.32,84.32,84.32,110.64,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-11-22 22:00:00,2025-11-22 22:00:00,1,1,否,83.53,83.53,83.53,109.73,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-12-08 21:00:00,2025-12-08 22:00:00,2,2,是,0.0,0.0,0.0,93.61,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-12-08 22:00:00,2025-12-08 22:00:00,1,1,是,0.0,0.0,0.0,109.58,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-12-12 00:00:00,2025-12-12 01:00:00,2,2,是,0.0,0.0,0.0,101.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-12-13 19:00:00,2025-12-13 21:00:00,3,2,是,0.0,0.0,0.0,92.99,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-12-14 03:00:00,2025-12-14 04:00:00,2,2,是,0.0,0.0,0.0,103.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-12-16 15:00:00,2025-12-16 17:00:00,3,2,是,0.0,0.0,0.0,114.47,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-12-18 04:00:00,2025-12-18 05:00:00,2,2,是,0.0,0.0,0.0,107.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-12-26 09:00:00,2025-12-26 09:00:00,1,1,否,101.74,101.74,101.74,110.61,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-12-26 09:00:00,2025-12-26 09:00:00,1,1,否,102.1,102.1,102.1,111.04,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-12-26 09:00:00,2025-12-26 09:00:00,1,1,否,101.12,101.12,101.12,110.12,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-12-28 14:00:00,2025-12-28 15:00:00,2,2,是,0.0,0.0,0.0,96.18,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-12-29 11:00:00,2025-12-29 12:00:00,2,2,是,0.0,0.0,0.0,107.19,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2026-01-03 09:00:00,2026-01-03 09:00:00,1,1,否,-0.0,-0.0,-0.0,90.05,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2026-01-03 09:00:00,2026-01-03 09:00:00,1,1,否,-0.0,-0.0,-0.0,89.44,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2026-01-03 09:00:00,2026-01-03 09:00:00,1,1,否,-0.0,-0.0,-0.0,91.97,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2026-01-03 09:00:00,2026-01-03 09:00:00,1,1,否,-0.0,-0.0,-0.0,103.4,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2026-01-03 09:00:00,2026-01-03 09:00:00,1,1,否,-0.0,-0.0,-0.0,103.52,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2026-01-03 09:00:00,2026-01-03 09:00:00,1,1,否,-0.0,-0.0,-0.0,102.56,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-09 05:00:00,2026-01-09 14:00:00,10,4,是,0.0,67.52,33.38,93.87,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2026-01-09 13:00:00,2026-01-09 14:00:00,2,2,是,66.17,67.12,66.65,94.22,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2026-01-09 13:00:00,2026-01-09 14:00:00,2,2,是,68.05,68.65,68.35,92.26,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2026-01-09 13:00:00,2026-01-09 14:00:00,2,2,是,84.8,85.19,84.99,115.19,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2026-01-09 13:00:00,2026-01-09 14:00:00,2,2,是,86.32,86.39,86.36,115.4,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2026-01-09 13:00:00,2026-01-09 14:00:00,2,2,是,85.23,85.31,85.27,114.88,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-10 01:00:00,2026-01-10 03:00:00,3,2,是,0.0,0.0,0.0,92.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-01-10 04:00:00,2026-01-10 05:00:00,2,2,是,0.0,0.0,0.0,108.34,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-01-16 21:00:00,2026-01-16 22:00:00,2,2,是,0.0,0.0,0.0,93.1,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2026-01-17 09:00:00,2026-01-17 09:00:00,1,1,否,98.69,98.69,98.69,106.89,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2026-01-17 09:00:00,2026-01-17 09:00:00,1,1,否,98.51,98.51,98.51,106.55,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2026-01-17 09:00:00,2026-01-17 09:00:00,1,1,否,97.9,97.9,97.9,106.15,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-01-18 08:00:00,2026-01-18 10:00:00,3,2,是,0.0,0.0,0.0,89.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-01-18 08:00:00,2026-01-18 10:00:00,3,2,是,0.0,0.0,0.0,92.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-01-18 18:00:00,2026-01-18 19:00:00,2,2,是,0.0,0.0,0.0,102.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-07 18:00:00,2026-02-07 19:00:00,2,2,是,0.0,0.0,0.0,109.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-02-08 17:00:00,2026-02-08 18:00:00,2,2,是,0.0,0.0,0.0,92.07,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-02-11 05:00:00,2026-02-11 07:00:00,3,2,是,0.0,0.0,0.0,88.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-02-15 03:00:00,2026-02-15 04:00:00,2,2,是,0.0,0.0,0.0,103.92,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-16 03:00:00,2026-02-16 04:00:00,2,2,是,0.0,0.0,0.0,108.12,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-02-16 15:00:00,2026-02-16 17:00:00,3,2,是,0.0,0.0,0.0,90.03,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-17 19:00:00,2026-02-17 21:00:00,3,2,是,0.0,0.0,0.0,114.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-02-17 22:00:00,2026-02-17 22:00:00,1,1,是,0.0,0.0,0.0,94.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,通道坏道,2026-02-18 21:00:00,2026-02-18 21:00:00,1,1,是,-0.0,-0.0,-0.0,96.13,单通道长期接近环境温度,按坏道处理 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-23 22:00:00,2026-02-23 22:00:00,1,1,是,0.0,0.0,0.0,98.59,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-02-25 08:00:00,2026-02-25 10:00:00,3,2,是,0.0,0.0,0.0,102.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-04-12 15:00:00,2026-04-12 17:00:00,3,2,是,0.0,0.0,0.0,100.35,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-04-13 01:00:00,2026-04-13 03:00:00,3,2,是,0.0,0.0,0.0,97.19,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-04-20 07:00:00,2026-04-20 08:00:00,2,2,是,0.0,0.0,0.0,94.83,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-05-12 00:00:00,2026-05-12 01:00:00,2,2,是,0.0,0.0,0.0,98.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-05-15 07:00:00,2026-05-15 08:00:00,2,2,是,0.0,0.0,0.0,115.88,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-05-15 14:00:00,2026-05-15 15:00:00,2,2,是,0.0,0.0,0.0,122.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-05-17 14:00:00,2026-05-17 21:00:00,8,4,是,0.0,0.0,0.0,116.24,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-05-17 15:00:00,2026-05-17 17:00:00,3,2,是,0.0,0.0,0.0,101.38,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-05-20 12:00:00,2026-05-20 14:00:00,3,2,是,0.0,0.0,0.0,124.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-05-20 14:00:00,2026-05-20 15:00:00,2,2,是,0.0,0.0,0.0,107.61,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-05-21 10:00:00,2026-05-21 11:00:00,2,2,是,0.0,0.0,0.0,104.95,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-05-21 19:00:00,2026-05-21 21:00:00,3,2,是,0.0,0.0,0.0,120.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-05-23 00:00:00,2026-05-23 01:00:00,2,2,是,0.0,0.0,0.0,118.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-05-24 11:00:00,2026-05-24 12:00:00,2,2,是,0.0,0.0,0.0,102.24,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-05-25 04:00:00,2026-05-25 05:00:00,2,2,是,0.0,0.0,0.0,117.61,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-05-25 12:00:00,2026-05-25 14:00:00,3,2,是,0.0,0.0,0.0,102.75,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-05-25 19:00:00,2026-05-25 21:00:00,3,2,是,0.0,0.0,0.0,116.8,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-05-27 18:00:00,2026-05-27 19:00:00,2,2,是,0.0,0.0,0.0,122.