温度通道异常段.csv 189 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519520521522523524525526527528529530531532533534535536537538539540541542543544545546547548549550551552553554555556557558559560561562563564565566567568569570571572573574575576577578579580581582583584585586587588589590591592593594595596597598599600601602603604605606607608609610611612613614615616617618619620621622623624625626627628629630631632633634635636637638639640641642643644645646647648649650651652653654655656657658659660661662663664665666667668669670671672673674675676677678679680681682683684685686687688689690691692693694695696697698699700701702703704705706707708709710711712713714715716717718719720721722723724725726727728729730731732733734735736737738739740741742743744745746747748749750751752753754755756757758759760761762763764765766767768769770771772773774775776777778779780781782783784785786787788789790791792793794795796797798799800801802803804805806807808809810811812813814815816817818819820821
  1. 机组,批次,点位,点位描述,级,缸,异常类型,开始小时,结束小时,持续自然小时数,有效小时数,是否显著,最小值,最大值,中位数,同级基准中位,原因
  2. 4号机,56,YSJ_10,一级2#缸排气温度,一级,2#,停机/通道异常,2025-10-20 03:00:00,2025-10-20 04:00:00,2,2,是,0.0,0.0,0.0,106.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  3. 4号机,56,YSJ_10,一级2#缸排气温度,一级,2#,停机/通道异常,2025-10-21 00:00:00,2025-10-21 01:00:00,2,2,是,0.0,0.0,0.0,106.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  4. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-10-22 05:00:00,2025-10-22 07:00:00,3,2,是,0.0,0.0,0.0,108.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  5. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2025-10-22 10:00:00,2025-10-22 11:00:00,2,2,是,0.0,0.0,0.0,104.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  6. 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2025-10-22 21:00:00,2025-10-22 22:00:00,2,2,是,0.0,0.0,0.0,109.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  7. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-10-23 04:00:00,2025-10-23 05:00:00,2,2,是,0.0,0.0,0.0,111.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  8. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-10-23 15:00:00,2025-10-23 18:00:00,4,2,是,0.0,0.0,0.0,112.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  9. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,通道冻值,2025-10-23 20:00:00,2025-10-24 07:00:00,12,12,是,104.0,104.05,104.0,107.9,单通道长期不变而同级其他缸在变化,按冻值处理
  10. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2025-10-24 19:00:00,2025-10-26 08:00:00,38,31,是,0.0,104.07,104.0,107.5,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  11. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2025-10-25 05:00:00,2025-10-25 07:00:00,3,2,是,0.0,0.0,0.0,105.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  12. 4号机,56,YSJ_14,二级2#缸排气温度,二级,2#,停机/通道异常,2025-11-04 21:00:00,2025-11-04 22:00:00,2,2,是,0.0,0.0,0.0,107.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  13. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-06 22:00:00,2025-11-06 22:00:00,1,1,是,0.0,0.0,0.0,101.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  14. 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-07 15:00:00,2025-11-07 17:00:00,3,2,是,0.0,0.0,0.0,102.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  15. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-07 17:00:00,2025-11-07 18:00:00,2,2,是,0.0,0.0,0.0,102.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  16. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-08 22:00:00,2025-11-08 22:00:00,1,1,是,0.0,0.0,0.0,104.52,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  17. 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-09 18:00:00,2025-11-09 19:00:00,2,2,是,0.0,0.0,0.0,101.52,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  18. 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-10 21:00:00,2025-11-10 22:00:00,2,2,是,0.0,0.0,0.0,102.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  19. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2025-11-11 11:00:00,2025-11-11 12:00:00,2,2,是,0.0,0.0,0.0,113.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  20. 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-12 07:00:00,2025-11-12 08:00:00,2,2,是,0.0,0.0,0.0,104.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  21. 4号机,56,YSJ_10,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-16 05:00:00,2025-11-16 07:00:00,3,2,是,0.0,0.0,0.0,100.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  22. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-16 08:00:00,2025-11-16 10:00:00,3,2,是,0.0,0.0,0.0,106.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  23. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-17 18:00:00,2025-11-17 19:00:00,2,2,是,0.0,0.0,0.0,100.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  24. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2025-11-18 00:00:00,2025-11-18 01:00:00,2,2,是,0.0,0.0,0.0,93.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  25. 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,101.97,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  26. 4号机,56,YSJ_10,一级2#缸排气温度,一级,2#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,100.92,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  27. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,102.68,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  28. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,107.44,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  29. 4号机,56,YSJ_14,二级2#缸排气温度,二级,2#,停机/通道异常,2025-11-19 15:00:00,2025-11-19 19:00:00,5,3,是,-0.0,-0.0,0.0,104.71,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  30. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,101.55,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  31. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-20 08:00:00,2025-11-20 10:00:00,3,2,是,0.0,0.0,0.0,106.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  32. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-24 19:00:00,2025-11-24 21:00:00,3,2,是,0.0,0.0,0.0,104.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  33. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-12-07 17:00:00,2025-12-07 18:00:00,2,2,是,0.0,0.0,0.0,112.1,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  34. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2025-12-24 12:00:00,2025-12-24 14:00:00,3,2,是,0.0,0.0,0.0,105.34,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  35. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2025-12-24 21:00:00,2025-12-24 22:00:00,2,2,是,0.0,0.0,0.0,96.99,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  36. 4号机,56,YSJ_10,一级2#缸排气温度,一级,2#,停机/通道异常,2025-12-25 21:00:00,2025-12-25 22:00:00,2,2,是,0.0,0.0,0.0,92.94,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  37. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2025-12-27 08:00:00,2025-12-27 10:00:00,3,2,是,0.0,0.0,0.0,96.52,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  38. 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2025-12-27 18:00:00,2025-12-27 19:00:00,2,2,是,0.0,0.0,0.0,97.61,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  39. 4号机,56,YSJ_14,二级2#缸排气温度,二级,2#,停机/通道异常,2026-01-01 00:00:00,2026-01-01 01:00:00,2,2,是,0.0,0.0,0.0,95.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  40. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-01-01 01:00:00,2026-01-01 03:00:00,3,2,是,0.0,0.0,0.0,94.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  41. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-01-03 04:00:00,2026-01-03 05:00:00,2,2,是,0.0,0.0,0.0,99.46,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  42. 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2026-01-04 17:00:00,2026-01-04 18:00:00,2,2,是,0.0,0.0,0.0,97.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  43. 4号机,56,YSJ_14,二级2#缸排气温度,二级,2#,停机/通道异常,2026-01-06 11:00:00,2026-01-06 12:00:00,2,2,是,0.0,0.0,0.0,98.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  44. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-06 21:00:00,2026-01-06 22:00:00,2,2,是,0.0,0.0,0.0,95.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  45. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-07 14:00:00,2026-01-07 15:00:00,2,2,是,0.0,0.0,0.0,96.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  46. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-01-07 21:00:00,2026-01-08 01:00:00,5,4,是,0.0,0.0,0.0,94.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  47. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-08 17:00:00,2026-01-08 18:00:00,2,2,是,0.0,0.0,0.0,96.93,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  48. 4号机,56,YSJ_14,二级2#缸排气温度,二级,2#,通道骤降,2026-01-09 13:00:00,2026-01-09 13:00:00,1,1,否,86.0,86.0,86.0,106.36,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  49. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-01-15 19:00:00,2026-01-15 21:00:00,3,2,是,0.0,0.0,0.0,106.1,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  50. 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2026-01-16 01:00:00,2026-01-16 03:00:00,3,2,是,0.0,0.0,0.0,96.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  51. 4号机,56,YSJ_10,一级2#缸排气温度,一级,2#,停机/通道异常,2026-01-17 00:00:00,2026-01-17 07:00:00,8,4,是,0.0,0.0,0.0,98.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  52. 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2026-01-17 18:00:00,2026-01-18 15:00:00,22,21,是,0.0,96.0,96.0,97.97,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  53. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-01-17 21:00:00,2026-01-17 22:00:00,2,2,是,0.0,0.0,0.0,97.5,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  54. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,通道冻值,2026-01-18 21:00:00,2026-01-19 08:00:00,12,12,是,97.0,97.09,97.0,98.0,单通道长期不变而同级其他缸在变化,按冻值处理
  55. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-01-19 19:00:00,2026-01-19 21:00:00,3,2,是,0.0,0.0,0.0,92.5,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  56. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-01-21 10:00:00,2026-01-21 11:00:00,2,2,是,0.0,0.0,0.0,91.02,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  57. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-01-22 11:00:00,2026-01-22 12:00:00,2,2,是,0.0,0.0,0.0,99.84,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  58. 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,通道冻值,2026-01-25 13:00:00,2026-01-26 08:00:00,20,20,是,94.0,94.0,94.0,99.5,单通道长期不变而同级其他缸在变化,按冻值处理
  59. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-01-29 00:00:00,2026-01-29 01:00:00,2,2,是,0.0,0.0,0.0,104.09,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  60. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-02-02 01:00:00,2026-02-02 03:00:00,3,2,是,0.0,0.0,0.0,95.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  61. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-02 12:00:00,2026-02-02 14:00:00,3,2,是,0.0,0.0,0.0,106.19,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  62. 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2026-02-03 01:00:00,2026-02-03 03:00:00,3,2,是,0.0,0.0,0.0,94.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  63. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2026-02-05 14:00:00,2026-02-05 15:00:00,2,2,是,0.0,0.0,0.0,104.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  64. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,通道骤降,2026-02-13 07:00:00,2026-02-13 08:00:00,2,2,是,100.41,103.87,102.14,111.25,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  65. 4号机,56,YSJ_14,二级2#缸排气温度,二级,2#,通道骤降,2026-02-13 07:00:00,2026-02-13 07:00:00,1,1,否,97.5,97.5,97.5,107.45,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  66. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,通道骤降,2026-02-13 07:00:00,2026-02-13 08:00:00,2,2,是,94.8,98.54,96.67,106.03,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  67. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-14 15:00:00,2026-02-14 17:00:00,3,2,是,0.0,0.0,0.0,112.41,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  68. 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2026-02-16 22:00:00,2026-02-16 22:00:00,1,1,是,0.0,0.0,0.0,94.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  69. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2026-02-19 04:00:00,2026-02-19 05:00:00,2,2,是,0.0,0.0,0.0,100.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  70. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-19 12:00:00,2026-02-19 14:00:00,3,2,是,0.0,0.0,0.0,110.32,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  71. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,通道冻值,2026-02-27 13:00:00,2026-02-28 01:00:00,13,13,是,100.97,101.0,101.0,97.72,单通道长期不变而同级其他缸在变化,按冻值处理
  72. 4号机,56,YSJ_10,一级2#缸排气温度,一级,2#,通道冻值,2026-02-27 15:00:00,2026-02-28 06:00:00,16,16,是,100.0,100.0,100.0,97.78,单通道长期不变而同级其他缸在变化,按冻值处理
  73. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-02-28 03:00:00,2026-02-28 04:00:00,2,2,是,0.0,0.0,0.0,97.07,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  74. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-28 11:00:00,2026-02-28 12:00:00,2,2,是,0.0,0.0,0.0,103.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  75. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-03-01 17:00:00,2026-03-01 18:00:00,2,2,是,0.0,0.0,0.0,97.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  76. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-03-02 08:00:00,2026-03-02 11:00:00,4,2,是,0.0,0.0,0.0,103.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  77. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,通道冻值,2026-03-02 17:00:00,2026-03-03 08:00:00,16,16,是,102.0,102.08,102.0,98.78,单通道长期不变而同级其他缸在变化,按冻值处理
  78. 4号机,56,YSJ_14,二级2#缸排气温度,二级,2#,停机/通道异常,2026-03-02 17:00:00,2026-03-02 18:00:00,2,2,是,0.0,0.0,0.0,101.4,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  79. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-03-02 18:00:00,2026-03-02 19:00:00,2,2,是,0.0,0.0,0.0,104.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  80. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-04-06 21:00:00,2026-04-06 22:00:00,2,2,是,0.0,0.0,0.0,112.58,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  81. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-04-07 12:00:00,2026-04-07 14:00:00,3,2,是,0.0,0.0,0.0,115.2,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  82. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-04-23 04:00:00,2026-04-23 05:00:00,2,2,是,0.0,0.0,0.0,102.15,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  83. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2026-04-30 22:00:00,2026-04-30 22:00:00,1,1,是,0.0,0.0,0.0,110.31,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  84. 4号机,56,YSJ_13,二级1#缸排气温度,二级,1#,停机/通道异常,2026-05-30 08:00:00,2026-05-30 15:00:00,8,3,是,0.0,0.0,0.0,118.61,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  85. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,通道坏道,2026-05-30 15:00:00,2026-05-30 15:00:00,1,1,是,-0.0,-0.0,-0.0,119.6,单通道长期接近环境温度,按坏道处理
  86. 4号机,56,YSJ_9,一级1#缸排气温度,一级,1#,停机/通道异常,2026-06-07 10:00:00,2026-06-07 11:00:00,2,2,是,0.0,0.0,0.0,111.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  87. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-06-08 00:00:00,2026-06-08 01:00:00,2,2,是,0.0,0.0,0.0,112.45,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  88. 4号机,56,YSJ_15,二级3#缸排气温度,二级,3#,停机/通道异常,2026-06-09 12:00:00,2026-06-09 14:00:00,3,2,是,0.0,0.0,0.0,123.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  89. 4号机,56,YSJ_11,一级3#缸排气温度,一级,3#,停机/通道异常,2026-06-13 18:00:00,2026-06-13 19:00:00,2,2,是,0.0,0.0,0.0,114.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  90. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-01-22 05:00:00,2025-01-22 07:00:00,3,2,是,0.0,0.0,0.0,88.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  91. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-02-13 10:00:00,2025-02-13 11:00:00,2,2,是,98.65,102.51,100.58,111.79,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  92. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-02-13 10:00:00,2025-02-13 11:00:00,2,2,是,99.89,103.78,101.84,113.16,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  93. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-02-13 10:00:00,2025-02-13 11:00:00,2,2,是,99.26,103.13,101.19,112.44,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  94. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-03-04 22:00:00,2025-03-04 22:00:00,1,1,是,0.0,0.0,0.0,107.19,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  95. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-03-11 08:00:00,2025-03-11 10:00:00,3,2,是,0.0,0.0,0.0,108.58,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  96. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-03-13 04:00:00,2025-03-13 05:00:00,2,2,是,0.0,0.0,0.0,92.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  97. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-03-14 04:00:00,2025-03-14 05:00:00,2,2,是,0.0,0.0,0.0,92.02,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  98. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-03-14 07:00:00,2025-03-14 08:00:00,2,2,是,0.0,0.0,0.0,95.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  99. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-03-16 01:00:00,2025-03-16 03:00:00,3,2,是,0.0,0.0,0.0,93.27,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  100. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-03-16 01:00:00,2025-03-16 03:00:00,3,2,是,0.0,0.0,0.0,90.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  101. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-03-16 18:00:00,2025-03-16 19:00:00,2,2,是,0.0,0.0,0.0,96.63,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  102. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-03-17 00:00:00,2025-03-17 01:00:00,2,2,是,0.0,0.0,0.0,89.