回测_温度事件.csv 1.9 KB

12345678910111213
  1. 机组,故障日期,描述,关注级,最大同级偏离℃,最大级差变化℃,命中,首个事件开始,提前小时,命中等级,通道异常命中,通道异常类型,通道异常开始,同日命中
  2. 4号机组,2026-06-10,4#压缩机一级2#3#缸温度异常,一级,6.78,6.0,命中,2026-06-10 02:00,-2.0,异常、轻微,是,停机/通道异常,2026-06-09 12:00,是
  3. 5号机组,2026-03-26,5#机一级1#缸温度高,一级,5.17,8.17,命中,2026-03-26 04:00,-4.0,异常,是,通道骤降,2026-03-25 10:00,是
  4. 5号机组,2026-04-01,5#机一级2#缸温度高,一级,8.56,8.17,命中,2026-03-31 18:00,6.0,异常、轻微,是,通道骤降,2026-03-31 18:00,否
  5. 5号机组,2026-04-08,5#压缩机一级2#缸温度高,一级,10.02,9.73,命中,2026-04-06 14:00,34.0,轻微,否,,,否
  6. 5号机组,2026-06-12,5#压缩机一级2#缸温度异常,一级,10.14,9.41,命中,2026-06-11 12:00,12.0,严重异常,是,停机/通道异常,2026-06-05 03:00,否
  7. 5号机组,2026-06-21,5#压缩机二级2#缸温度异常,二级,9.09,8.75,命中,2026-06-21 01:00,-1.0,异常,否,,,是
  8. 5号机组,2026-07-11,一级二缸排温高停机,一级,,,未命中,,,,否,,,否
  9. 6号机组,2026-01-19,6#压缩机一级1#、3#缸温度高,导机,一级,7.96,9.08,命中,2026-01-18 18:00,6.0,轻微,是,停机/通道异常、通道骤降,2026-01-18 18:00,否
  10. 6号机组,2026-01-30,6#压缩机一级2#缸温度异常导机,一级,13.76,12.47,命中,2026-01-30 08:00,-8.0,异常、轻微,否,,,是
  11. 6号机组,2026-02-18,6#压缩机一级1#排气温度异常导致停机,一级,0.72,0.27,命中,,-21.0,通道异常,是,停机/通道异常、通道坏道,2026-02-18 21:00,是
  12. 6号机组,2026-02-27,6#压缩机一级3#缸温度异常导机,一级,4.78,4.25,命中,2026-02-25 08:00,40.0,轻微,是,停机/通道异常,2026-02-25 08:00,否
  13. 6号机组,2026-04-22,6#机一级3缸排气温度高,一级,10.29,10.17,命中,2026-04-20 07:00,41.0,严重异常,是,停机/通道异常,2026-04-20 07:00,否