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,通道坏道,2026-05-30 07:00:00,2026-05-30 07:00:00,1,1,是,-0.0,-0.0,-0.0,96.22,单通道长期接近环境温度,按坏道处理 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,通道坏道,2026-05-30 07:00:00,2026-05-30 07:00:00,1,1,是,-0.0,-0.0,-0.0,97.61,单通道长期接近环境温度,按坏道处理 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,通道坏道,2026-05-30 07:00:00,2026-05-30 07:00:00,1,1,是,-0.0,-0.0,-0.0,96.43,单通道长期接近环境温度,按坏道处理 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道坏道,2026-05-30 07:00:00,2026-05-30 09:00:00,3,2,是,-0.0,-0.0,-0.0,110.26,单通道长期接近环境温度,按坏道处理 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道坏道,2026-05-30 07:00:00,2026-05-30 09:00:00,3,2,是,-0.0,-0.0,-0.0,110.14,单通道长期接近环境温度,按坏道处理 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道坏道,2026-05-30 07:00:00,2026-05-30 09:00:00,3,2,是,-0.0,-0.0,-0.0,109.71,单通道长期接近环境温度,按坏道处理 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-06-22 11:00:00,2026-06-22 17:00:00,7,4,是,0.0,0.0,0.0,123.71,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-06-22 21:00:00,2026-06-22 22:00:00,2,2,是,0.0,0.0,0.0,120.17,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-06-23 00:00:00,2026-06-23 01:00:00,2,2,是,0.0,0.0,0.0,104.24,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-06-23 08:00:00,2026-06-23 10:00:00,3,2,是,0.0,0.0,0.0,107.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-06-25 08:00:00,2026-06-25 10:00:00,3,2,是,0.0,0.0,0.0,122.03,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-01-01 14:00:00,2025-01-01 15:00:00,2,2,是,0.0,0.0,0.0,86.11,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-01-01 18:00:00,2025-01-01 19:00:00,2,2,是,0.0,0.0,0.0,89.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-01-02 10:00:00,2025-01-02 11:00:00,2,2,是,0.0,0.0,0.0,82.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-01-05 10:00:00,2025-01-05 10:00:00,1,1,否,81.07,81.07,81.07,90.19,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-01-05 10:00:00,2025-01-05 10:00:00,1,1,否,80.31,80.31,80.31,89.58,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-01-06 01:00:00,2025-01-06 03:00:00,3,2,是,0.0,0.0,0.0,82.07,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-01-06 01:00:00,2025-01-06 05:00:00,5,4,是,0.0,0.0,0.0,81.53,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-01-06 12:00:00,2025-01-06 14:00:00,3,2,是,0.0,0.0,0.0,82.54,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-01-09 18:00:00,2025-01-09 19:00:00,2,2,是,0.0,0.0,0.0,84.45,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-01-24 10:00:00,2025-01-24 11:00:00,2,2,是,0.0,0.0,0.0,81.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-01-25 11:00:00,2025-01-25 12:00:00,2,2,是,0.0,0.0,0.0,82.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-01-26 05:00:00,2025-01-26 07:00:00,3,2,是,0.0,0.0,0.0,82.28,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-01-26 15:00:00,2025-01-26 17:00:00,3,2,是,0.0,0.0,0.0,83.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-01-27 21:00:00,2025-01-27 22:00:00,2,2,是,0.0,0.0,0.0,84.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-01-28 21:00:00,2025-01-28 22:00:00,2,2,是,0.0,0.0,0.0,82.33,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-01-29 05:00:00,2025-01-29 07:00:00,3,2,是,0.0,0.0,0.0,83.51,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-01-29 14:00:00,2025-01-29 14:00:00,1,1,是,0.0,0.0,0.0,58.29,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-01-30 11:00:00,2025-01-30 12:00:00,2,2,是,0.0,0.0,0.0,82.17,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-02-01 04:00:00,2025-02-01 05:00:00,2,2,是,0.0,0.0,0.0,80.76,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-02-01 12:00:00,2025-02-01 14:00:00,3,2,是,0.0,0.0,0.0,82.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-02-01 18:00:00,2025-02-01 19:00:00,2,2,是,0.0,0.0,0.0,81.88,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-02-03 08:00:00,2025-02-03 10:00:00,3,2,是,0.0,0.0,0.0,82.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-02-03 11:00:00,2025-02-03 12:00:00,2,2,是,0.0,0.0,0.0,83.37,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-02-05 04:00:00,2025-02-05 05:00:00,2,2,是,0.0,0.0,0.0,81.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-02-07 00:00:00,2025-02-07 01:00:00,2,2,是,0.0,0.0,0.0,81.29,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-02-07 12:00:00,2025-02-07 14:00:00,3,2,是,0.0,0.0,0.0,79.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-02-10 17:00:00,2025-02-10 18:00:00,2,2,是,0.0,0.0,0.0,86.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-02-11 04:00:00,2025-02-11 05:00:00,2,2,是,0.0,0.0,0.0,82.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_17,一级4列缸排气温度,一级,4列,通道坏道,2025-02-11 17:00:00,2025-02-11 17:00:00,1,1,是,0.0,0.0,0.0,82.26,单通道长期接近环境温度,按坏道处理 7号机,47,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-02-12 14:00:00,2025-02-12 15:00:00,2,2,是,0.0,0.0,0.0,58.35,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-02-12 17:00:00,2025-02-12 18:00:00,2,2,是,0.0,0.0,0.0,82.1,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-02-24 07:00:00,2025-02-24 08:00:00,2,2,是,0.0,0.0,0.0,81.33,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-02-28 07:00:00,2025-02-28 08:00:00,2,2,是,0.0,0.0,0.0,81.65,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-03-22 03:00:00,2025-03-22 04:00:00,2,2,是,0.0,0.0,0.0,83.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-03-22 19:00:00,2025-03-22 21:00:00,3,2,是,0.0,0.0,0.0,94.18,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-03-23 05:00:00,2025-03-23 07:00:00,3,2,是,0.0,0.0,0.0,87.09,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-03-24 19:00:00,2025-03-24 21:00:00,3,2,是,0.0,0.0,0.0,88.21,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-03-26 10:00:00,2025-03-26 11:00:00,2,2,是,0.0,0.0,0.0,89.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-03-30 03:00:00,2025-03-30 04:00:00,2,2,是,0.0,0.0,0.0,81.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-03-30 07:00:00,2025-03-30 08:00:00,2,2,是,0.0,0.0,0.0,83.1,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,47,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-03-31 05:00:00,2025-03-31 07:00:00,3,2,是,0.0,0.0,0.0,83.03,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-04-11 07:00:00,2025-04-11 08:00:00,2,2,是,0.0,0.0,0.0,93.4,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-04-14 01:00:00,2025-04-14 03:00:00,3,2,是,0.0,0.0,0.0,95.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-04-15 01:00:00,2025-04-15 03:00:00,3,2,是,0.0,0.0,0.0,94.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-04-15 15:00:00,2025-04-15 17:00:00,3,2,是,0.0,0.0,0.0,98.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-16 01:00:00,2025-04-16 03:00:00,3,2,是,0.0,0.0,0.0,95.19,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-04-16 01:00:00,2025-04-16 03:00:00,3,2,是,0.0,0.0,0.0,94.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-16 03:00:00,2025-04-16 04:00:00,2,2,是,0.0,0.0,0.0,94.38,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-16 14:00:00,2025-04-16 15:00:00,2,2,是,0.0,0.0,0.0,100.