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  103. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-03-19 04:00:00,2025-03-19 05:00:00,2,2,是,0.0,0.0,0.0,91.31,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  104. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-03-29 11:00:00,2025-03-29 12:00:00,2,2,是,0.0,0.0,0.0,109.83,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  105. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-03-31 03:00:00,2025-03-31 04:00:00,2,2,是,0.0,0.0,0.0,90.71,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  106. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-04-01 22:00:00,2025-04-01 22:00:00,1,1,是,0.0,0.0,0.0,116.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  107. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-04-03 07:00:00,2025-04-03 08:00:00,2,2,是,0.0,0.0,0.0,95.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  108. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-04-05 11:00:00,2025-04-05 12:00:00,2,2,是,0.0,0.0,0.0,100.21,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  109. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-04-08 00:00:00,2025-04-08 01:00:00,2,2,是,0.0,0.0,0.0,113.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  110. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-04-10 10:00:00,2025-04-10 11:00:00,2,2,是,0.0,0.0,0.0,99.93,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  111. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-04-14 01:00:00,2025-04-14 03:00:00,3,2,是,0.0,0.0,0.0,96.93,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  112. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-04-14 14:00:00,2025-04-14 15:00:00,2,2,是,0.0,0.0,0.0,104.38,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  113. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2025-04-17 15:00:00,2025-04-17 15:00:00,1,1,否,9.46,9.46,9.46,110.7,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  114. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2025-04-17 15:00:00,2025-04-17 15:00:00,1,1,否,9.46,9.46,9.46,110.64,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  115. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2025-04-17 15:00:00,2025-04-17 15:00:00,1,1,否,9.48,9.48,9.48,110.76,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  116. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-04-17 15:00:00,2025-04-17 15:00:00,1,1,否,11.38,11.38,11.38,133.71,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  117. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-04-17 15:00:00,2025-04-17 15:00:00,1,1,否,11.49,11.49,11.49,135.02,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  118. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-04-17 15:00:00,2025-04-17 15:00:00,1,1,否,11.42,11.42,11.42,134.09,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  119. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-04-17 22:00:00,2025-04-17 22:00:00,1,1,是,0.0,0.0,0.0,104.43,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  120. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2025-04-18 17:00:00,2025-04-18 17:00:00,1,1,否,103.08,103.08,103.08,111.14,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  121. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-05-22 01:00:00,2025-05-22 03:00:00,3,2,是,0.0,0.0,0.0,121.23,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  122. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-05-24 10:00:00,2025-05-24 11:00:00,2,2,是,0.0,0.0,0.0,106.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  123. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-05-25 14:00:00,2025-05-25 15:00:00,2,2,是,0.0,0.0,0.0,102.63,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  124. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-05-27 12:00:00,2025-05-27 14:00:00,3,2,是,0.0,0.0,0.0,108.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  125. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-05-27 15:00:00,2025-05-27 17:00:00,3,2,是,0.0,0.0,0.0,121.87,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  126. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-05-27 19:00:00,2025-05-27 21:00:00,3,2,是,0.0,0.0,0.0,103.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  127. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-05-28 19:00:00,2025-05-28 21:00:00,3,2,是,0.0,0.0,0.0,105.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  128. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-05-28 21:00:00,2025-05-28 22:00:00,2,2,是,0.0,0.0,0.0,117.45,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  129. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-05-29 01:00:00,2025-05-29 03:00:00,3,2,是,0.0,0.0,0.0,101.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  130. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-05-30 07:00:00,2025-05-30 14:00:00,8,3,是,0.0,99.72,0.0,120.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  131. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-05-30 11:00:00,2025-05-30 14:00:00,4,2,是,0.0,0.0,0.0,105.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  132. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-05-30 14:00:00,2025-05-30 14:00:00,1,1,否,97.96,97.96,97.96,122.06,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  133. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-05-30 14:00:00,2025-05-30 14:00:00,1,1,否,98.75,98.75,98.75,122.45,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  134. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-05-31 05:00:00,2025-05-31 07:00:00,3,2,是,0.0,0.0,0.0,100.84,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  135. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-06-12 08:00:00,2025-06-12 10:00:00,3,2,是,0.0,0.0,0.0,112.54,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  136. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-07-02 01:00:00,2025-07-02 03:00:00,3,2,是,0.0,0.0,0.0,106.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  137. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-07-05 05:00:00,2025-07-05 07:00:00,3,2,是,0.0,0.0,0.0,110.23,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  138. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-07-05 17:00:00,2025-07-05 18:00:00,2,2,是,0.0,0.0,0.0,128.85,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  139. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-07-06 07:00:00,2025-07-06 08:00:00,2,2,是,0.0,0.0,0.0,123.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  140. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-07-10 03:00:00,2025-07-10 04:00:00,2,2,是,0.0,0.0,0.0,125.38,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  141. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2025-07-10 16:00:00,2025-07-10 16:00:00,1,1,否,-0.0,-0.0,-0.0,112.43,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  142. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2025-07-10 16:00:00,2025-07-10 16:00:00,1,1,否,-0.0,-0.0,-0.0,113.94,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  143. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2025-07-10 16:00:00,2025-07-10 16:00:00,1,1,否,-0.0,-0.0,-0.0,114.11,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  144. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-07-10 16:00:00,2025-07-10 16:00:00,1,1,否,-0.0,-0.0,-0.0,130.83,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  145. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-07-10 16:00:00,2025-07-10 16:00:00,1,1,否,-0.0,-0.0,-0.0,132.58,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  146. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-07-10 16:00:00,2025-07-10 16:00:00,1,1,否,-0.0,-0.0,-0.0,131.15,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  147. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-07-11 19:00:00,2025-07-11 21:00:00,3,2,是,0.0,0.0,0.0,127.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  148. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-08-25 21:00:00,2025-08-25 21:00:00,1,1,是,0.0,0.0,0.0,123.23,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  149. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-08-26 12:00:00,2025-08-26 14:00:00,3,2,是,0.0,0.0,0.0,109.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  150. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-08-26 21:00:00,2025-08-26 22:00:00,2,2,是,0.0,0.0,0.0,108.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  151. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-08-29 11:00:00,2025-08-29 12:00:00,2,2,是,0.0,0.0,0.0,121.04,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  152. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-08-30 12:00:00,2025-08-30 14:00:00,3,2,是,0.0,0.0,0.0,107.76,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  153. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-09-12 03:00:00,2025-09-12 04:00:00,2,2,是,0.0,0.0,0.0,118.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  154. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-09-17 01:00:00,2025-09-17 03:00:00,3,2,是,0.0,0.0,0.0,104.69,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  155. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-09-17 11:00:00,2025-09-17 12:00:00,2,2,是,0.0,0.0,0.0,116.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  156. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-09-17 21:00:00,2025-09-17 22:00:00,2,2,是,0.0,0.0,0.0,113.95,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  157. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-10-27 01:00:00,2025-10-27 03:00:00,3,2,是,0.0,0.0,0.0,106.4,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  158. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-01 10:00:00,2025-11-01 11:00:00,2,2,是,0.0,0.0,0.0,102.62,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  159. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-15 15:00:00,2025-11-15 16:00:00,2,2,是,-0.0,-0.0,-0.0,103.69,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  160. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-15 15:00:00,2025-11-15 16:00:00,2,2,是,-0.0,-0.0,-0.0,101.51,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  161. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-15 15:00:00,2025-11-15 16:00:00,2,2,是,-0.0,-0.0,-0.0,105.11,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  162. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-15 15:00:00,2025-11-15 16:00:00,2,2,是,-0.0,-0.0,-0.0,117.55,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  163. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-11-15 15:00:00,2025-11-15 16:00:00,2,2,是,-0.0,-0.0,-0.0,118.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  164. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-11-15 15:00:00,2025-11-15 16:00:00,2,2,是,-0.0,-0.0,-0.0,118.74,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  165. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-16 07:00:00,2025-11-16 08:00:00,2,2,是,0.0,0.0,0.0,108.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  166. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-16 10:00:00,2025-11-16 11:00:00,2,2,是,0.0,0.0,0.0,102.63,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  167. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-16 18:00:00,2025-11-16 19:00:00,2,2,是,0.0,0.0,0.0,101.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  168. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2025-11-17 10:00:00,2025-11-17 15:00:00,6,2,是,8.05,8.13,8.09,96.72,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  169. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2025-11-17 10:00:00,2025-11-17 15:00:00,6,2,是,7.91,7.97,7.94,94.7,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  170. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2025-11-17 10:00:00,2025-11-17 15:00:00,6,2,是,8.22,8.29,8.25,98.44,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  171. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-11-17 10:00:00,2025-11-17 15:00:00,6,2,是,8.73,8.9,8.82,105.79,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  172. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-11-17 10:00:00,2025-11-17 15:00:00,6,2,是,8.78,8.93,8.85,106.16,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  173. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-11-17 10:00:00,2025-11-17 15:00:00,6,2,是,8.84,8.99,8.92,106.97,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  174. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-11-19 01:00:00,2025-11-19 03:00:00,3,2,是,0.0,0.0,0.0,105.33,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  175. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-25 11:00:00,2025-11-25 12:00:00,2,2,是,0.0,0.0,0.0,108.97,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  176. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-30 07:00:00,2025-11-30 08:00:00,2,2,是,0.0,0.0,0.0,95.5,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  177. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-30 08:00:00,2025-11-30 10:00:00,3,2,是,0.0,0.0,0.0,105.51,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  178. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-12-08 00:00:00,2025-12-08 01:00:00,2,2,是,0.0,0.0,0.0,116.35,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  179. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-12-08 01:00:00,2025-12-08 03:00:00,3,2,是,0.0,0.0,0.0,92.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  180. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-12-11 15:00:00,2025-12-11 17:00:00,3,2,是,0.0,0.0,0.0,91.76,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  181. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-12-12 12:00:00,2025-12-12 14:00:00,3,2,是,0.0,0.0,0.0,95.29,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  182. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-12-22 12:00:00,2025-12-22 14:00:00,3,2,是,0.0,0.0,0.0,104.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  183. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-12-22 15:00:00,2025-12-22 17:00:00,3,2,是,0.0,0.0,0.0,105.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  184. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-12-23 21:00:00,2025-12-23 22:00:00,2,2,是,0.0,0.0,0.0,90.53,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  185. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-01-14 21:00:00,2026-01-14 22:00:00,2,2,是,0.0,0.0,0.0,106.8,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  186. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-01-15 05:00:00,2026-01-15 07:00:00,3,2,是,0.0,0.0,0.0,105.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  187. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-16 17:00:00,2026-01-16 18:00:00,2,2,是,0.0,0.0,0.0,95.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  188. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-01-22 11:00:00,2026-01-22 12:00:00,2,2,是,0.0,0.0,0.0,91.46,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  189. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-23 14:00:00,2026-01-23 15:00:00,2,2,是,0.0,0.0,0.0,92.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  190. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-31 07:00:00,2026-01-31 08:00:00,2,2,是,0.0,0.0,0.0,90.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  191. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-02-03 01:00:00,2026-02-03 03:00:00,3,2,是,0.0,0.0,0.0,93.52,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  192. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-02-03 10:00:00,2026-02-03 15:00:00,6,4,是,0.0,0.0,0.0,105.02,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  193. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-02-06 00:00:00,2026-02-06 01:00:00,2,2,是,0.0,0.0,0.0,104.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  194. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-02-07 08:00:00,2026-02-07 10:00:00,3,2,是,0.0,0.0,0.0,102.99,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  195. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-02-08 04:00:00,2026-02-08 05:00:00,2,2,是,0.0,0.0,0.0,99.38,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  196. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-02-10 12:00:00,2026-02-10 14:00:00,3,2,是,0.0,0.0,0.0,110.69,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  197. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-10 21:00:00,2026-02-10 22:00:00,2,2,是,0.0,0.0,0.0,104.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  198. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-12 10:00:00,2026-02-12 11:00:00,2,2,是,0.0,0.0,0.0,107.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  199. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-02-18 04:00:00,2026-02-18 05:00:00,2,2,是,0.0,0.0,0.0,102.93,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  200. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-02-19 07:00:00,2026-02-19 08:00:00,2,2,是,0.0,0.0,0.0,89.54,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  201. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-02-24 14:00:00,2026-02-24 15:00:00,2,2,是,0.0,0.0,0.0,92.92,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  202. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-02-27 17:00:00,2026-02-27 18:00:00,2,2,是,0.0,0.0,0.0,91.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  203. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-02-28 01:00:00,2026-02-28 03:00:00,3,2,是,0.0,0.0,0.0,90.76,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  204. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-03-03 21:00:00,2026-03-03 22:00:00,2,2,是,0.0,0.0,0.0,92.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  205. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-03-06 18:00:00,2026-03-06 19:00:00,2,2,是,0.0,0.0,0.0,105.04,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  206. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-03-06 19:00:00,2026-03-06 21:00:00,3,2,是,0.0,0.0,0.0,89.47,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  207. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-03-09 01:00:00,2026-03-09 03:00:00,3,2,是,0.0,0.0,0.0,95.75,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  208. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-03-09 14:00:00,2026-03-09 15:00:00,2,2,是,0.0,0.0,0.0,110.83,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  209. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-03-10 21:00:00,2026-03-10 22:00:00,2,2,是,0.0,0.0,0.0,108.74,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  210. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-03-13 11:00:00,2026-03-13 12:00:00,2,2,是,0.0,0.0,0.0,118.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  211. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2026-03-25 10:00:00,2026-03-25 10:00:00,1,1,否,118.07,118.07,118.07,126.08,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  212. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2026-03-31 18:00:00,2026-03-31 19:00:00,2,2,是,7.55,7.64,7.6,91.42,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  213. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2026-03-31 18:00:00,2026-03-31 19:00:00,2,2,是,8.18,8.27,8.22,98.85,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  214. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2026-03-31 18:00:00,2026-03-31 19:00:00,2,2,是,7.55,7.64,7.6,91.35,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  215. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2026-03-31 18:00:00,2026-03-31 19:00:00,2,2,是,8.95,9.06,9.01,107.73,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  216. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2026-03-31 18:00:00,2026-03-31 19:00:00,2,2,是,9.08,9.2,9.14,109.36,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  217. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2026-03-31 18:00:00,2026-03-31 19:00:00,2,2,是,9.02,9.13,9.07,108.54,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  218. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-04-14 17:00:00,2026-04-14 18:00:00,2,2,是,0.0,0.0,0.0,98.84,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  219. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-04-14 19:00:00,2026-04-14 21:00:00,3,2,是,0.0,0.0,0.0,96.61,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  220. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-04-15 18:00:00,2026-04-15 19:00:00,2,2,是,0.0,0.0,0.0,114.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  221. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-04-17 01:00:00,2026-04-17 03:00:00,3,2,是,0.0,0.0,0.0,93.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  222. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-05-02 08:00:00,2026-05-02 10:00:00,3,2,是,0.0,0.0,0.0,99.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  223. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-05-05 07:00:00,2026-05-05 08:00:00,2,2,是,0.0,0.0,0.0,113.25,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  224. 5号机,58,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-05-05 19:00:00,2026-05-05 21:00:00,3,2,是,0.0,0.0,0.0,100.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  225. 5号机,58,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-05-05 21:00:00,2026-05-05 22:00:00,2,2,是,0.0,0.0,0.0,99.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  226. 5号机,58,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-05-07 11:00:00,2026-05-07 12:00:00,2,2,是,0.0,0.0,0.0,103.84,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  227. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-05-09 01:00:00,2026-05-09 03:00:00,3,2,是,0.0,0.0,0.0,110.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  228. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-06-05 03:00:00,2026-06-05 04:00:00,2,2,是,0.0,0.0,0.0,117.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  229. 5号机,58,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2026-06-30 19:00:00,2026-06-30 20:00:00,2,2,是,109.24,118.31,113.77,128.75,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  230. 5号机,58,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2026-06-30 19:00:00,2026-06-30 20:00:00,2,2,是,110.81,119.7,115.26,130.23,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  231. 5号机,58,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2026-06-30 19:00:00,2026-06-30 20:00:00,2,2,是,118.87,119.04,118.95,129.3,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  232. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-01-18 00:00:00,2025-01-18 01:00:00,2,2,是,0.0,0.0,0.0,88.19,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  233. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-02-15 08:00:00,2025-02-15 09:00:00,2,2,是,96.31,99.51,97.91,106.96,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  234. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-02-15 08:00:00,2025-02-15 09:00:00,2,2,是,96.91,100.11,98.51,107.63,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  235. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-02-15 08:00:00,2025-02-15 09:00:00,2,2,是,95.74,99.03,97.39,106.65,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  236. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-02-24 22:00:00,2025-02-24 22:00:00,1,1,是,0.0,0.0,0.0,100.62,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  237. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-02-27 05:00:00,2025-02-27 07:00:00,3,2,是,0.0,0.0,0.0,100.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  238. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-02-27 22:00:00,2025-02-27 22:00:00,1,1,是,0.0,0.0,0.0,91.85,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  239. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-03-01 11:00:00,2025-03-01 12:00:00,2,2,是,0.0,0.0,0.0,98.41,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  240. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-03-02 05:00:00,2025-03-02 07:00:00,3,2,是,0.0,0.0,0.0,106.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  241. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-03-02 18:00:00,2025-03-02 19:00:00,2,2,是,0.0,0.0,0.0,102.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  242. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-03-02 19:00:00,2025-03-02 21:00:00,3,2,是,0.0,0.0,0.0,90.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  243. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-05-31 14:00:00,2025-05-31 15:00:00,2,2,是,0.0,0.0,0.0,106.35,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  244. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-06-01 10:00:00,2025-06-01 11:00:00,2,2,是,0.0,0.0,0.0,116.03,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  245. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-06-02 04:00:00,2025-06-02 04:00:00,1,1,否,90.67,90.67,90.67,112.7,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  246. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-06-02 04:00:00,2025-06-02 04:00:00,1,1,否,90.88,90.88,90.88,113.23,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  247. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-06-02 04:00:00,2025-06-02 04:00:00,1,1,否,89.69,89.69,89.69,112.14,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  248. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-06-17 03:00:00,2025-06-17 04:00:00,2,2,是,0.0,0.0,0.0,113.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  249. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-06-18 11:00:00,2025-06-18 12:00:00,2,2,是,0.0,0.0,0.0,107.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  250. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-06-21 00:00:00,2025-06-21 01:00:00,2,2,是,0.0,0.0,0.0,104.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  251. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2025-06-22 09:00:00,2025-06-22 09:00:00,1,1,否,18.45,18.45,18.45,110.48,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  252. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2025-06-22 09:00:00,2025-06-22 09:00:00,1,1,否,18.51,18.51,18.51,110.84,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  253. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2025-06-22 09:00:00,2025-06-22 09:00:00,1,1,否,18.4,18.4,18.4,110.15,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  254. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-06-22 09:00:00,2025-06-22 09:00:00,1,1,否,20.58,20.58,20.58,123.39,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  255. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-06-22 09:00:00,2025-06-22 09:00:00,1,1,否,20.68,20.68,20.68,123.91,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  256. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-06-22 09:00:00,2025-06-22 09:00:00,1,1,否,20.52,20.52,20.52,123.01,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  257. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-06-27 00:00:00,2025-06-27 01:00:00,2,2,是,0.0,0.0,0.0,104.29,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  258. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-07-18 00:00:00,2025-07-18 01:00:00,2,2,是,0.0,0.0,0.0,109.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  259. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2025-08-01 09:00:00,2025-08-01 09:00:00,1,1,否,18.75,18.75,18.75,113.39,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  260. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2025-08-01 09:00:00,2025-08-01 09:00:00,1,1,否,18.77,18.77,18.77,113.54,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  261. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2025-08-01 09:00:00,2025-08-01 09:00:00,1,1,否,18.62,18.62,18.62,112.66,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  262. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-08-01 09:00:00,2025-08-01 09:00:00,1,1,否,21.01,21.01,21.01,126.82,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  263. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-08-01 09:00:00,2025-08-01 09:00:00,1,1,否,21.06,21.06,21.06,127.24,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  264. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-08-01 09:00:00,2025-08-01 09:00:00,1,1,否,20.94,20.94,20.94,126.48,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  265. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-08-03 19:00:00,2025-08-03 21:00:00,3,2,是,0.0,0.0,0.0,128.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  266. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-08-13 03:00:00,2025-08-13 04:00:00,2,2,是,0.0,0.0,0.0,109.74,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  267. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-08-23 22:00:00,2025-08-23 22:00:00,1,1,是,0.0,0.0,0.0,108.65,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  268. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-08-31 19:00:00,2025-08-31 21:00:00,3,2,是,0.0,0.0,0.0,122.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  269. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-09-03 21:00:00,2025-09-03 22:00:00,2,2,是,0.0,0.0,0.0,104.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  270. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-09-08 15:00:00,2025-09-08 17:00:00,3,2,是,0.0,0.0,0.0,123.27,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  271. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-09-09 03:00:00,2025-09-09 04:00:00,2,2,是,0.0,0.0,0.0,116.53,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  272. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-09-19 04:00:00,2025-09-19 05:00:00,2,2,是,0.0,0.0,0.0,109.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  273. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-09-21 21:00:00,2025-09-21 22:00:00,2,2,是,0.0,0.0,0.0,108.25,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  274. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-09-23 11:00:00,2025-09-23 11:00:00,1,1,否,90.13,90.13,90.13,112.55,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  275. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-09-23 11:00:00,2025-09-23 11:00:00,1,1,否,90.18,90.18,90.18,112.94,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  276. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-09-23 11:00:00,2025-09-23 11:00:00,1,1,否,89.6,89.6,89.6,112.39,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  277. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-10-07 17:00:00,2025-10-07 18:00:00,2,2,是,0.0,0.0,0.0,115.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  278. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-10-11 19:00:00,2025-10-11 21:00:00,3,2,是,0.0,0.0,0.0,101.63,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  279. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-10-14 15:00:00,2025-10-14 17:00:00,3,2,是,0.0,0.0,0.0,102.21,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  280. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-10-16 05:00:00,2025-10-16 07:00:00,3,2,是,0.0,0.0,0.0,113.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  281. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-10-20 12:00:00,2025-10-20 14:00:00,3,2,是,0.0,0.0,0.0,98.04,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  282. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-10-23 12:00:00,2025-10-23 14:00:00,3,2,是,0.0,0.0,0.0,100.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  283. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-10-29 17:00:00,2025-10-29 18:00:00,2,2,是,0.0,0.0,0.0,119.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  284. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-10-30 08:00:00,2025-10-30 10:00:00,3,2,是,0.0,0.0,0.0,102.66,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  285. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-10-30 08:00:00,2025-10-30 10:00:00,3,2,是,0.0,0.0,0.0,104.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  286. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-10-31 04:00:00,2025-10-31 05:00:00,2,2,是,0.0,0.0,0.0,100.37,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  287. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-03 18:00:00,2025-11-03 19:00:00,2,2,是,0.0,0.0,0.0,98.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  288. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-11-06 04:00:00,2025-11-06 05:00:00,2,2,是,0.0,0.0,0.0,110.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  289. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-07 08:00:00,2025-11-07 10:00:00,3,2,是,0.0,0.0,0.0,110.32,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  290. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-08 22:00:00,2025-11-08 22:00:00,1,1,是,0.0,0.0,0.0,95.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  291. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-10 09:00:00,2025-11-10 15:00:00,7,2,是,-0.0,-0.0,-0.0,97.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  292. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-10 09:00:00,2025-11-10 15:00:00,7,2,是,-0.0,-0.0,-0.0,97.23,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  293. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-10 09:00:00,2025-11-10 15:00:00,7,2,是,-0.0,-0.0,-0.0,98.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  294. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-10 09:00:00,2025-11-10 15:00:00,7,2,是,-0.0,-0.0,-0.0,109.15,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  295. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-11-10 09:00:00,2025-11-10 15:00:00,7,2,是,-0.0,-0.0,-0.0,109.15,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  296. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-11-10 09:00:00,2025-11-10 15:00:00,7,2,是,-0.0,-0.0,-0.0,108.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  297. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-11 17:00:00,2025-11-11 17:00:00,1,1,是,-0.0,-0.0,-0.0,106.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  298. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-11 17:00:00,2025-11-11 17:00:00,1,1,是,-0.0,-0.0,-0.0,105.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  299. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-11 17:00:00,2025-11-11 17:00:00,1,1,是,-0.0,-0.0,-0.0,107.41,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  300. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-11 17:00:00,2025-11-11 17:00:00,1,1,是,-0.0,-0.0,-0.0,124.23,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  301. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-11-11 17:00:00,2025-11-11 17:00:00,1,1,是,-0.0,-0.0,-0.0,124.34,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  302. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-11-11 17:00:00,2025-11-11 17:00:00,1,1,是,-0.0,-0.0,-0.0,130.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  303. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-12 11:00:00,2025-11-12 11:00:00,1,1,是,-0.0,-0.0,-0.0,104.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  304. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-11-12 11:00:00,2025-11-12 11:00:00,1,1,是,-0.0,-0.0,-0.0,103.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  305. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-11-12 11:00:00,2025-11-12 11:00:00,1,1,是,-0.0,-0.0,-0.0,105.46,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  306. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-11-12 11:00:00,2025-11-12 11:00:00,1,1,是,-0.0,-0.0,-0.0,118.97,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  307. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-11-12 11:00:00,2025-11-12 11:00:00,1,1,是,-0.0,-0.0,-0.0,118.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  308. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-11-12 11:00:00,2025-11-12 11:00:00,1,1,是,-0.0,-0.0,-0.0,124.12,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  309. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,97.29,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  310. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,96.27,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  311. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,97.71,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  312. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,110.94,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  313. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,111.06,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  314. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-11-19 15:00:00,2025-11-19 15:00:00,1,1,否,-0.0,-0.0,-0.0,110.51,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  315. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-11-22 22:00:00,2025-11-22 22:00:00,1,1,是,0.0,0.0,0.0,97.99,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  316. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-11-22 22:00:00,2025-11-22 22:00:00,1,1,否,84.24,84.24,84.24,110.51,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  317. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-11-22 22:00:00,2025-11-22 22:00:00,1,1,否,84.32,84.32,84.32,110.64,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  318. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-11-22 22:00:00,2025-11-22 22:00:00,1,1,否,83.53,83.53,83.53,109.73,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  319. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2025-12-08 21:00:00,2025-12-08 22:00:00,2,2,是,0.0,0.0,0.0,93.61,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  320. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2025-12-08 22:00:00,2025-12-08 22:00:00,1,1,是,0.0,0.0,0.0,109.58,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  321. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-12-12 00:00:00,2025-12-12 01:00:00,2,2,是,0.0,0.0,0.0,101.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  322. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2025-12-13 19:00:00,2025-12-13 21:00:00,3,2,是,0.0,0.0,0.0,92.99,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  323. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-12-14 03:00:00,2025-12-14 04:00:00,2,2,是,0.0,0.0,0.0,103.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  324. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-12-16 15:00:00,2025-12-16 17:00:00,3,2,是,0.0,0.0,0.0,114.47,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  325. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2025-12-18 04:00:00,2025-12-18 05:00:00,2,2,是,0.0,0.0,0.0,107.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  326. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2025-12-26 09:00:00,2025-12-26 09:00:00,1,1,否,101.74,101.74,101.74,110.61,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  327. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2025-12-26 09:00:00,2025-12-26 09:00:00,1,1,否,102.1,102.1,102.1,111.04,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  328. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2025-12-26 09:00:00,2025-12-26 09:00:00,1,1,否,101.12,101.12,101.12,110.12,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  329. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2025-12-28 14:00:00,2025-12-28 15:00:00,2,2,是,0.0,0.0,0.0,96.18,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  330. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2025-12-29 11:00:00,2025-12-29 12:00:00,2,2,是,0.0,0.0,0.0,107.19,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  331. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2026-01-03 09:00:00,2026-01-03 09:00:00,1,1,否,-0.0,-0.0,-0.0,90.05,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  332. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2026-01-03 09:00:00,2026-01-03 09:00:00,1,1,否,-0.0,-0.0,-0.0,89.44,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  333. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,通道骤降,2026-01-03 09:00:00,2026-01-03 09:00:00,1,1,否,-0.0,-0.0,-0.0,91.97,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  334. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2026-01-03 09:00:00,2026-01-03 09:00:00,1,1,否,-0.0,-0.0,-0.0,103.4,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  335. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2026-01-03 09:00:00,2026-01-03 09:00:00,1,1,否,-0.0,-0.0,-0.0,103.52,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  336. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2026-01-03 09:00:00,2026-01-03 09:00:00,1,1,否,-0.0,-0.0,-0.0,102.56,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  337. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-09 05:00:00,2026-01-09 14:00:00,10,4,是,0.0,67.52,33.38,93.87,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  338. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,通道骤降,2026-01-09 13:00:00,2026-01-09 14:00:00,2,2,是,66.17,67.12,66.65,94.22,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  339. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,通道骤降,2026-01-09 13:00:00,2026-01-09 14:00:00,2,2,是,68.05,68.65,68.35,92.26,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  340. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2026-01-09 13:00:00,2026-01-09 14:00:00,2,2,是,84.8,85.19,84.99,115.19,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  341. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2026-01-09 13:00:00,2026-01-09 14:00:00,2,2,是,86.32,86.39,86.36,115.4,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  342. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2026-01-09 13:00:00,2026-01-09 14:00:00,2,2,是,85.23,85.31,85.27,114.88,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  343. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-01-10 01:00:00,2026-01-10 03:00:00,3,2,是,0.0,0.0,0.0,92.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  344. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-01-10 04:00:00,2026-01-10 05:00:00,2,2,是,0.0,0.0,0.0,108.34,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  345. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-01-16 21:00:00,2026-01-16 22:00:00,2,2,是,0.0,0.0,0.0,93.1,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  346. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道骤降,2026-01-17 09:00:00,2026-01-17 09:00:00,1,1,否,98.69,98.69,98.69,106.89,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  347. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道骤降,2026-01-17 09:00:00,2026-01-17 09:00:00,1,1,否,98.51,98.51,98.51,106.55,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  348. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道骤降,2026-01-17 09:00:00,2026-01-17 09:00:00,1,1,否,97.9,97.9,97.9,106.15,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  349. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-01-18 08:00:00,2026-01-18 10:00:00,3,2,是,0.0,0.0,0.0,89.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  350. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-01-18 08:00:00,2026-01-18 10:00:00,3,2,是,0.0,0.0,0.0,92.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  351. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-01-18 18:00:00,2026-01-18 19:00:00,2,2,是,0.0,0.0,0.0,102.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  352. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-07 18:00:00,2026-02-07 19:00:00,2,2,是,0.0,0.0,0.0,109.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  353. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-02-08 17:00:00,2026-02-08 18:00:00,2,2,是,0.0,0.0,0.0,92.07,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  354. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-02-11 05:00:00,2026-02-11 07:00:00,3,2,是,0.0,0.0,0.0,88.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  355. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-02-15 03:00:00,2026-02-15 04:00:00,2,2,是,0.0,0.0,0.0,103.92,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  356. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-16 03:00:00,2026-02-16 04:00:00,2,2,是,0.0,0.0,0.0,108.12,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  357. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-02-16 15:00:00,2026-02-16 17:00:00,3,2,是,0.0,0.0,0.0,90.03,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  358. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-17 19:00:00,2026-02-17 21:00:00,3,2,是,0.0,0.0,0.0,114.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  359. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-02-17 22:00:00,2026-02-17 22:00:00,1,1,是,0.0,0.0,0.0,94.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  360. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,通道坏道,2026-02-18 21:00:00,2026-02-18 21:00:00,1,1,是,-0.0,-0.0,-0.0,96.13,单通道长期接近环境温度,按坏道处理
  361. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-02-23 22:00:00,2026-02-23 22:00:00,1,1,是,0.0,0.0,0.0,98.59,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  362. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-02-25 08:00:00,2026-02-25 10:00:00,3,2,是,0.0,0.0,0.0,102.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  363. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-04-12 15:00:00,2026-04-12 17:00:00,3,2,是,0.0,0.0,0.0,100.35,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  364. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-04-13 01:00:00,2026-04-13 03:00:00,3,2,是,0.0,0.0,0.0,97.19,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  365. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-04-20 07:00:00,2026-04-20 08:00:00,2,2,是,0.0,0.0,0.0,94.83,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  366. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-05-12 00:00:00,2026-05-12 01:00:00,2,2,是,0.0,0.0,0.0,98.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  367. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-05-15 07:00:00,2026-05-15 08:00:00,2,2,是,0.0,0.0,0.0,115.88,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  368. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-05-15 14:00:00,2026-05-15 15:00:00,2,2,是,0.0,0.0,0.0,122.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  369. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-05-17 14:00:00,2026-05-17 21:00:00,8,4,是,0.0,0.0,0.0,116.24,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  370. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-05-17 15:00:00,2026-05-17 17:00:00,3,2,是,0.0,0.0,0.0,101.38,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  371. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-05-20 12:00:00,2026-05-20 14:00:00,3,2,是,0.0,0.0,0.0,124.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  372. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-05-20 14:00:00,2026-05-20 15:00:00,2,2,是,0.0,0.0,0.0,107.61,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  373. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,停机/通道异常,2026-05-21 10:00:00,2026-05-21 11:00:00,2,2,是,0.0,0.0,0.0,104.95,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  374. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-05-21 19:00:00,2026-05-21 21:00:00,3,2,是,0.0,0.0,0.0,120.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  375. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-05-23 00:00:00,2026-05-23 01:00:00,2,2,是,0.0,0.0,0.0,118.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  376. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,停机/通道异常,2026-05-24 11:00:00,2026-05-24 12:00:00,2,2,是,0.0,0.0,0.0,102.24,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  377. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-05-25 04:00:00,2026-05-25 05:00:00,2,2,是,0.0,0.0,0.0,117.61,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  378. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-05-25 12:00:00,2026-05-25 14:00:00,3,2,是,0.0,0.0,0.0,102.75,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  379. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-05-25 19:00:00,2026-05-25 21:00:00,3,2,是,0.0,0.0,0.0,116.8,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  380. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-05-27 18:00:00,2026-05-27 19:00:00,2,2,是,0.0,0.0,0.0,122.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  381. 6号机,59,YSJ_18,一级1#缸排气温度,一级,1#,通道坏道,2026-05-30 07:00:00,2026-05-30 07:00:00,1,1,是,-0.0,-0.0,-0.0,96.22,单通道长期接近环境温度,按坏道处理
  382. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,通道坏道,2026-05-30 07:00:00,2026-05-30 07:00:00,1,1,是,-0.0,-0.0,-0.0,97.61,单通道长期接近环境温度,按坏道处理
  383. 6号机,59,YSJ_22,一级3#缸排气温度,一级,3#,通道坏道,2026-05-30 07:00:00,2026-05-30 07:00:00,1,1,是,-0.0,-0.0,-0.0,96.43,单通道长期接近环境温度,按坏道处理
  384. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,通道坏道,2026-05-30 07:00:00,2026-05-30 09:00:00,3,2,是,-0.0,-0.0,-0.0,110.26,单通道长期接近环境温度,按坏道处理
  385. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,通道坏道,2026-05-30 07:00:00,2026-05-30 09:00:00,3,2,是,-0.0,-0.0,-0.0,110.14,单通道长期接近环境温度,按坏道处理
  386. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,通道坏道,2026-05-30 07:00:00,2026-05-30 09:00:00,3,2,是,-0.0,-0.0,-0.0,109.71,单通道长期接近环境温度,按坏道处理
  387. 6号机,59,YSJ_19,二级2#缸排气温度,二级,2#,停机/通道异常,2026-06-22 11:00:00,2026-06-22 17:00:00,7,4,是,0.0,0.0,0.0,123.71,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  388. 6号机,59,YSJ_17,二级1#缸排气温度,二级,1#,停机/通道异常,2026-06-22 21:00:00,2026-06-22 22:00:00,2,2,是,0.0,0.0,0.0,120.17,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  389. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-06-23 00:00:00,2026-06-23 01:00:00,2,2,是,0.0,0.0,0.0,104.24,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  390. 6号机,59,YSJ_20,一级2#缸排气温度,一级,2#,停机/通道异常,2026-06-23 08:00:00,2026-06-23 10:00:00,3,2,是,0.0,0.0,0.0,107.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  391. 6号机,59,YSJ_21,二级3#缸排气温度,二级,3#,停机/通道异常,2026-06-25 08:00:00,2026-06-25 10:00:00,3,2,是,0.0,0.0,0.0,122.03,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  392. 7号机,47,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-01-01 14:00:00,2025-01-01 15:00:00,2,2,是,0.0,0.0,0.0,86.11,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  393. 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-01-01 18:00:00,2025-01-01 19:00:00,2,2,是,0.0,0.0,0.0,89.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  394. 7号机,47,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-01-02 10:00:00,2025-01-02 11:00:00,2,2,是,0.0,0.0,0.0,82.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  395. 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-01-05 10:00:00,2025-01-05 10:00:00,1,1,否,81.07,81.07,81.07,90.19,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  396. 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-01-05 10:00:00,2025-01-05 10:00:00,1,1,否,80.31,80.31,80.31,89.58,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  397. 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-01-06 01:00:00,2025-01-06 03:00:00,3,2,是,0.0,0.0,0.0,82.07,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  398. 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-01-06 01:00:00,2025-01-06 05:00:00,5,4,是,0.0,0.0,0.0,81.53,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  399. 7号机,47,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-01-06 12:00:00,2025-01-06 14:00:00,3,2,是,0.0,0.0,0.0,82.54,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  400. 7号机,47,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-01-09 18:00:00,2025-01-09 19:00:00,2,2,是,0.0,0.0,0.0,84.45,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  401. 7号机,47,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-01-24 10:00:00,2025-01-24 11:00:00,2,2,是,0.0,0.0,0.0,81.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  402. 7号机,47,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-01-25 11:00:00,2025-01-25 12:00:00,2,2,是,0.0,0.0,0.0,82.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  403. 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-01-26 05:00:00,2025-01-26 07:00:00,3,2,是,0.0,0.0,0.0,82.28,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  404. 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-01-26 15:00:00,2025-01-26 17:00:00,3,2,是,0.0,0.0,0.0,83.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  405. 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-01-27 21:00:00,2025-01-27 22:00:00,2,2,是,0.0,0.0,0.0,84.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  406. 7号机,47,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-01-28 21:00:00,2025-01-28 22:00:00,2,2,是,0.0,0.0,0.0,82.33,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  407. 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-01-29 05:00:00,2025-01-29 07:00:00,3,2,是,0.0,0.0,0.0,83.51,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  408. 7号机,47,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-01-29 14:00:00,2025-01-29 14:00:00,1,1,是,0.0,0.0,0.0,58.29,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  409. 7号机,47,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-01-30 11:00:00,2025-01-30 12:00:00,2,2,是,0.0,0.0,0.0,82.17,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  410. 7号机,47,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-02-01 04:00:00,2025-02-01 05:00:00,2,2,是,0.0,0.0,0.0,80.76,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  411. 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-02-01 12:00:00,2025-02-01 14:00:00,3,2,是,0.0,0.0,0.0,82.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  412. 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-02-01 18:00:00,2025-02-01 19:00:00,2,2,是,0.0,0.0,0.0,81.88,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  413. 7号机,47,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-02-03 08:00:00,2025-02-03 10:00:00,3,2,是,0.0,0.0,0.0,82.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  414. 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-02-03 11:00:00,2025-02-03 12:00:00,2,2,是,0.0,0.0,0.0,83.37,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  415. 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-02-05 04:00:00,2025-02-05 05:00:00,2,2,是,0.0,0.0,0.0,81.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  416. 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-02-07 00:00:00,2025-02-07 01:00:00,2,2,是,0.0,0.0,0.0,81.29,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  417. 7号机,47,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-02-07 12:00:00,2025-02-07 14:00:00,3,2,是,0.0,0.0,0.0,79.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  418. 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-02-10 17:00:00,2025-02-10 18:00:00,2,2,是,0.0,0.0,0.0,86.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  419. 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-02-11 04:00:00,2025-02-11 05:00:00,2,2,是,0.0,0.0,0.0,82.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  420. 7号机,47,YSJ_17,一级4列缸排气温度,一级,4列,通道坏道,2025-02-11 17:00:00,2025-02-11 17:00:00,1,1,是,0.0,0.0,0.0,82.26,单通道长期接近环境温度,按坏道处理