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-04-24 19:00:00,2025-04-24 21:00:00,3,2,是,0.0,0.0,0.0,93.17,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-26 10:00:00,2025-04-26 11:00:00,2,2,是,0.0,0.0,0.0,102.66,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-04-26 19:00:00,2025-04-26 21:00:00,3,2,是,0.0,0.0,0.0,99.85,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-26 22:00:00,2025-04-26 22:00:00,1,1,是,0.0,0.0,0.0,97.46,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-04-27 07:00:00,2025-04-27 08:00:00,2,2,是,0.0,0.0,0.0,66.83,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-30 01:00:00,2025-04-30 03:00:00,3,2,是,0.0,0.0,0.0,97.47,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-04-30 04:00:00,2025-04-30 05:00:00,2,2,是,0.0,0.0,0.0,95.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-05-06 07:00:00,2025-05-06 08:00:00,2,2,是,0.0,0.0,0.0,95.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-05-14 07:00:00,2025-05-14 18:00:00,12,6,是,0.0,0.0,0.0,101.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-05-16 06:00:00,2025-05-16 08:00:00,3,3,是,88.92,92.67,90.38,100.03,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-05-16 06:00:00,2025-05-16 08:00:00,3,3,是,88.76,92.54,90.24,99.88,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,通道骤降,2025-05-16 07:00:00,2025-05-16 07:00:00,1,1,否,62.77,62.77,62.77,70.99,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-05-16 14:00:00,2025-05-16 15:00:00,2,2,是,0.0,0.0,0.0,102.58,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,通道坏道,2025-05-17 17:00:00,2025-05-17 17:00:00,1,1,是,0.0,0.0,0.0,100.15,单通道长期接近环境温度,按坏道处理 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-05-18 00:00:00,2025-05-18 01:00:00,2,2,是,0.0,0.0,0.0,90.89,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-05-20 05:00:00,2025-05-20 07:00:00,3,2,是,0.0,0.0,0.0,101.07,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-05-25 03:00:00,2025-05-25 04:00:00,2,2,是,0.0,0.0,0.0,88.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-05-29 00:00:00,2025-05-29 01:00:00,2,2,是,0.0,0.0,0.0,62.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-05-29 18:00:00,2025-05-29 19:00:00,2,2,是,0.0,0.0,0.0,103.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-06-01 10:00:00,2025-06-01 11:00:00,2,2,是,0.0,0.0,0.0,99.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-06-01 12:00:00,2025-06-01 14:00:00,3,2,是,0.0,0.0,0.0,67.12,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-06-03 03:00:00,2025-06-03 04:00:00,2,2,是,0.0,0.0,0.0,94.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-06-03 08:00:00,2025-06-03 10:00:00,3,2,是,0.0,0.0,0.0,100.58,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-06-04 00:00:00,2025-06-04 01:00:00,2,2,是,0.0,0.0,0.0,99.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-06-04 03:00:00,2025-06-04 04:00:00,2,2,是,0.0,0.0,0.0,68.47,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-06-04 04:00:00,2025-06-04 05:00:00,2,2,是,0.0,0.0,0.0,94.92,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-06-05 08:00:00,2025-06-05 08:00:00,1,1,否,98.32,98.32,98.32,107.48,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-06-05 08:00:00,2025-06-05 08:00:00,1,1,否,98.64,98.64,98.64,107.78,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-06-05 12:00:00,2025-06-05 14:00:00,3,2,是,0.0,0.0,0.0,106.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-06-06 08:00:00,2025-06-06 15:00:00,8,3,是,0.0,99.05,0.0,110.03,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-06-06 08:00:00,2025-06-06 08:00:00,1,1,否,99.4,99.4,99.4,110.07,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,通道骤降,2025-06-06 08:00:00,2025-06-06 08:00:00,1,1,否,71.95,71.95,71.95,81.09,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-06-06 18:00:00,2025-06-06 19:00:00,2,2,是,0.0,0.0,0.0,78.62,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-06-08 04:00:00,2025-06-08 05:00:00,2,2,是,0.0,0.0,0.0,108.58,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-06-08 15:00:00,2025-06-08 17:00:00,3,2,是,0.0,0.0,0.0,109.24,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-06-10 04:00:00,2025-06-10 05:00:00,2,2,是,0.0,0.0,0.0,106.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-06-11 22:00:00,2025-06-11 22:00:00,1,1,是,0.0,0.0,0.0,78.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-06-12 05:00:00,2025-06-12 07:00:00,3,2,是,0.0,0.0,0.0,110.83,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,通道坏道,2025-06-12 15:00:00,2025-06-12 15:00:00,1,1,是,0.0,0.0,0.0,109.87,单通道长期接近环境温度,按坏道处理 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-07-20 21:00:00,2025-07-20 22:00:00,2,2,是,0.0,0.0,0.0,69.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-07-22 07:00:00,2025-07-22 08:00:00,2,2,是,0.0,0.0,0.0,100.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-07-22 22:00:00,2025-07-22 22:00:00,1,1,是,0.0,0.0,0.0,101.18,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-07-24 22:00:00,2025-07-24 22:00:00,1,1,是,0.0,0.0,0.0,105.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-07-25 18:00:00,2025-07-25 19:00:00,2,2,是,0.0,0.0,0.0,107.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-07-27 03:00:00,2025-07-27 04:00:00,2,2,是,0.0,0.0,0.0,104.53,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-07-27 03:00:00,2025-07-27 04:00:00,2,2,是,0.0,0.0,0.0,73.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-07-27 10:00:00,2025-07-27 11:00:00,2,2,是,0.0,0.0,0.0,106.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-07-30 03:00:00,2025-07-30 04:00:00,2,2,是,0.0,0.0,0.0,101.27,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-07-30 18:00:00,2025-07-30 19:00:00,2,2,是,0.0,0.0,0.0,107.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-08-01 00:00:00,2025-08-01 01:00:00,2,2,是,0.0,0.0,0.0,77.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-08-07 17:00:00,2025-08-07 18:00:00,2,2,是,0.0,0.0,0.0,78.53,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-08-08 12:00:00,2025-08-08 14:00:00,3,2,是,0.0,0.0,0.0,107.18,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-08-27 11:00:00,2025-08-27 12:00:00,2,2,是,0.0,0.0,0.0,74.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-08-28 00:00:00,2025-08-28 01:00:00,2,2,是,0.0,0.0,0.0,105.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-08-28 05:00:00,2025-08-28 07:00:00,3,2,是,0.0,0.0,0.0,98.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-08-28 19:00:00,2025-08-28 21:00:00,3,2,是,0.0,0.0,0.0,101.18,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-09-10 07:00:00,2025-09-10 08:00:00,2,2,是,0.0,0.0,0.0,102.75,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-09-20 01:00:00,2025-09-20 03:00:00,3,2,是,0.0,0.0,0.0,88.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-09-20 11:00:00,2025-09-20 12:00:00,2,2,是,0.0,0.0,0.0,94.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-09-21 05:00:00,2025-09-21 07:00:00,3,2,是,0.0,0.0,0.0,100.65,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-09-22 11:00:00,2025-09-22 12:00:00,2,2,是,0.0,0.0,0.0,90.55,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-10-03 21:00:00,2025-10-03 22:00:00,2,2,是,0.0,0.0,0.0,91.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-10-04 19:00:00,2025-10-04 21:00:00,3,2,是,0.0,0.0,0.0,91.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-10-05 15:00:00,2025-10-05 17:00:00,3,2,是,0.0,0.0,0.0,101.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-10-06 01:00:00,2025-10-06 03:00:00,3,2,是,0.0,0.0,0.0,92.09,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-10-06 12:00:00,2025-10-06 12:00:00,1,1,是,0.0,0.0,0.0,100.31,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-11-16 05:00:00,2025-11-16 07:00:00,3,2,是,0.0,0.0,0.0,95.11,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-11-19 14:00:00,2025-11-19 14:00:00,1,1,是,0.0,0.0,0.0,58.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-11-19 21:00:00,2025-11-19 22:00:00,2,2,是,0.0,0.0,0.0,80.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-11-20 05:00:00,2025-11-20 07:00:00,3,2,是,0.0,0.0,0.0,93.73,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-11-23 14:00:00,2025-11-23 15:00:00,2,2,是,0.0,0.0,0.0,59.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-11-27 10:00:00,2025-11-27 11:00:00,2,2,是,0.0,0.0,0.0,82.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-11-29 00:00:00,2025-11-29 01:00:00,2,2,是,0.0,0.0,0.0,80.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-11-29 21:00:00,2025-11-29 22:00:00,2,2,是,0.0,0.0,0.0,92.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-11-30 19:00:00,2025-11-30 21:00:00,3,2,是,0.0,0.0,0.0,82.94,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-12-01 07:00:00,2025-12-01 08:00:00,2,2,是,0.0,0.0,0.0,79.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-12-02 10:00:00,2025-12-02 11:00:00,2,2,是,0.0,0.0,0.0,83.04,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-12-05 00:00:00,2025-12-05 01:00:00,2,2,是,0.0,0.0,0.0,82.31,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-12-06 04:00:00,2025-12-06 05:00:00,2,2,是,0.0,0.0,0.0,90.75,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-12-07 04:00:00,2025-12-07 05:00:00,2,2,是,0.0,0.0,0.0,94.17,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-01-12 03:00:00,2026-01-12 04:00:00,2,2,是,0.0,0.0,0.0,87.03,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-01-20 00:00:00,2026-01-20 01:00:00,2,2,是,0.0,0.0,0.0,82.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-02-14 07:00:00,2026-02-14 08:00:00,2,2,是,0.0,0.0,0.0,90.1,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-03-13 12:00:00,2026-03-13 14:00:00,3,2,是,0.0,0.0,0.0,92.97,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-13 22:00:00,2026-03-13 22:00:00,1,1,是,0.0,0.0,0.0,93.71,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-03-14 05:00:00,2026-03-14 07:00:00,3,2,是,0.0,0.0,0.0,98.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-03-20 07:00:00,2026-03-20 08:00:00,2,2,是,0.0,0.0,0.0,99.63,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-21 10:00:00,2026-03-21 11:00:00,2,2,是,0.0,0.0,0.0,94.66,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-22 04:00:00,2026-03-22 05:00:00,2,2,是,0.0,0.0,0.0,93.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-03-22 10:00:00,2026-03-22 11:00:00,2,2,是,0.0,0.0,0.0,93.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-03-23 11:00:00,2026-03-23 12:00:00,2,2,是,0.0,0.0,0.0,93.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-27 18:00:00,2026-03-28 03:00:00,10,4,是,0.0,0.0,0.0,94.85,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-03-27 22:00:00,2026-03-27 22:00:00,1,1,是,0.0,0.0,0.0,93.33,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-03-29 12:00:00,2026-03-29 14:00:00,3,2,是,0.0,0.0,0.0,94.18,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-04-01 10:00:00,2026-04-01 11:00:00,2,2,是,0.0,0.0,0.0,101.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-04-02 00:00:00,2026-04-02 03:00:00,4,2,是,0.0,0.0,0.0,98.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-04-02 07:00:00,2026-04-02 08:00:00,2,2,是,0.0,0.0,0.0,98.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-04-02 11:00:00,2026-04-02 12:00:00,2,2,是,0.0,0.0,0.0,96.4,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-05-08 07:00:00,2026-05-08 08:00:00,2,2,是,0.0,0.0,0.0,95.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-05-11 18:00:00,2026-05-11 19:00:00,2,2,是,0.0,0.0,0.0,102.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-05-12 04:00:00,2026-05-12 05:00:00,2,2,是,0.0,0.0,0.0,98.33,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-05-12 22:00:00,2026-05-12 22:00:00,1,1,是,0.0,0.0,0.0,99.52,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-05-16 10:00:00,2026-05-16 11:00:00,2,2,是,0.0,0.0,0.0,96.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-05-17 07:00:00,2026-05-17 08:00:00,2,2,是,0.0,0.0,0.0,62.11,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-05-18 22:00:00,2026-05-18 22:00:00,1,1,是,0.0,0.0,0.0,98.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-05-19 08:00:00,2026-05-19 10:00:00,3,2,是,0.0,0.0,0.0,100.27,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-05-20 04:00:00,2026-05-20 05:00:00,2,2,是,0.0,0.0,0.0,96.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-06-02 05:00:00,2026-06-02 07:00:00,3,2,是,0.0,0.0,0.0,98.25,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-06-03 17:00:00,2026-06-03 18:00:00,2,2,是,0.0,0.0,0.0,108.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-04 10:00:00,2026-06-04 11:00:00,2,2,是,0.0,0.0,0.0,101.45,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-06-05 08:00:00,2026-06-05 10:00:00,3,2,是,0.0,0.0,0.0,103.63,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-06-05 10:00:00,2026-06-05 11:00:00,2,2,是,0.0,0.0,0.0,101.65,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-06-05 14:00:00,2026-06-05 15:00:00,2,2,是,0.0,0.0,0.0,103.43,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-28 17:00:00,2026-06-28 18:00:00,2,2,是,0.0,0.0,0.0,102.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-29 18:00:00,2026-06-29 19:00:00,2,2,是,0.0,0.0,0.0,100.32,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-06-30 12:00:00,2026-06-30 14:00:00,3,2,是,0.0,0.0,0.0,71.43,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-30 17:00:00,2026-06-30 18:00:00,2,2,是,0.0,0.0,0.0,102.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-07-13 15:00:00,2026-07-13 17:00:00,3,2,是,0.0,0.0,0.0,106.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-07-13 19:00:00,2026-07-13 21:00:00,3,2,是,0.0,0.0,0.0,104.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-07-15 12:00:00,2026-07-15 14:00:00,3,2,是,0.0,0.0,0.0,70.99,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-07-16 03:00:00,2026-07-16 04:00:00,2,2,是,0.0,0.0,0.0,103.15,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-07-17 03:00:00,2026-07-17 04:00:00,2,2,是,0.0,0.0,0.0,66.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-07-19 00:00:00,2026-07-19 01:00:00,2,2,是,0.0,0.0,0.0,71.17,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-07-20 07:00:00,2026-07-20 08:00:00,2,2,是,0.0,0.0,0.0,104.76,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-07-20 07:00:00,2026-07-20 08:00:00,2,2,是,0.0,0.0,0.0,103.88,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 7号机,50,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-07-27 21:00:00,2026-07-27 22:00:00,2,2,是,0.0,0.0,0.0,102.97,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-01-01 03:00:00,2025-01-01 03:00:00,1,1,是,0.0,0.0,0.0,89.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-01-02 04:00:00,2025-01-02 05:00:00,2,2,是,0.0,0.0,0.0,82.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-01-02 17:00:00,2025-01-02 18:00:00,2,2,是,0.0,0.0,0.0,83.11,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,通道坏道,2025-01-09 07:00:00,2025-01-09 07:00:00,1,1,是,0.0,0.0,0.0,80.46,单通道长期接近环境温度,按坏道处理 8号机,48,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-01-18 12:00:00,2025-01-18 14:00:00,3,2,是,0.0,0.0,0.0,84.