  421. 7号机,47,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-02-12 14:00:00,2025-02-12 15:00:00,2,2,是,0.0,0.0,0.0,58.35,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  422. 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-02-12 17:00:00,2025-02-12 18:00:00,2,2,是,0.0,0.0,0.0,82.1,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  423. 7号机,47,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-02-24 07:00:00,2025-02-24 08:00:00,2,2,是,0.0,0.0,0.0,81.33,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  424. 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-02-28 07:00:00,2025-02-28 08:00:00,2,2,是,0.0,0.0,0.0,81.65,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  425. 7号机,47,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-03-22 03:00:00,2025-03-22 04:00:00,2,2,是,0.0,0.0,0.0,83.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  426. 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-03-22 19:00:00,2025-03-22 21:00:00,3,2,是,0.0,0.0,0.0,94.18,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  427. 7号机,47,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-03-23 05:00:00,2025-03-23 07:00:00,3,2,是,0.0,0.0,0.0,87.09,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  428. 7号机,47,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-03-24 19:00:00,2025-03-24 21:00:00,3,2,是,0.0,0.0,0.0,88.21,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  429. 7号机,47,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-03-26 10:00:00,2025-03-26 11:00:00,2,2,是,0.0,0.0,0.0,89.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  430. 7号机,47,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-03-30 03:00:00,2025-03-30 04:00:00,2,2,是,0.0,0.0,0.0,81.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  431. 7号机,47,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-03-30 07:00:00,2025-03-30 08:00:00,2,2,是,0.0,0.0,0.0,83.1,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  432. 7号机,47,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-03-31 05:00:00,2025-03-31 07:00:00,3,2,是,0.0,0.0,0.0,83.03,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  433. 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-04-11 07:00:00,2025-04-11 08:00:00,2,2,是,0.0,0.0,0.0,93.4,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  434. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-04-14 01:00:00,2025-04-14 03:00:00,3,2,是,0.0,0.0,0.0,95.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  435. 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-04-15 01:00:00,2025-04-15 03:00:00,3,2,是,0.0,0.0,0.0,94.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  436. 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-04-15 15:00:00,2025-04-15 17:00:00,3,2,是,0.0,0.0,0.0,98.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  437. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-16 01:00:00,2025-04-16 03:00:00,3,2,是,0.0,0.0,0.0,95.19,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  438. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-04-16 01:00:00,2025-04-16 03:00:00,3,2,是,0.0,0.0,0.0,94.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  439. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-16 03:00:00,2025-04-16 04:00:00,2,2,是,0.0,0.0,0.0,94.38,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  440. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-16 14:00:00,2025-04-16 15:00:00,2,2,是,0.0,0.0,0.0,100.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  441. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-04-24 19:00:00,2025-04-24 21:00:00,3,2,是,0.0,0.0,0.0,93.17,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  442. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-26 10:00:00,2025-04-26 11:00:00,2,2,是,0.0,0.0,0.0,102.66,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  443. 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-04-26 19:00:00,2025-04-26 21:00:00,3,2,是,0.0,0.0,0.0,99.85,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  444. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-26 22:00:00,2025-04-26 22:00:00,1,1,是,0.0,0.0,0.0,97.46,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  445. 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-04-27 07:00:00,2025-04-27 08:00:00,2,2,是,0.0,0.0,0.0,66.83,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  446. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-30 01:00:00,2025-04-30 03:00:00,3,2,是,0.0,0.0,0.0,97.47,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  447. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-04-30 04:00:00,2025-04-30 05:00:00,2,2,是,0.0,0.0,0.0,95.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  448. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-05-06 07:00:00,2025-05-06 08:00:00,2,2,是,0.0,0.0,0.0,95.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  449. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-05-14 07:00:00,2025-05-14 18:00:00,12,6,是,0.0,0.0,0.0,101.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  450. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-05-16 06:00:00,2025-05-16 08:00:00,3,3,是,88.92,92.67,90.38,100.03,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  451. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-05-16 06:00:00,2025-05-16 08:00:00,3,3,是,88.76,92.54,90.24,99.88,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  452. 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,通道骤降,2025-05-16 07:00:00,2025-05-16 07:00:00,1,1,否,62.77,62.77,62.77,70.99,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  453. 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-05-16 14:00:00,2025-05-16 15:00:00,2,2,是,0.0,0.0,0.0,102.58,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  454. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,通道坏道,2025-05-17 17:00:00,2025-05-17 17:00:00,1,1,是,0.0,0.0,0.0,100.15,单通道长期接近环境温度,按坏道处理
  455. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-05-18 00:00:00,2025-05-18 01:00:00,2,2,是,0.0,0.0,0.0,90.89,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  456. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-05-20 05:00:00,2025-05-20 07:00:00,3,2,是,0.0,0.0,0.0,101.07,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  457. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-05-25 03:00:00,2025-05-25 04:00:00,2,2,是,0.0,0.0,0.0,88.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  458. 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-05-29 00:00:00,2025-05-29 01:00:00,2,2,是,0.0,0.0,0.0,62.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  459. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-05-29 18:00:00,2025-05-29 19:00:00,2,2,是,0.0,0.0,0.0,103.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  460. 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-06-01 10:00:00,2025-06-01 11:00:00,2,2,是,0.0,0.0,0.0,99.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  461. 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-06-01 12:00:00,2025-06-01 14:00:00,3,2,是,0.0,0.0,0.0,67.12,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  462. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-06-03 03:00:00,2025-06-03 04:00:00,2,2,是,0.0,0.0,0.0,94.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  463. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-06-03 08:00:00,2025-06-03 10:00:00,3,2,是,0.0,0.0,0.0,100.58,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  464. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-06-04 00:00:00,2025-06-04 01:00:00,2,2,是,0.0,0.0,0.0,99.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  465. 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-06-04 03:00:00,2025-06-04 04:00:00,2,2,是,0.0,0.0,0.0,68.47,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  466. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-06-04 04:00:00,2025-06-04 05:00:00,2,2,是,0.0,0.0,0.0,94.92,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  467. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-06-05 08:00:00,2025-06-05 08:00:00,1,1,否,98.32,98.32,98.32,107.48,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  468. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-06-05 08:00:00,2025-06-05 08:00:00,1,1,否,98.64,98.64,98.64,107.78,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  469. 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-06-05 12:00:00,2025-06-05 14:00:00,3,2,是,0.0,0.0,0.0,106.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  470. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-06-06 08:00:00,2025-06-06 15:00:00,8,3,是,0.0,99.05,0.0,110.03,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  471. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-06-06 08:00:00,2025-06-06 08:00:00,1,1,否,99.4,99.4,99.4,110.07,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  472. 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,通道骤降,2025-06-06 08:00:00,2025-06-06 08:00:00,1,1,否,71.95,71.95,71.95,81.09,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  473. 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-06-06 18:00:00,2025-06-06 19:00:00,2,2,是,0.0,0.0,0.0,78.62,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  474. 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-06-08 04:00:00,2025-06-08 05:00:00,2,2,是,0.0,0.0,0.0,108.58,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  475. 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-06-08 15:00:00,2025-06-08 17:00:00,3,2,是,0.0,0.0,0.0,109.24,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  476. 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-06-10 04:00:00,2025-06-10 05:00:00,2,2,是,0.0,0.0,0.0,106.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  477. 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-06-11 22:00:00,2025-06-11 22:00:00,1,1,是,0.0,0.0,0.0,78.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  478. 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-06-12 05:00:00,2025-06-12 07:00:00,3,2,是,0.0,0.0,0.0,110.83,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  479. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,通道坏道,2025-06-12 15:00:00,2025-06-12 15:00:00,1,1,是,0.0,0.0,0.0,109.87,单通道长期接近环境温度,按坏道处理
  480. 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-07-20 21:00:00,2025-07-20 22:00:00,2,2,是,0.0,0.0,0.0,69.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  481. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-07-22 07:00:00,2025-07-22 08:00:00,2,2,是,0.0,0.0,0.0,100.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  482. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-07-22 22:00:00,2025-07-22 22:00:00,1,1,是,0.0,0.0,0.0,101.18,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  483. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-07-24 22:00:00,2025-07-24 22:00:00,1,1,是,0.0,0.0,0.0,105.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  484. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-07-25 18:00:00,2025-07-25 19:00:00,2,2,是,0.0,0.0,0.0,107.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  485. 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-07-27 03:00:00,2025-07-27 04:00:00,2,2,是,0.0,0.0,0.0,104.53,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  486. 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-07-27 03:00:00,2025-07-27 04:00:00,2,2,是,0.0,0.0,0.0,73.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  487. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-07-27 10:00:00,2025-07-27 11:00:00,2,2,是,0.0,0.0,0.0,106.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  488. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-07-30 03:00:00,2025-07-30 04:00:00,2,2,是,0.0,0.0,0.0,101.27,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  489. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-07-30 18:00:00,2025-07-30 19:00:00,2,2,是,0.0,0.0,0.0,107.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  490. 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-08-01 00:00:00,2025-08-01 01:00:00,2,2,是,0.0,0.0,0.0,77.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  491. 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-08-07 17:00:00,2025-08-07 18:00:00,2,2,是,0.0,0.0,0.0,78.53,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  492. 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-08-08 12:00:00,2025-08-08 14:00:00,3,2,是,0.0,0.0,0.0,107.18,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  493. 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-08-27 11:00:00,2025-08-27 12:00:00,2,2,是,0.0,0.0,0.0,74.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  494. 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-08-28 00:00:00,2025-08-28 01:00:00,2,2,是,0.0,0.0,0.0,105.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  495. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-08-28 05:00:00,2025-08-28 07:00:00,3,2,是,0.0,0.0,0.0,98.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  496. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-08-28 19:00:00,2025-08-28 21:00:00,3,2,是,0.0,0.0,0.0,101.18,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  497. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-09-10 07:00:00,2025-09-10 08:00:00,2,2,是,0.0,0.0,0.0,102.75,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  498. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-09-20 01:00:00,2025-09-20 03:00:00,3,2,是,0.0,0.0,0.0,88.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  499. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-09-20 11:00:00,2025-09-20 12:00:00,2,2,是,0.0,0.0,0.0,94.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  500. 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-09-21 05:00:00,2025-09-21 07:00:00,3,2,是,0.0,0.0,0.0,100.65,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  501. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-09-22 11:00:00,2025-09-22 12:00:00,2,2,是,0.0,0.0,0.0,90.55,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  502. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-10-03 21:00:00,2025-10-03 22:00:00,2,2,是,0.0,0.0,0.0,91.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  503. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-10-04 19:00:00,2025-10-04 21:00:00,3,2,是,0.0,0.0,0.0,91.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  504. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-10-05 15:00:00,2025-10-05 17:00:00,3,2,是,0.0,0.0,0.0,101.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  505. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-10-06 01:00:00,2025-10-06 03:00:00,3,2,是,0.0,0.0,0.0,92.09,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  506. 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-10-06 12:00:00,2025-10-06 12:00:00,1,1,是,0.0,0.0,0.0,100.31,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  507. 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-11-16 05:00:00,2025-11-16 07:00:00,3,2,是,0.0,0.0,0.0,95.11,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  508. 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-11-19 14:00:00,2025-11-19 14:00:00,1,1,是,0.0,0.0,0.0,58.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  509. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-11-19 21:00:00,2025-11-19 22:00:00,2,2,是,0.0,0.0,0.0,80.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  510. 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-11-20 05:00:00,2025-11-20 07:00:00,3,2,是,0.0,0.0,0.0,93.73,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  511. 7号机,30,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-11-23 14:00:00,2025-11-23 15:00:00,2,2,是,0.0,0.0,0.0,59.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  512. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-11-27 10:00:00,2025-11-27 11:00:00,2,2,是,0.0,0.0,0.0,82.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  513. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-11-29 00:00:00,2025-11-29 01:00:00,2,2,是,0.0,0.0,0.0,80.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  514. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-11-29 21:00:00,2025-11-29 22:00:00,2,2,是,0.0,0.0,0.0,92.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  515. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-11-30 19:00:00,2025-11-30 21:00:00,3,2,是,0.0,0.0,0.0,82.94,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  516. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-12-01 07:00:00,2025-12-01 08:00:00,2,2,是,0.0,0.0,0.0,79.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  517. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-12-02 10:00:00,2025-12-02 11:00:00,2,2,是,0.0,0.0,0.0,83.04,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  518. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-12-05 00:00:00,2025-12-05 01:00:00,2,2,是,0.0,0.0,0.0,82.31,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  519. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-12-06 04:00:00,2025-12-06 05:00:00,2,2,是,0.0,0.0,0.0,90.75,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  520. 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-12-07 04:00:00,2025-12-07 05:00:00,2,2,是,0.0,0.0,0.0,94.17,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  521. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-01-12 03:00:00,2026-01-12 04:00:00,2,2,是,0.0,0.0,0.0,87.03,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  522. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-01-20 00:00:00,2026-01-20 01:00:00,2,2,是,0.0,0.0,0.0,82.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  523. 7号机,30,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-02-14 07:00:00,2026-02-14 08:00:00,2,2,是,0.0,0.0,0.0,90.1,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  524. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-03-13 12:00:00,2026-03-13 14:00:00,3,2,是,0.0,0.0,0.0,92.97,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  525. 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-13 22:00:00,2026-03-13 22:00:00,1,1,是,0.0,0.0,0.0,93.71,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  526. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-03-14 05:00:00,2026-03-14 07:00:00,3,2,是,0.0,0.0,0.0,98.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  527. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-03-20 07:00:00,2026-03-20 08:00:00,2,2,是,0.0,0.0,0.0,99.63,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  528. 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-21 10:00:00,2026-03-21 11:00:00,2,2,是,0.0,0.0,0.0,94.66,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  529. 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-22 04:00:00,2026-03-22 05:00:00,2,2,是,0.0,0.0,0.0,93.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  530. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-03-22 10:00:00,2026-03-22 11:00:00,2,2,是,0.0,0.0,0.0,93.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  531. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-03-23 11:00:00,2026-03-23 12:00:00,2,2,是,0.0,0.0,0.0,93.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  532. 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-27 18:00:00,2026-03-28 03:00:00,10,4,是,0.0,0.0,0.0,94.85,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  533. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-03-27 22:00:00,2026-03-27 22:00:00,1,1,是,0.0,0.0,0.0,93.33,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  534. 7号机,30,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-03-29 12:00:00,2026-03-29 14:00:00,3,2,是,0.0,0.0,0.0,94.18,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  535. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-04-01 10:00:00,2026-04-01 11:00:00,2,2,是,0.0,0.0,0.0,101.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  536. 7号机,30,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-04-02 00:00:00,2026-04-02 03:00:00,4,2,是,0.0,0.0,0.0,98.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  537. 7号机,30,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-04-02 07:00:00,2026-04-02 08:00:00,2,2,是,0.0,0.0,0.0,98.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  538. 7号机,30,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-04-02 11:00:00,2026-04-02 12:00:00,2,2,是,0.0,0.0,0.0,96.4,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  539. 7号机,50,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-05-08 07:00:00,2026-05-08 08:00:00,2,2,是,0.0,0.0,0.0,95.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  540. 7号机,50,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-05-11 18:00:00,2026-05-11 19:00:00,2,2,是,0.0,0.0,0.0,102.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  541. 7号机,50,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-05-12 04:00:00,2026-05-12 05:00:00,2,2,是,0.0,0.0,0.0,98.33,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  542. 7号机,50,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-05-12 22:00:00,2026-05-12 22:00:00,1,1,是,0.0,0.0,0.0,99.52,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  543. 7号机,50,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-05-16 10:00:00,2026-05-16 11:00:00,2,2,是,0.0,0.0,0.0,96.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  544. 7号机,50,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-05-17 07:00:00,2026-05-17 08:00:00,2,2,是,0.0,0.0,0.0,62.11,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  545. 7号机,50,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-05-18 22:00:00,2026-05-18 22:00:00,1,1,是,0.0,0.0,0.0,98.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  546. 7号机,50,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-05-19 08:00:00,2026-05-19 10:00:00,3,2,是,0.0,0.0,0.0,100.27,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  547. 7号机,50,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-05-20 04:00:00,2026-05-20 05:00:00,2,2,是,0.0,0.0,0.0,96.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  548. 7号机,50,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-06-02 05:00:00,2026-06-02 07:00:00,3,2,是,0.0,0.0,0.0,98.25,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  549. 7号机,50,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-06-03 17:00:00,2026-06-03 18:00:00,2,2,是,0.0,0.0,0.0,108.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  550. 7号机,50,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-04 10:00:00,2026-06-04 11:00:00,2,2,是,0.0,0.0,0.0,101.45,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  551. 7号机,50,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-06-05 08:00:00,2026-06-05 10:00:00,3,2,是,0.0,0.0,0.0,103.63,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  552. 7号机,50,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-06-05 10:00:00,2026-06-05 11:00:00,2,2,是,0.0,0.0,0.0,101.65,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  553. 7号机,50,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-06-05 14:00:00,2026-06-05 15:00:00,2,2,是,0.0,0.0,0.0,103.43,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  554. 7号机,50,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-28 17:00:00,2026-06-28 18:00:00,2,2,是,0.0,0.0,0.0,102.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  555. 7号机,50,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-29 18:00:00,2026-06-29 19:00:00,2,2,是,0.0,0.0,0.0,100.32,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  556. 7号机,50,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-06-30 12:00:00,2026-06-30 14:00:00,3,2,是,0.0,0.0,0.0,71.43,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  557. 7号机,50,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-30 17:00:00,2026-06-30 18:00:00,2,2,是,0.0,0.0,0.0,102.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  558. 7号机,50,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-07-13 15:00:00,2026-07-13 17:00:00,3,2,是,0.0,0.0,0.0,106.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  559. 7号机,50,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-07-13 19:00:00,2026-07-13 21:00:00,3,2,是,0.0,0.0,0.0,104.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  560. 7号机,50,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-07-15 12:00:00,2026-07-15 14:00:00,3,2,是,0.0,0.0,0.0,70.99,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  561. 7号机,50,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-07-16 03:00:00,2026-07-16 04:00:00,2,2,是,0.0,0.0,0.0,103.15,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  562. 7号机,50,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-07-17 03:00:00,2026-07-17 04:00:00,2,2,是,0.0,0.0,0.0,66.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  563. 7号机,50,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-07-19 00:00:00,2026-07-19 01:00:00,2,2,是,0.0,0.0,0.0,71.17,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  564. 7号机,50,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-07-20 07:00:00,2026-07-20 08:00:00,2,2,是,0.0,0.0,0.0,104.76,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  565. 7号机,50,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-07-20 07:00:00,2026-07-20 08:00:00,2,2,是,0.0,0.0,0.0,103.88,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  566. 7号机,50,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-07-27 21:00:00,2026-07-27 22:00:00,2,2,是,0.0,0.0,0.0,102.97,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  567. 8号机,48,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-01-01 03:00:00,2025-01-01 03:00:00,1,1,是,0.0,0.0,0.0,89.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  568. 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-01-02 04:00:00,2025-01-02 05:00:00,2,2,是,0.0,0.0,0.0,82.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  569. 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-01-02 17:00:00,2025-01-02 18:00:00,2,2,是,0.0,0.0,0.0,83.11,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  570. 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,通道坏道,2025-01-09 07:00:00,2025-01-09 07:00:00,1,1,是,0.0,0.0,0.0,80.46,单通道长期接近环境温度,按坏道处理
  571. 8号机,48,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-01-18 12:00:00,2025-01-18 14:00:00,3,2,是,0.0,0.0,0.0,84.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  572. 8号机,48,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-01-24 10:00:00,2025-01-24 11:00:00,2,2,是,0.0,0.0,0.0,78.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  573. 8号机,48,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-01-27 03:00:00,2025-01-27 04:00:00,2,2,是,0.0,0.0,0.0,78.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  574. 8号机,48,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-01-27 19:00:00,2025-01-27 21:00:00,3,2,是,0.0,0.0,0.0,76.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  575. 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-01-28 18:00:00,2025-01-28 19:00:00,2,2,是,0.0,0.0,0.0,80.8,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  576. 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-01-29 19:00:00,2025-01-29 21:00:00,3,2,是,0.0,0.0,0.0,81.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  577. 8号机,48,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-01-29 22:00:00,2025-01-29 22:00:00,1,1,是,0.0,0.0,0.0,82.55,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  578. 8号机,48,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-02-02 12:00:00,2025-02-02 14:00:00,3,2,是,0.0,0.0,0.0,81.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  579. 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-02-08 03:00:00,2025-02-08 04:00:00,2,2,是,0.0,0.0,0.0,78.86,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  580. 8号机,48,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-02-10 11:00:00,2025-02-10 12:00:00,2,2,是,0.0,0.0,0.0,81.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  581. 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-02-10 17:00:00,2025-02-10 18:00:00,2,2,是,0.0,0.0,0.0,82.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  582. 8号机,48,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-02-11 22:00:00,2025-02-11 22:00:00,1,1,是,0.0,0.0,0.0,79.32,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  583. 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-02-13 00:00:00,2025-02-13 01:00:00,2,2,是,0.0,0.0,0.0,79.51,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  584. 8号机,48,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-02-13 08:00:00,2025-02-13 10:00:00,3,2,是,0.0,0.0,0.0,79.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  585. 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-02-13 11:00:00,2025-02-13 12:00:00,2,2,是,0.0,0.0,0.0,81.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  586. 8号机,48,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-03-13 14:00:00,2025-03-13 15:00:00,2,2,是,0.0,0.0,0.0,87.11,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  587. 8号机,48,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-03-14 03:00:00,2025-03-14 04:00:00,2,2,是,0.0,0.0,0.0,84.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  588. 8号机,48,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-03-15 22:00:00,2025-03-15 22:00:00,1,1,是,0.0,0.0,0.0,82.47,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  589. 8号机,48,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-03-23 18:00:00,2025-03-23 19:00:00,2,2,是,0.0,0.0,0.0,95.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  590. 8号机,48,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-03-24 01:00:00,2025-03-24 03:00:00,3,2,是,0.0,0.0,0.0,89.04,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  591. 8号机,48,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-03-26 12:00:00,2025-03-26 14:00:00,3,2,是,0.0,0.0,0.0,101.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  592. 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-01 18:00:00,2025-04-01 19:00:00,2,2,是,0.0,0.0,0.0,95.47,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  593. 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-02 11:00:00,2025-04-02 12:00:00,2,2,是,0.0,0.0,0.0,94.69,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  594. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-02 14:00:00,2025-04-02 15:00:00,2,2,是,0.0,0.0,0.0,91.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  595. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-06 07:00:00,2025-04-06 08:00:00,2,2,是,0.0,0.0,0.0,85.73,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  596. 8号机,31,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-04-06 10:00:00,2025-04-06 10:00:00,1,1,是,0.0,0.0,0.0,63.94,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  597. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-07 07:00:00,2025-04-07 08:00:00,2,2,是,0.0,0.0,0.0,85.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  598. 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-21 04:00:00,2025-04-21 05:00:00,2,2,是,0.0,0.0,0.0,96.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  599. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-21 08:00:00,2025-04-21 10:00:00,3,2,是,0.0,0.0,0.0,93.38,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  600. 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,通道坏道,2025-04-22 14:00:00,2025-04-22 14:00:00,1,1,是,0.0,0.0,0.0,97.82,单通道长期接近环境温度,按坏道处理
  601. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-04-23 05:00:00,2025-04-23 07:00:00,3,2,是,0.0,0.0,0.0,88.15,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  602. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-04-25 07:00:00,2025-04-25 08:00:00,2,2,是,80.99,83.67,82.33,91.72,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  603. 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-04-25 07:00:00,2025-04-25 08:00:00,2,2,是,80.2,82.87,81.54,90.79,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  604. 8号机,31,YSJ_21,三级1列缸排气温度,三级,1列,通道骤降,2025-04-25 07:00:00,2025-04-25 07:00:00,1,1,否,57.32,57.32,57.32,65.84,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  605. 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-28 07:00:00,2025-04-28 08:00:00,2,2,是,0.0,0.0,0.0,95.18,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  606. 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-04-30 05:00:00,2025-04-30 07:00:00,3,2,是,0.0,0.0,0.0,89.35,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  607. 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-05-01 03:00:00,2025-05-01 04:00:00,2,2,是,0.0,0.0,0.0,94.87,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  608. 8号机,31,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-05-01 22:00:00,2025-05-01 22:00:00,1,1,是,0.0,0.0,0.0,98.95,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  609. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-05-02 21:00:00,2025-05-02 22:00:00,2,2,是,0.0,0.0,0.0,92.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  610. 8号机,31,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-05-05 00:00:00,2025-05-05 01:00:00,2,2,是,0.0,0.0,0.0,96.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  611. 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-05-26 07:00:00,2025-05-26 12:00:00,6,4,是,0.0,0.0,0.0,98.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  612. 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-05-28 03:00:00,2025-05-28 04:00:00,2,2,是,0.0,0.0,0.0,96.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  613. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-05-28 03:00:00,2025-05-28 04:00:00,2,2,是,0.0,0.0,0.0,90.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  614. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-06-19 10:00:00,2025-06-19 11:00:00,2,2,是,0.0,0.0,0.0,99.87,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  615. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-06-20 00:00:00,2025-06-20 01:00:00,2,2,是,0.0,0.0,0.0,95.01,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  616. 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-06-20 03:00:00,2025-06-20 04:00:00,2,2,是,0.0,0.0,0.0,100.46,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  617. 8号机,31,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-06-21 15:00:00,2025-06-21 17:00:00,3,2,是,0.0,0.0,0.0,106.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  618. 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-06-23 11:00:00,2025-06-23 12:00:00,2,2,是,0.0,0.0,0.0,105.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  619. 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-06-23 22:00:00,2025-06-23 22:00:00,1,1,是,0.0,0.0,0.0,98.33,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  620. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-06-24 22:00:00,2025-06-24 22:00:00,1,1,是,0.0,0.0,0.0,99.61,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  621. 8号机,31,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-06-25 08:00:00,2025-06-25 10:00:00,3,2,是,0.0,0.0,0.0,102.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  622. 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-06-25 21:00:00,2025-06-25 22:00:00,2,2,是,0.0,0.0,0.0,95.16,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  623. 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-06-27 21:00:00,2025-06-27 22:00:00,2,2,是,0.0,0.0,0.0,102.03,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  624. 8号机,31,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-06-28 00:00:00,2025-06-28 01:00:00,2,2,是,0.0,0.0,0.0,68.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  625. 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-06-28 07:00:00,2025-06-28 08:00:00,2,2,是,0.0,0.0,0.0,97.41,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  626. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-06-28 18:00:00,2025-06-28 19:00:00,2,2,是,0.0,0.0,0.0,103.95,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  627. 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-06-29 19:00:00,2025-06-29 21:00:00,3,2,是,0.0,0.0,0.0,102.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  628. 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-06-30 03:00:00,2025-06-30 04:00:00,2,2,是,0.0,0.0,0.0,96.17,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  629. 8号机,31,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-07-01 01:00:00,2025-07-01 03:00:00,3,2,是,0.0,0.0,0.0,102.29,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  630. 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,通道坏道,2025-07-02 08:00:00,2025-07-02 08:00:00,1,1,是,0.0,0.0,0.0,101.87,单通道长期接近环境温度,按坏道处理