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-01-24 10:00:00,2025-01-24 11:00:00,2,2,是,0.0,0.0,0.0,78.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-01-27 03:00:00,2025-01-27 04:00:00,2,2,是,0.0,0.0,0.0,78.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-01-27 19:00:00,2025-01-27 21:00:00,3,2,是,0.0,0.0,0.0,76.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-01-28 18:00:00,2025-01-28 19:00:00,2,2,是,0.0,0.0,0.0,80.8,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-01-29 19:00:00,2025-01-29 21:00:00,3,2,是,0.0,0.0,0.0,81.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-01-29 22:00:00,2025-01-29 22:00:00,1,1,是,0.0,0.0,0.0,82.55,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-02-02 12:00:00,2025-02-02 14:00:00,3,2,是,0.0,0.0,0.0,81.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-02-08 03:00:00,2025-02-08 04:00:00,2,2,是,0.0,0.0,0.0,78.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-02-10 11:00:00,2025-02-10 12:00:00,2,2,是,0.0,0.0,0.0,81.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-02-10 17:00:00,2025-02-10 18:00:00,2,2,是,0.0,0.0,0.0,82.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-02-11 22:00:00,2025-02-11 22:00:00,1,1,是,0.0,0.0,0.0,79.32,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-02-13 00:00:00,2025-02-13 01:00:00,2,2,是,0.0,0.0,0.0,79.51,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-02-13 08:00:00,2025-02-13 10:00:00,3,2,是,0.0,0.0,0.0,79.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-02-13 11:00:00,2025-02-13 12:00:00,2,2,是,0.0,0.0,0.0,81.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-03-13 14:00:00,2025-03-13 15:00:00,2,2,是,0.0,0.0,0.0,87.11,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-03-14 03:00:00,2025-03-14 04:00:00,2,2,是,0.0,0.0,0.0,84.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-03-15 22:00:00,2025-03-15 22:00:00,1,1,是,0.0,0.0,0.0,82.47,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-03-23 18:00:00,2025-03-23 19:00:00,2,2,是,0.0,0.0,0.0,95.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-03-24 01:00:00,2025-03-24 03:00:00,3,2,是,0.0,0.0,0.0,89.04,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,48,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-03-26 12:00:00,2025-03-26 14:00:00,3,2,是,0.0,0.0,0.0,101.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-01 18:00:00,2025-04-01 19:00:00,2,2,是,0.0,0.0,0.0,95.47,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-02 11:00:00,2025-04-02 12:00:00,2,2,是,0.0,0.0,0.0,94.69,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-02 14:00:00,2025-04-02 15:00:00,2,2,是,0.0,0.0,0.0,91.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-06 07:00:00,2025-04-06 08:00:00,2,2,是,0.0,0.0,0.0,85.73,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-04-06 10:00:00,2025-04-06 10:00:00,1,1,是,0.0,0.0,0.0,63.94,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-07 07:00:00,2025-04-07 08:00:00,2,2,是,0.0,0.0,0.0,85.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-21 04:00:00,2025-04-21 05:00:00,2,2,是,0.0,0.0,0.0,96.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-21 08:00:00,2025-04-21 10:00:00,3,2,是,0.0,0.0,0.0,93.38,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,通道坏道,2025-04-22 14:00:00,2025-04-22 14:00:00,1,1,是,0.0,0.0,0.0,97.82,单通道长期接近环境温度,按坏道处理 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-23 05:00:00,2025-04-23 07:00:00,3,2,是,0.0,0.0,0.0,88.15,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-04-25 07:00:00,2025-04-25 08:00:00,2,2,是,80.99,83.67,82.33,91.72,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-04-25 07:00:00,2025-04-25 08:00:00,2,2,是,80.2,82.87,81.54,90.79,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 8号机,31,YSJ_21,三级1列缸排气温度,三级,1列,通道骤降,2025-04-25 07:00:00,2025-04-25 07:00:00,1,1,否,57.32,57.32,57.32,65.84,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-28 07:00:00,2025-04-28 08:00:00,2,2,是,0.0,0.0,0.0,95.18,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-04-30 05:00:00,2025-04-30 07:00:00,3,2,是,0.0,0.0,0.0,89.35,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-05-01 03:00:00,2025-05-01 04:00:00,2,2,是,0.0,0.0,0.0,94.87,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-05-01 22:00:00,2025-05-01 22:00:00,1,1,是,0.0,0.0,0.0,98.95,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-05-02 21:00:00,2025-05-02 22:00:00,2,2,是,0.0,0.0,0.0,92.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-05-05 00:00:00,2025-05-05 01:00:00,2,2,是,0.0,0.0,0.0,96.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-05-26 07:00:00,2025-05-26 12:00:00,6,4,是,0.0,0.0,0.0,98.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-05-28 03:00:00,2025-05-28 04:00:00,2,2,是,0.0,0.0,0.0,96.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-05-28 03:00:00,2025-05-28 04:00:00,2,2,是,0.0,0.0,0.0,90.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-06-19 10:00:00,2025-06-19 11:00:00,2,2,是,0.0,0.0,0.0,99.87,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-06-20 00:00:00,2025-06-20 01:00:00,2,2,是,0.0,0.0,0.0,95.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-06-20 03:00:00,2025-06-20 04:00:00,2,2,是,0.0,0.0,0.0,100.46,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-06-21 15:00:00,2025-06-21 17:00:00,3,2,是,0.0,0.0,0.0,106.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-06-23 11:00:00,2025-06-23 12:00:00,2,2,是,0.0,0.0,0.0,105.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-06-23 22:00:00,2025-06-23 22:00:00,1,1,是,0.0,0.0,0.0,98.33,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-06-24 22:00:00,2025-06-24 22:00:00,1,1,是,0.0,0.0,0.0,99.61,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-06-25 08:00:00,2025-06-25 10:00:00,3,2,是,0.0,0.0,0.0,102.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-06-25 21:00:00,2025-06-25 22:00:00,2,2,是,0.0,0.0,0.0,95.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-06-27 21:00:00,2025-06-27 22:00:00,2,2,是,0.0,0.0,0.0,102.03,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-06-28 00:00:00,2025-06-28 01:00:00,2,2,是,0.0,0.0,0.0,68.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-06-28 07:00:00,2025-06-28 08:00:00,2,2,是,0.0,0.0,0.0,97.41,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-06-28 18:00:00,2025-06-28 19:00:00,2,2,是,0.0,0.0,0.0,103.95,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-06-29 19:00:00,2025-06-29 21:00:00,3,2,是,0.0,0.0,0.0,102.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-06-30 03:00:00,2025-06-30 04:00:00,2,2,是,0.0,0.0,0.0,96.17,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-07-01 01:00:00,2025-07-01 03:00:00,3,2,是,0.0,0.0,0.0,102.29,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,通道坏道,2025-07-02 08:00:00,2025-07-02 08:00:00,1,1,是,0.0,0.0,0.0,101.87,单通道长期接近环境温度,按坏道处理 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-07-08 05:00:00,2025-07-08 07:00:00,3,2,是,0.0,0.0,0.0,98.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-07-08 21:00:00,2025-07-08 22:00:00,2,2,是,0.0,0.0,0.0,104.53,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-07-09 01:00:00,2025-07-09 03:00:00,3,2,是,0.0,0.0,0.0,97.66,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-09-26 03:00:00,2025-09-26 04:00:00,2,2,是,0.0,0.0,0.0,89.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-09-29 08:00:00,2025-09-29 10:00:00,3,2,是,0.0,0.0,0.0,66.85,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-09-30 00:00:00,2025-09-30 01:00:00,2,2,是,0.0,0.0,0.0,98.97,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-09-30 12:00:00,2025-09-30 14:00:00,3,2,是,0.0,0.0,0.0,100.21,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-10-01 08:00:00,2025-10-01 10:00:00,3,2,是,0.0,0.0,0.0,98.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-10-01 10:00:00,2025-10-01 11:00:00,2,2,是,0.0,0.0,0.0,91.08,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-10-01 12:00:00,2025-10-01 14:00:00,3,2,是,0.0,0.0,0.0,99.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-10-23 01:00:00,2025-10-23 03:00:00,3,2,是,0.0,0.0,0.0,83.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-12-16 12:00:00,2025-12-16 14:00:00,3,2,是,0.0,0.0,0.0,91.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-12-20 00:00:00,2025-12-20 01:00:00,2,2,是,0.0,0.0,0.0,90.87,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-12-20 18:00:00,2025-12-20 19:00:00,2,2,是,0.0,0.0,0.0,90.33,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-12-21 04:00:00,2025-12-21 05:00:00,2,2,是,0.0,0.0,0.0,77.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-12-31 19:00:00,2025-12-31 21:00:00,3,2,是,0.0,0.0,0.0,77.65,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-01-11 00:00:00,2026-01-11 01:00:00,2,2,是,0.0,0.0,0.0,77.51,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-01-11 22:00:00,2026-01-11 22:00:00,1,1,是,0.0,0.0,0.0,89.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-03-15 19:00:00,2026-03-15 21:00:00,3,2,是,0.0,0.0,0.0,83.8,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-03-17 01:00:00,2026-03-17 03:00:00,3,2,是,0.0,0.0,0.0,89.84,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-03-17 17:00:00,2026-03-17 18:00:00,2,2,是,0.0,0.0,0.0,87.5,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-03-18 00:00:00,2026-03-18 01:00:00,2,2,是,0.0,0.0,0.0,88.29,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-03-21 04:00:00,2026-03-21 05:00:00,2,2,是,0.0,0.0,0.0,64.59,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-03-21 21:00:00,2026-03-21 22:00:00,2,2,是,0.0,0.0,0.0,87.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-04-25 21:00:00,2026-04-25 22:00:00,2,2,是,0.0,0.0,0.0,93.95,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-04-30 07:00:00,2026-04-30 08:00:00,2,2,是,0.0,0.0,0.0,86.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-05-01 21:00:00,2026-05-01 22:00:00,2,2,是,0.0,0.0,0.0,86.32,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-05-02 14:00:00,2026-05-02 15:00:00,2,2,是,0.0,0.0,0.0,91.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-05-04 17:00:00,2026-05-04 18:00:00,2,2,是,0.0,0.0,0.0,94.94,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-05-06 04:00:00,2026-05-06 05:00:00,2,2,是,0.0,0.0,0.0,89.21,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-05-31 01:00:00,2026-05-31 03:00:00,3,2,是,0.0,0.0,0.0,98.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-05-31 08:00:00,2026-05-31 10:00:00,3,2,是,0.0,0.0,0.0,94.17,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-05-31 18:00:00,2026-05-31 19:00:00,2,2,是,0.0,0.0,0.0,98.39,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-06-01 07:00:00,2026-06-01 08:00:00,2,2,是,0.0,0.0,0.0,99.84,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-06-07 03:00:00,2026-06-07 04:00:00,2,2,是,0.0,0.0,0.0,92.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-07 10:00:00,2026-06-07 11:00:00,2,2,是,0.0,0.0,0.0,98.99,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-07 18:00:00,2026-06-07 19:00:00,2,2,是,0.0,0.0,0.0,98.27,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-06-09 05:00:00,2026-06-09 07:00:00,3,2,是,0.0,0.0,0.0,98.69,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-06-11 03:00:00,2026-06-11 04:00:00,2,2,是,0.0,0.0,0.0,98.81,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-06-13 05:00:00,2026-06-13 07:00:00,3,2,是,0.0,0.0,0.0,100.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-14 07:00:00,2026-06-14 08:00:00,2,2,是,0.0,0.0,0.0,98.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-06-14 15:00:00,2026-06-14 17:00:00,3,2,是,0.0,0.0,0.0,102.41,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-14 17:00:00,2026-06-15 01:00:00,9,4,是,0.0,0.0,0.0,100.07,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-06-16 03:00:00,2026-06-16 04:00:00,2,2,是,0.0,0.0,0.0,67.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-17 04:00:00,2026-06-17 05:00:00,2,2,是,0.0,0.0,0.0,98.88,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-06-17 17:00:00,2026-06-17 18:00:00,2,2,是,0.0,0.0,0.0,101.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-07-20 21:00:00,2026-07-21 10:00:00,14,6,是,0.0,0.0,0.0,105.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-07-22 12:00:00,2026-07-22 14:00:00,3,2,是,0.0,0.0,0.0,104.69,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-07-22 15:00:00,2026-07-22 17:00:00,3,2,是,0.0,0.0,0.0,69.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-07-26 05:00:00,2026-07-26 07:00:00,3,2,是,0.0,0.0,0.0,100.1,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-07-27 00:00:00,2026-07-27 01:00:00,2,2,是,0.0,0.0,0.0,102.45,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-07-28 19:00:00,2026-07-28 21:00:00,3,2,是,0.0,0.0,0.0,100.62,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-07-29 03:00:00,2026-07-29 04:00:00,2,2,是,0.0,0.0,0.0,103.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 8号机,51,YSJ_19,二级3列缸排气温度,二级,3列,通道坏道,2026-07-29 21:00:00,2026-07-29 21:00:00,1,1,是,0.0,0.0,0.0,101.51,单通道长期接近环境温度,按坏道处理 8号机,51,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-07-30 03:00:00,2026-07-30 04:00:00,2,2,是,0.0,0.0,0.0,67.21,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,49,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-01-11 03:00:00,2025-01-11 04:00:00,2,2,是,0.0,0.0,0.0,76.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,49,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-01-13 10:00:00,2025-01-13 11:00:00,2,2,是,0.0,0.0,0.0,77.46,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,49,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-01-13 19:00:00,2025-01-13 21:00:00,3,2,是,0.0,0.0,0.0,79.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,49,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-01-14 17:00:00,2025-01-14 18:00:00,2,2,是,0.0,0.0,0.0,81.73,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,49,YSJ_18,一级6列缸排气温度,一级,6列,通道骤降,2025-03-07 11:00:00,2025-03-07 11:00:00,1,1,否,54.93,54.93,54.93,80.8,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,49,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-03-07 11:00:00,2025-03-07 12:00:00,2,2,是,48.6,59.89,54.25,78.77,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,49,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-03-07 11:00:00,2025-03-07 12:00:00,2,2,是,46.97,58.73,52.85,77.69,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,49,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-03-12 14:00:00,2025-03-12 14:00:00,1,1,否,54.41,54.41,54.41,85.32,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,49,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-03-12 14:00:00,2025-03-12 14:00:00,1,1,否,51.74,51.74,51.74,84.57,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,49,YSJ_21,三级1列缸排气温度,三级,1列,通道骤降,2025-03-12 14:00:00,2025-03-12 14:00:00,1,1,否,52.21,52.21,52.21,60.34,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,49,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-03-13 03:00:00,2025-03-13 04:00:00,2,2,是,0.0,0.0,0.0,79.23,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,49,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-03-14 07:00:00,2025-03-14 08:00:00,2,2,是,0.0,0.0,0.0,78.