  631. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-07-08 05:00:00,2025-07-08 07:00:00,3,2,是,0.0,0.0,0.0,98.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  632. 8号机,31,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-07-08 21:00:00,2025-07-08 22:00:00,2,2,是,0.0,0.0,0.0,104.53,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  633. 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-07-09 01:00:00,2025-07-09 03:00:00,3,2,是,0.0,0.0,0.0,97.66,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  634. 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-09-26 03:00:00,2025-09-26 04:00:00,2,2,是,0.0,0.0,0.0,89.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  635. 8号机,31,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-09-29 08:00:00,2025-09-29 10:00:00,3,2,是,0.0,0.0,0.0,66.85,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  636. 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-09-30 00:00:00,2025-09-30 01:00:00,2,2,是,0.0,0.0,0.0,98.97,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  637. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-09-30 12:00:00,2025-09-30 14:00:00,3,2,是,0.0,0.0,0.0,100.21,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  638. 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-10-01 08:00:00,2025-10-01 10:00:00,3,2,是,0.0,0.0,0.0,98.7,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  639. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-10-01 10:00:00,2025-10-01 11:00:00,2,2,是,0.0,0.0,0.0,91.08,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  640. 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-10-01 12:00:00,2025-10-01 14:00:00,3,2,是,0.0,0.0,0.0,99.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  641. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-10-23 01:00:00,2025-10-23 03:00:00,3,2,是,0.0,0.0,0.0,83.44,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  642. 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-12-16 12:00:00,2025-12-16 14:00:00,3,2,是,0.0,0.0,0.0,91.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  643. 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-12-20 00:00:00,2025-12-20 01:00:00,2,2,是,0.0,0.0,0.0,90.87,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  644. 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-12-20 18:00:00,2025-12-20 19:00:00,2,2,是,0.0,0.0,0.0,90.33,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  645. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-12-21 04:00:00,2025-12-21 05:00:00,2,2,是,0.0,0.0,0.0,77.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  646. 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-12-31 19:00:00,2025-12-31 21:00:00,3,2,是,0.0,0.0,0.0,77.65,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  647. 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-01-11 00:00:00,2026-01-11 01:00:00,2,2,是,0.0,0.0,0.0,77.51,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  648. 8号机,31,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-01-11 22:00:00,2026-01-11 22:00:00,1,1,是,0.0,0.0,0.0,89.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  649. 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-03-15 19:00:00,2026-03-15 21:00:00,3,2,是,0.0,0.0,0.0,83.8,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  650. 8号机,31,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-03-17 01:00:00,2026-03-17 03:00:00,3,2,是,0.0,0.0,0.0,89.84,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  651. 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-03-17 17:00:00,2026-03-17 18:00:00,2,2,是,0.0,0.0,0.0,87.5,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  652. 8号机,31,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-03-18 00:00:00,2026-03-18 01:00:00,2,2,是,0.0,0.0,0.0,88.29,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  653. 8号机,31,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-03-21 04:00:00,2026-03-21 05:00:00,2,2,是,0.0,0.0,0.0,64.59,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  654. 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-03-21 21:00:00,2026-03-21 22:00:00,2,2,是,0.0,0.0,0.0,87.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  655. 8号机,31,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-04-25 21:00:00,2026-04-25 22:00:00,2,2,是,0.0,0.0,0.0,93.95,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  656. 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-04-30 07:00:00,2026-04-30 08:00:00,2,2,是,0.0,0.0,0.0,86.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  657. 8号机,31,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-05-01 21:00:00,2026-05-01 22:00:00,2,2,是,0.0,0.0,0.0,86.32,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  658. 8号机,51,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-05-02 14:00:00,2026-05-02 15:00:00,2,2,是,0.0,0.0,0.0,91.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  659. 8号机,51,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-05-04 17:00:00,2026-05-04 18:00:00,2,2,是,0.0,0.0,0.0,94.94,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  660. 8号机,51,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-05-06 04:00:00,2026-05-06 05:00:00,2,2,是,0.0,0.0,0.0,89.21,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  661. 8号机,51,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-05-31 01:00:00,2026-05-31 03:00:00,3,2,是,0.0,0.0,0.0,98.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  662. 8号机,51,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-05-31 08:00:00,2026-05-31 10:00:00,3,2,是,0.0,0.0,0.0,94.17,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  663. 8号机,51,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-05-31 18:00:00,2026-05-31 19:00:00,2,2,是,0.0,0.0,0.0,98.39,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  664. 8号机,51,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-06-01 07:00:00,2026-06-01 08:00:00,2,2,是,0.0,0.0,0.0,99.84,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  665. 8号机,51,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-06-07 03:00:00,2026-06-07 04:00:00,2,2,是,0.0,0.0,0.0,92.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  666. 8号机,51,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-07 10:00:00,2026-06-07 11:00:00,2,2,是,0.0,0.0,0.0,98.99,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  667. 8号机,51,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-07 18:00:00,2026-06-07 19:00:00,2,2,是,0.0,0.0,0.0,98.27,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  668. 8号机,51,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-06-09 05:00:00,2026-06-09 07:00:00,3,2,是,0.0,0.0,0.0,98.69,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  669. 8号机,51,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-06-11 03:00:00,2026-06-11 04:00:00,2,2,是,0.0,0.0,0.0,98.81,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  670. 8号机,51,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-06-13 05:00:00,2026-06-13 07:00:00,3,2,是,0.0,0.0,0.0,100.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  671. 8号机,51,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-14 07:00:00,2026-06-14 08:00:00,2,2,是,0.0,0.0,0.0,98.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  672. 8号机,51,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-06-14 15:00:00,2026-06-14 17:00:00,3,2,是,0.0,0.0,0.0,102.41,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  673. 8号机,51,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-14 17:00:00,2026-06-15 01:00:00,9,4,是,0.0,0.0,0.0,100.07,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  674. 8号机,51,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-06-16 03:00:00,2026-06-16 04:00:00,2,2,是,0.0,0.0,0.0,67.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  675. 8号机,51,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-06-17 04:00:00,2026-06-17 05:00:00,2,2,是,0.0,0.0,0.0,98.88,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  676. 8号机,51,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-06-17 17:00:00,2026-06-17 18:00:00,2,2,是,0.0,0.0,0.0,101.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  677. 8号机,51,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-07-20 21:00:00,2026-07-21 10:00:00,14,6,是,0.0,0.0,0.0,105.05,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  678. 8号机,51,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-07-22 12:00:00,2026-07-22 14:00:00,3,2,是,0.0,0.0,0.0,104.69,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  679. 8号机,51,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-07-22 15:00:00,2026-07-22 17:00:00,3,2,是,0.0,0.0,0.0,69.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  680. 8号机,51,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-07-26 05:00:00,2026-07-26 07:00:00,3,2,是,0.0,0.0,0.0,100.1,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  681. 8号机,51,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-07-27 00:00:00,2026-07-27 01:00:00,2,2,是,0.0,0.0,0.0,102.45,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  682. 8号机,51,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-07-28 19:00:00,2026-07-28 21:00:00,3,2,是,0.0,0.0,0.0,100.62,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  683. 8号机,51,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-07-29 03:00:00,2026-07-29 04:00:00,2,2,是,0.0,0.0,0.0,103.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  684. 8号机,51,YSJ_19,二级3列缸排气温度,二级,3列,通道坏道,2026-07-29 21:00:00,2026-07-29 21:00:00,1,1,是,0.0,0.0,0.0,101.51,单通道长期接近环境温度,按坏道处理
  685. 8号机,51,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-07-30 03:00:00,2026-07-30 04:00:00,2,2,是,0.0,0.0,0.0,67.21,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  686. 9号机,49,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-01-11 03:00:00,2025-01-11 04:00:00,2,2,是,0.0,0.0,0.0,76.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  687. 9号机,49,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-01-13 10:00:00,2025-01-13 11:00:00,2,2,是,0.0,0.0,0.0,77.46,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  688. 9号机,49,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-01-13 19:00:00,2025-01-13 21:00:00,3,2,是,0.0,0.0,0.0,79.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  689. 9号机,49,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-01-14 17:00:00,2025-01-14 18:00:00,2,2,是,0.0,0.0,0.0,81.73,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  690. 9号机,49,YSJ_18,一级6列缸排气温度,一级,6列,通道骤降,2025-03-07 11:00:00,2025-03-07 11:00:00,1,1,否,54.93,54.93,54.93,80.8,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  691. 9号机,49,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-03-07 11:00:00,2025-03-07 12:00:00,2,2,是,48.6,59.89,54.25,78.77,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  692. 9号机,49,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-03-07 11:00:00,2025-03-07 12:00:00,2,2,是,46.97,58.73,52.85,77.69,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  693. 9号机,49,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-03-12 14:00:00,2025-03-12 14:00:00,1,1,否,54.41,54.41,54.41,85.32,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  694. 9号机,49,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-03-12 14:00:00,2025-03-12 14:00:00,1,1,否,51.74,51.74,51.74,84.57,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  695. 9号机,49,YSJ_21,三级1列缸排气温度,三级,1列,通道骤降,2025-03-12 14:00:00,2025-03-12 14:00:00,1,1,否,52.21,52.21,52.21,60.34,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  696. 9号机,49,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-03-13 03:00:00,2025-03-13 04:00:00,2,2,是,0.0,0.0,0.0,79.23,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  697. 9号机,49,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-03-14 07:00:00,2025-03-14 08:00:00,2,2,是,0.0,0.0,0.0,78.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  698. 9号机,49,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-03-27 05:00:00,2025-03-27 07:00:00,3,2,是,0.0,0.0,0.0,85.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  699. 9号机,49,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-03-28 00:00:00,2025-03-28 01:00:00,2,2,是,0.0,0.0,0.0,83.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  700. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-04-10 01:00:00,2025-04-10 03:00:00,3,2,是,0.0,0.0,0.0,84.73,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  701. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-04-18 03:00:00,2025-04-18 04:00:00,2,2,是,0.0,0.0,0.0,89.8,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  702. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-04-20 22:00:00,2025-04-20 22:00:00,1,1,是,0.0,0.0,0.0,90.81,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  703. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-04-22 10:00:00,2025-04-22 11:00:00,2,2,是,0.0,0.0,0.0,70.75,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  704. 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-04-23 06:00:00,2025-04-23 09:00:00,4,4,是,83.03,91.01,84.16,96.93,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  705. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-04-23 06:00:00,2025-04-23 09:00:00,4,4,是,82.03,90.1,83.19,95.99,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  706. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,通道骤降,2025-04-23 06:00:00,2025-04-23 08:00:00,3,3,是,62.93,64.3,63.59,74.65,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  707. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-05-12 21:00:00,2025-05-12 22:00:00,2,2,是,0.0,0.0,0.0,98.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  708. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-05-13 18:00:00,2025-05-13 19:00:00,2,2,是,0.0,0.0,0.0,98.93,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  709. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-05-14 10:00:00,2025-05-14 11:00:00,2,2,是,0.0,0.0,0.0,100.09,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  710. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-05-15 21:00:00,2025-05-15 22:00:00,2,2,是,0.0,0.0,0.0,98.97,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  711. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-05-16 17:00:00,2025-05-16 18:00:00,2,2,是,0.0,0.0,0.0,71.31,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  712. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-05-17 08:00:00,2025-05-17 10:00:00,3,2,是,0.0,0.0,0.0,68.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  713. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-05-17 19:00:00,2025-05-17 21:00:00,3,2,是,0.0,0.0,0.0,97.09,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  714. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-05-19 15:00:00,2025-05-19 17:00:00,3,2,是,0.0,0.0,0.0,104.0,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  715. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-05-22 22:00:00,2025-05-22 22:00:00,1,1,是,0.0,0.0,0.0,96.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  716. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-05-26 05:00:00,2025-05-26 07:00:00,3,2,是,0.0,0.0,0.0,97.56,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  717. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-05-27 00:00:00,2025-05-27 01:00:00,2,2,是,0.0,0.0,0.0,97.73,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  718. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-05-27 18:00:00,2025-05-27 19:00:00,2,2,是,0.0,0.0,0.0,95.39,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  719. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-05-28 15:00:00,2025-05-28 17:00:00,3,2,是,0.0,0.0,0.0,102.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  720. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-06-01 14:00:00,2025-06-01 15:00:00,2,2,是,0.0,0.0,0.0,100.39,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  721. 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-06-03 07:00:00,2025-06-03 08:00:00,2,2,是,0.0,0.0,0.0,90.67,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  722. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-06-07 00:00:00,2025-06-07 01:00:00,2,2,是,0.0,0.0,0.0,101.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  723. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-06-07 11:00:00,2025-06-07 12:00:00,2,2,是,0.0,0.0,0.0,73.37,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  724. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-06-07 21:00:00,2025-06-07 22:00:00,2,2,是,0.0,0.0,0.0,103.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  725. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-06-09 01:00:00,2025-06-09 03:00:00,3,2,是,0.0,0.0,0.0,100.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  726. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-06-09 18:00:00,2025-06-09 19:00:00,2,2,是,0.0,0.0,0.0,101.21,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  727. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-06-11 01:00:00,2025-06-11 03:00:00,3,2,是,0.0,0.0,0.0,103.43,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  728. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-06-13 03:00:00,2025-06-13 04:00:00,2,2,是,0.0,0.0,0.0,104.39,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  729. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-06-13 14:00:00,2025-06-13 15:00:00,2,2,是,0.0,0.0,0.0,76.25,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  730. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-06-17 21:00:00,2025-06-17 22:00:00,2,2,是,0.0,0.0,0.0,104.81,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  731. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-06-18 07:00:00,2025-06-18 08:00:00,2,2,是,0.0,0.0,0.0,97.2,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  732. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-07-02 19:00:00,2025-07-02 21:00:00,3,2,是,0.0,0.0,0.0,106.38,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  733. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-07-18 14:00:00,2025-07-18 15:00:00,2,2,是,0.0,0.0,0.0,76.63,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  734. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-07-21 07:00:00,2025-07-21 14:00:00,8,4,是,0.0,0.0,0.0,105.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  735. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-07-21 08:00:00,2025-07-21 10:00:00,3,2,是,0.0,0.0,0.0,106.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  736. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-07-21 12:00:00,2025-07-21 14:00:00,3,2,是,0.0,0.0,0.0,99.4,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  737. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-07-22 05:00:00,2025-07-22 07:00:00,3,2,是,0.0,0.0,0.0,105.95,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  738. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-07-23 17:00:00,2025-07-23 18:00:00,2,2,是,0.0,0.0,0.0,106.28,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  739. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-07-24 04:00:00,2025-07-24 05:00:00,2,2,是,0.0,0.0,0.0,96.19,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  740. 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-07-24 15:00:00,2025-07-24 17:00:00,3,2,是,0.0,0.0,0.0,102.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  741. 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-08-09 18:00:00,2025-08-09 19:00:00,2,2,是,0.0,0.0,0.0,99.45,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  742. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-08-10 00:00:00,2025-08-10 01:00:00,2,2,是,0.0,0.0,0.0,104.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  743. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-08-16 22:00:00,2025-08-16 22:00:00,1,1,是,0.0,0.0,0.0,105.79,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  744. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-08-17 14:00:00,2025-08-17 15:00:00,2,2,是,0.0,0.0,0.0,110.4,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  745. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-08-18 01:00:00,2025-08-18 03:00:00,3,2,是,0.0,0.0,0.0,96.58,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  746. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-08-18 19:00:00,2025-08-18 21:00:00,3,2,是,0.0,0.0,0.0,107.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  747. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-08-20 07:00:00,2025-08-20 14:00:00,8,4,是,0.0,0.0,0.0,100.43,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  748. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-08-21 10:00:00,2025-08-21 11:00:00,2,2,是,0.0,0.0,0.0,72.14,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  749. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-08-24 01:00:00,2025-08-24 03:00:00,3,2,是,0.0,0.0,0.0,67.96,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  750. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-08-30 07:00:00,2025-08-30 08:00:00,2,2,是,0.0,0.0,0.0,102.65,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  751. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-08-30 12:00:00,2025-08-30 14:00:00,3,2,是,0.0,0.0,0.0,105.55,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  752. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-08-31 19:00:00,2025-08-31 21:00:00,3,2,是,0.0,0.0,0.0,96.15,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  753. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-08-31 19:00:00,2025-08-31 21:00:00,3,2,是,0.0,0.0,0.0,69.82,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  754. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-09-01 04:00:00,2025-09-01 05:00:00,2,2,是,0.0,0.0,0.0,102.2,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  755. 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-09-01 04:00:00,2025-09-01 05:00:00,2,2,是,0.0,0.0,0.0,92.66,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  756. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-09-06 04:00:00,2025-09-06 05:00:00,2,2,是,0.0,0.0,0.0,65.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  757. 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-09-07 07:00:00,2025-09-07 08:00:00,2,2,是,0.0,0.0,0.0,90.89,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  758. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-09-23 21:00:00,2025-09-23 22:00:00,2,2,是,0.0,0.0,0.0,66.13,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  759. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-10-02 14:00:00,2025-10-02 15:00:00,2,2,是,0.0,0.0,0.0,101.81,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  760. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-10-03 14:00:00,2025-10-03 15:00:00,2,2,是,0.0,0.0,0.0,100.62,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  761. 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-10-04 00:00:00,2025-10-04 01:00:00,2,2,是,0.0,0.0,0.0,89.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  762. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-10-06 05:00:00,2025-10-06 07:00:00,3,2,是,0.0,0.0,0.0,99.24,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  763. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-10-07 10:00:00,2025-10-07 11:00:00,2,2,是,0.0,0.0,0.0,69.12,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  764. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-10-10 11:00:00,2025-10-10 12:00:00,2,2,是,0.0,0.0,0.0,85.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  765. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-10-11 07:00:00,2025-10-11 08:00:00,2,2,是,0.0,0.0,0.0,100.09,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  766. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2025-10-12 15:00:00,2025-10-12 17:00:00,3,2,是,0.0,0.0,0.0,65.78,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  767. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-10-18 00:00:00,2025-10-18 01:00:00,2,2,是,0.0,0.0,0.0,98.25,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  768. 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2025-10-18 05:00:00,2025-10-18 07:00:00,3,2,是,0.0,0.0,0.0,84.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  769. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-10-19 10:00:00,2025-10-19 11:00:00,2,2,是,0.0,0.0,0.0,98.94,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  770. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-10-20 07:00:00,2025-10-20 08:00:00,2,2,是,0.0,0.0,0.0,97.36,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  771. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-10-20 15:00:00,2025-10-20 17:00:00,3,2,是,0.0,0.0,0.0,94.89,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  772. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2025-10-21 08:00:00,2025-10-21 10:00:00,3,2,是,0.0,0.0,0.0,97.91,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  773. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2025-10-21 19:00:00,2025-10-21 21:00:00,3,2,是,0.0,0.0,0.0,96.74,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  774. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2025-11-02 03:00:00,2025-11-02 04:00:00,2,2,是,0.0,0.0,0.0,94.12,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  775. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2025-11-06 17:00:00,2025-11-06 18:00:00,2,2,是,0.0,0.0,0.0,82.02,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  776. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,通道坏道,2025-11-08 00:00:00,2025-11-08 00:00:00,1,1,是,0.0,0.0,0.0,59.96,单通道长期接近环境温度,按坏道处理
  777. 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-11-12 09:00:00,2025-11-12 09:00:00,1,1,否,79.35,79.35,79.35,87.67,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  778. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-11-12 09:00:00,2025-11-12 09:00:00,1,1,否,78.43,78.43,78.43,86.72,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  779. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,通道骤降,2025-11-12 09:00:00,2025-11-12 09:00:00,1,1,否,67.46,67.46,67.46,76.32,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  780. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,通道骤降,2025-11-14 16:00:00,2025-11-14 16:00:00,1,1,否,-0.0,-0.0,-0.0,98.74,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  781. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,通道骤降,2025-11-14 16:00:00,2025-11-14 16:00:00,1,1,否,-0.0,-0.0,-0.0,97.73,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  782. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,通道骤降,2025-11-14 16:00:00,2025-11-14 16:00:00,1,1,否,-0.0,-0.0,-0.0,96.49,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  783. 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2025-11-14 16:00:00,2025-11-14 16:00:00,1,1,否,-0.0,-0.0,-0.0,86.19,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  784. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2025-11-14 16:00:00,2025-11-14 16:00:00,1,1,否,-0.0,-0.0,-0.0,85.29,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  785. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,通道骤降,2025-11-14 16:00:00,2025-11-14 16:00:00,1,1,否,-0.0,-0.0,-0.0,69.98,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  786. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-01-22 10:00:00,2026-01-22 11:00:00,2,2,是,0.0,0.0,0.0,82.83,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  787. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-01-24 14:00:00,2026-01-24 15:00:00,2,2,是,0.0,0.0,0.0,92.57,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  788. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-01-25 22:00:00,2026-01-25 22:00:00,1,1,是,0.0,0.0,0.0,89.45,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  789. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-01-29 05:00:00,2026-01-29 07:00:00,3,2,是,0.0,0.0,0.0,65.26,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  790. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-01-31 08:00:00,2026-01-31 10:00:00,3,2,是,0.0,0.0,0.0,91.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  791. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-02-01 05:00:00,2026-02-01 07:00:00,3,2,是,0.0,0.0,0.0,64.83,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  792. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-02-01 15:00:00,2026-02-01 17:00:00,3,2,是,0.0,0.0,0.0,91.85,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  793. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-02-04 01:00:00,2026-02-04 03:00:00,3,2,是,0.0,0.0,0.0,61.48,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  794. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-02-04 04:00:00,2026-02-04 05:00:00,2,2,是,0.0,0.0,0.0,89.77,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  795. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-02-04 19:00:00,2026-02-04 22:00:00,4,2,是,0.0,0.0,0.0,93.41,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  796. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-02-06 14:00:00,2026-02-06 15:00:00,2,2,是,0.0,0.0,0.0,92.3,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  797. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-03 19:00:00,2026-03-03 21:00:00,3,2,是,0.0,0.0,0.0,94.06,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  798. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-06 00:00:00,2026-03-06 01:00:00,2,2,是,0.0,0.0,0.0,92.74,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  799. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-03-06 05:00:00,2026-03-06 07:00:00,3,2,是,0.0,0.0,0.0,62.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  800. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-03-07 07:00:00,2026-03-07 08:00:00,2,2,是,0.0,0.0,0.0,90.25,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  801. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-03-07 15:00:00,2026-03-07 17:00:00,3,2,是,0.0,0.0,0.0,61.04,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  802. 9号机,32,YSJ_21,三级1列缸排气温度,三级,1列,停机/通道异常,2026-03-08 05:00:00,2026-03-08 07:00:00,3,2,是,0.0,0.0,0.0,61.64,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  803. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-09 18:00:00,2026-03-09 19:00:00,2,2,是,0.0,0.0,0.0,93.35,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  804. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-03-10 00:00:00,2026-03-10 01:00:00,2,2,是,0.0,0.0,0.0,90.22,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  805. 9号机,32,YSJ_16,一级2列缸排气温度,一级,2列,停机/通道异常,2026-03-13 07:00:00,2026-03-13 08:00:00,2,2,是,0.0,0.0,0.0,93.2,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  806. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-03-23 03:00:00,2026-03-23 04:00:00,2,2,是,0.0,0.0,0.0,91.98,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  807. 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-03-23 04:00:00,2026-03-23 05:00:00,2,2,是,0.0,0.0,0.0,90.5,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  808. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-03-23 18:00:00,2026-03-23 19:00:00,2,2,是,0.0,0.0,0.0,92.72,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  809. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-03-25 15:00:00,2026-03-25 17:00:00,3,2,是,0.0,0.0,0.0,94.09,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  810. 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,停机/通道异常,2026-03-25 15:00:00,2026-03-25 17:00:00,3,2,是,0.0,0.0,0.0,93.43,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  811. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-04-03 15:00:00,2026-04-03 17:00:00,3,2,是,0.0,0.0,0.0,95.49,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  812. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-04-03 21:00:00,2026-04-03 22:00:00,2,2,是,0.0,0.0,0.0,90.68,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  813. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-04-04 04:00:00,2026-04-04 05:00:00,2,2,是,0.0,0.0,0.0,92.37,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  814. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-04-05 22:00:00,2026-04-05 22:00:00,1,1,是,0.0,0.0,0.0,90.6,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  815. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-04-10 12:00:00,2026-04-10 14:00:00,3,2,是,0.0,0.0,0.0,95.42,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  816. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-04-12 08:00:00,2026-04-12 10:00:00,3,2,是,0.0,0.0,0.0,94.59,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  817. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,停机/通道异常,2026-04-12 17:00:00,2026-04-12 18:00:00,2,2,是,0.0,0.0,0.0,93.62,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  818. 9号机,32,YSJ_17,一级4列缸排气温度,一级,4列,停机/通道异常,2026-04-13 21:00:00,2026-04-14 05:00:00,9,4,是,0.0,0.0,0.0,94.9,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  819. 9号机,32,YSJ_18,一级6列缸排气温度,一级,6列,停机/通道异常,2026-04-17 22:00:00,2026-04-17 22:00:00,1,1,是,0.0,0.0,0.0,95.23,单通道突然接近环境温度并恢复,按停机/采集异常处理,不参与温度故障
  820. 9号机,32,YSJ_19,二级3列缸排气温度,二级,3列,通道骤降,2026-04-18 08:00:00,2026-04-18 08:00:00,1,1,否,61.03,61.03,61.03,86.31,单通道短时骤降并恢复,按通道异常处理,不参与同级温差
  821. 9号机,32,YSJ_20,二级5列缸排气温度,二级,5列,通道骤降,2026-04-18 08:00:00,2026-04-18 08:00:00,1,1,否,60.37,60.37,60.37,85.39,单通道短时骤降并恢复,按通道异常处理,不参与同级温差