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,49,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-03-27 05:00:00,2025-03-27 07:00:00,3,2,是,0.0,0.0,0.0,85.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,49,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-03-28 00:00:00,2025-03-28 01:00:00,2,2,是,0.0,0.0,0.0,83.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-10 01:00:00,2025-04-10 03:00:00,3,2,是,0.0,0.0,0.0,84.73,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-04-18 03:00:00,2025-04-18 04:00:00,2,2,是,0.0,0.0,0.0,89.8,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-04-20 22:00:00,2025-04-20 22:00:00,1,1,是,0.0,0.0,0.0,90.81,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-04-22 10:00:00,2025-04-22 11:00:00,2,2,是,0.0,0.0,0.0,70.75,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-04-23 06:00:00,2025-04-23 09:00:00,4,4,是,83.03,91.01,84.16,96.93,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-04-23 06:00:00,2025-04-23 09:00:00,4,4,是,82.03,90.1,83.19,95.99,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,通道骤降,2025-04-23 06:00:00,2025-04-23 08:00:00,3,3,是,62.93,64.3,63.59,74.65,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-05-12 21:00:00,2025-05-12 22:00:00,2,2,是,0.0,0.0,0.0,98.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-05-13 18:00:00,2025-05-13 19:00:00,2,2,是,0.0,0.0,0.0,98.93,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-05-14 10:00:00,2025-05-14 11:00:00,2,2,是,0.0,0.0,0.0,100.09,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-05-15 21:00:00,2025-05-15 22:00:00,2,2,是,0.0,0.0,0.0,98.97,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-05-16 17:00:00,2025-05-16 18:00:00,2,2,是,0.0,0.0,0.0,71.31,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-05-17 08:00:00,2025-05-17 10:00:00,3,2,是,0.0,0.0,0.0,68.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-05-17 19:00:00,2025-05-17 21:00:00,3,2,是,0.0,0.0,0.0,97.09,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-05-19 15:00:00,2025-05-19 17:00:00,3,2,是,0.0,0.0,0.0,104.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-05-22 22:00:00,2025-05-22 22:00:00,1,1,是,0.0,0.0,0.0,96.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-05-26 05:00:00,2025-05-26 07:00:00,3,2,是,0.0,0.0,0.0,97.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-05-27 00:00:00,2025-05-27 01:00:00,2,2,是,0.0,0.0,0.0,97.73,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-05-27 18:00:00,2025-05-27 19:00:00,2,2,是,0.0,0.0,0.0,95.39,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-05-28 15:00:00,2025-05-28 17:00:00,3,2,是,0.0,0.0,0.0,102.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-06-01 14:00:00,2025-06-01 15:00:00,2,2,是,0.0,0.0,0.0,100.39,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-06-03 07:00:00,2025-06-03 08:00:00,2,2,是,0.0,0.0,0.0,90.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-06-07 00:00:00,2025-06-07 01:00:00,2,2,是,0.0,0.0,0.0,101.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-06-07 11:00:00,2025-06-07 12:00:00,2,2,是,0.0,0.0,0.0,73.37,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-06-07 21:00:00,2025-06-07 22:00:00,2,2,是,0.0,0.0,0.0,103.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-06-09 01:00:00,2025-06-09 03:00:00,3,2,是,0.0,0.0,0.0,100.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-06-09 18:00:00,2025-06-09 19:00:00,2,2,是,0.0,0.0,0.0,101.21,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-06-11 01:00:00,2025-06-11 03:00:00,3,2,是,0.0,0.0,0.0,103.43,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-06-13 03:00:00,2025-06-13 04:00:00,2,2,是,0.0,0.0,0.0,104.39,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-06-13 14:00:00,2025-06-13 15:00:00,2,2,是,0.0,0.0,0.0,76.25,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-06-17 21:00:00,2025-06-17 22:00:00,2,2,是,0.0,0.0,0.0,104.81,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-06-18 07:00:00,2025-06-18 08:00:00,2,2,是,0.0,0.0,0.0,97.2,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-07-02 19:00:00,2025-07-02 21:00:00,3,2,是,0.0,0.0,0.0,106.38,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-07-18 14:00:00,2025-07-18 15:00:00,2,2,是,0.0,0.0,0.0,76.63,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-07-21 07:00:00,2025-07-21 14:00:00,8,4,是,0.0,0.0,0.0,105.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-07-21 08:00:00,2025-07-21 10:00:00,3,2,是,0.0,0.0,0.0,106.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-07-21 12:00:00,2025-07-21 14:00:00,3,2,是,0.0,0.0,0.0,99.4,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-07-22 05:00:00,2025-07-22 07:00:00,3,2,是,0.0,0.0,0.0,105.95,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-07-23 17:00:00,2025-07-23 18:00:00,2,2,是,0.0,0.0,0.0,106.28,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-07-24 04:00:00,2025-07-24 05:00:00,2,2,是,0.0,0.0,0.0,96.19,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-07-24 15:00:00,2025-07-24 17:00:00,3,2,是,0.0,0.0,0.0,102.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-08-09 18:00:00,2025-08-09 19:00:00,2,2,是,0.0,0.0,0.0,99.45,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-08-10 00:00:00,2025-08-10 01:00:00,2,2,是,0.0,0.0,0.0,104.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-08-16 22:00:00,2025-08-16 22:00:00,1,1,是,0.0,0.0,0.0,105.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-08-17 14:00:00,2025-08-17 15:00:00,2,2,是,0.0,0.0,0.0,110.4,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-08-18 01:00:00,2025-08-18 03:00:00,3,2,是,0.0,0.0,0.0,96.58,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-08-18 19:00:00,2025-08-18 21:00:00,3,2,是,0.0,0.0,0.0,107.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-08-20 07:00:00,2025-08-20 14:00:00,8,4,是,0.0,0.0,0.0,100.43,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-08-21 10:00:00,2025-08-21 11:00:00,2,2,是,0.0,0.0,0.0,72.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-08-24 01:00:00,2025-08-24 03:00:00,3,2,是,0.0,0.0,0.0,67.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-08-30 07:00:00,2025-08-30 08:00:00,2,2,是,0.0,0.0,0.0,102.65,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-08-30 12:00:00,2025-08-30 14:00:00,3,2,是,0.0,0.0,0.0,105.55,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-08-31 19:00:00,2025-08-31 21:00:00,3,2,是,0.0,0.0,0.0,96.15,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-08-31 19:00:00,2025-08-31 21:00:00,3,2,是,0.0,0.0,0.0,69.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-09-01 04:00:00,2025-09-01 05:00:00,2,2,是,0.0,0.0,0.0,102.2,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-09-01 04:00:00,2025-09-01 05:00:00,2,2,是,0.0,0.0,0.0,92.66,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-09-06 04:00:00,2025-09-06 05:00:00,2,2,是,0.0,0.0,0.0,65.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-09-07 07:00:00,2025-09-07 08:00:00,2,2,是,0.0,0.0,0.0,90.89,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-09-23 21:00:00,2025-09-23 22:00:00,2,2,是,0.0,0.0,0.0,66.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-10-02 14:00:00,2025-10-02 15:00:00,2,2,是,0.0,0.0,0.0,101.81,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-10-03 14:00:00,2025-10-03 15:00:00,2,2,是,0.0,0.0,0.0,100.62,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-10-04 00:00:00,2025-10-04 01:00:00,2,2,是,0.0,0.0,0.0,89.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-10-06 05:00:00,2025-10-06 07:00:00,3,2,是,0.0,0.0,0.0,99.24,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-10-07 10:00:00,2025-10-07 11:00:00,2,2,是,0.0,0.0,0.0,69.12,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-10-10 11:00:00,2025-10-10 12:00:00,2,2,是,0.0,0.0,0.0,85.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-10-11 07:00:00,2025-10-11 08:00:00,2,2,是,0.0,0.0,0.0,100.09,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-10-12 15:00:00,2025-10-12 17:00:00,3,2,是,0.0,0.0,0.0,65.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-10-18 00:00:00,2025-10-18 01:00:00,2,2,是,0.0,0.0,0.0,98.25,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-10-18 05:00:00,2025-10-18 07:00:00,3,2,是,0.0,0.0,0.0,84.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-10-19 10:00:00,2025-10-19 11:00:00,2,2,是,0.0,0.0,0.0,98.94,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-10-20 07:00:00,2025-10-20 08:00:00,2,2,是,0.0,0.0,0.0,97.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-10-20 15:00:00,2025-10-20 17:00:00,3,2,是,0.0,0.0,0.0,94.89,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-10-21 08:00:00,2025-10-21 10:00:00,3,2,是,0.0,0.0,0.0,97.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-10-21 19:00:00,2025-10-21 21:00:00,3,2,是,0.0,0.0,0.0,96.74,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-11-02 03:00:00,2025-11-02 04:00:00,2,2,是,0.0,0.0,0.0,94.12,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-11-06 17:00:00,2025-11-06 18:00:00,2,2,是,0.0,0.0,0.0,82.02,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,通道坏道,2025-11-08 00:00:00,2025-11-08 00:00:00,1,1,是,0.0,0.0,0.0,59.96,单通道长期接近环境温度,按坏道处理 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-11-12 09:00:00,2025-11-12 09:00:00,1,1,否,79.35,79.35,79.35,87.67,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-11-12 09:00:00,2025-11-12 09:00:00,1,1,否,78.43,78.43,78.43,86.72,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,通道骤降,2025-11-12 09:00:00,2025-11-12 09:00:00,1,1,否,67.46,67.46,67.46,76.32,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,通道骤降,2025-11-14 16:00:00,2025-11-14 16:00:00,1,1,否,-0.0,-0.0,-0.0,98.74,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,通道骤降,2025-11-14 16:00:00,2025-11-14 16:00:00,1,1,否,-0.0,-0.0,-0.0,97.73,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,通道骤降,2025-11-14 16:00:00,2025-11-14 16:00:00,1,1,否,-0.0,-0.0,-0.0,96.49,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-11-14 16:00:00,2025-11-14 16:00:00,1,1,否,-0.0,-0.0,-0.0,86.19,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-11-14 16:00:00,2025-11-14 16:00:00,1,1,否,-0.0,-0.0,-0.0,85.29,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,通道骤降,2025-11-14 16:00:00,2025-11-14 16:00:00,1,1,否,-0.0,-0.0,-0.0,69.98,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-01-22 10:00:00,2026-01-22 11:00:00,2,2,是,0.0,0.0,0.0,82.83,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-01-24 14:00:00,2026-01-24 15:00:00,2,2,是,0.0,0.0,0.0,92.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-01-25 22:00:00,2026-01-25 22:00:00,1,1,是,0.0,0.0,0.0,89.45,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-01-29 05:00:00,2026-01-29 07:00:00,3,2,是,0.0,0.0,0.0,65.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-01-31 08:00:00,2026-01-31 10:00:00,3,2,是,0.0,0.0,0.0,91.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-02-01 05:00:00,2026-02-01 07:00:00,3,2,是,0.0,0.0,0.0,64.83,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-02-01 15:00:00,2026-02-01 17:00:00,3,2,是,0.0,0.0,0.0,91.85,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-02-04 01:00:00,2026-02-04 03:00:00,3,2,是,0.0,0.0,0.0,61.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-02-04 04:00:00,2026-02-04 05:00:00,2,2,是,0.0,0.0,0.0,89.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-02-04 19:00:00,2026-02-04 22:00:00,4,2,是,0.0,0.0,0.0,93.41,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-02-06 14:00:00,2026-02-06 15:00:00,2,2,是,0.0,0.0,0.0,92.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-03 19:00:00,2026-03-03 21:00:00,3,2,是,0.0,0.0,0.0,94.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-06 00:00:00,2026-03-06 01:00:00,2,2,是,0.0,0.0,0.0,92.74,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-03-06 05:00:00,2026-03-06 07:00:00,3,2,是,0.0,0.0,0.0,62.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-03-07 07:00:00,2026-03-07 08:00:00,2,2,是,0.0,0.0,0.0,90.25,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-03-07 15:00:00,2026-03-07 17:00:00,3,2,是,0.0,0.0,0.0,61.04,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-03-08 05:00:00,2026-03-08 07:00:00,3,2,是,0.0,0.0,0.0,61.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-09 18:00:00,2026-03-09 19:00:00,2,2,是,0.0,0.0,0.0,93.35,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-03-10 00:00:00,2026-03-10 01:00:00,2,2,是,0.0,0.0,0.0,90.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-13 07:00:00,2026-03-13 08:00:00,2,2,是,0.0,0.0,0.0,93.2,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-03-23 03:00:00,2026-03-23 04:00:00,2,2,是,0.0,0.0,0.0,91.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-03-23 04:00:00,2026-03-23 05:00:00,2,2,是,0.0,0.0,0.0,90.5,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-03-23 18:00:00,2026-03-23 19:00:00,2,2,是,0.0,0.0,0.0,92.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-03-25 15:00:00,2026-03-25 17:00:00,3,2,是,0.0,0.0,0.0,94.09,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-03-25 15:00:00,2026-03-25 17:00:00,3,2,是,0.0,0.0,0.0,93.43,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-04-03 15:00:00,2026-04-03 17:00:00,3,2,是,0.0,0.0,0.0,95.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-04-03 21:00:00,2026-04-03 22:00:00,2,2,是,0.0,0.0,0.0,90.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-04-04 04:00:00,2026-04-04 05:00:00,2,2,是,0.0,0.0,0.0,92.37,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-04-05 22:00:00,2026-04-05 22:00:00,1,1,是,0.0,0.0,0.0,90.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-04-10 12:00:00,2026-04-10 14:00:00,3,2,是,0.0,0.0,0.0,95.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-04-12 08:00:00,2026-04-12 10:00:00,3,2,是,0.0,0.0,0.0,94.59,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-04-12 17:00:00,2026-04-12 18:00:00,2,2,是,0.0,0.0,0.0,93.62,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-04-13 21:00:00,2026-04-14 05:00:00,9,4,是,0.0,0.0,0.0,94.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-04-17 22:00:00,2026-04-17 22:00:00,1,1,是,0.0,0.0,0.0,95.23,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2026-04-18 08:00:00,2026-04-18 08:00:00,1,1,否,61.03,61.03,61.03,86.31,单通道短时骤降并恢复,按通道异常处理,不参与同级温差 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2026-04-18 08:00:00,2026-04-18 08:00:00,1,1,否,60.37,60.37,60.37,85.39,单通道短时骤降并恢复,按通道异常处理,不参与同级温差